Fatigue resistance of all-ceramic fixed partial dentures - Fatigue tests and finite element analysis.

S D Heintze1, D Monreal2, M Reinhardt2, A Eser2, A Peschke2, J Reinshagen3, V Rousson4.   

Abstract

OBJECTIVE: To estimate the fatigue resistance of a new translucent zirconia material in comparison to lithium disilicate for 3-unit fixed partial dentures (FPDs).
METHODS: Eighteen 3-unit FPDs (replacement of first upper molar) with a connector size of 4mm×4mm were dry milled with a five-axis milling machine (Zenotec Select, Wieland, Germany) using discs made of a new translucent zirconia material (IPS e.max ZirCAD MT, Ivoclar Vivadent). Another 9 FPDs with a reduced connector size (3mm×4mm) were milled. The zirconia FPDs were sintered at 1500°C. For a comparison, 9 FPDs were made of IPS e.max Press, using the same dimensions. These IPS e.max Press FPDs were ground from a wax disc (Wieland), invested and pressed at 920°C. All FPDs were glazed twice. The FPDs were adhesively luted to PMMA dies with Multilink Automix. Dynamic cyclic loading was carried out on the molar pontic using Dyna-Mess testing machines (Stolberg, Germany) with 2×106 cycles at 2Hz in water (37°C). Two specimens per group and load were subjected to decreasing load levels (at least 4) until the two specimens no longer showed any failures. Another third specimen was subjected to this load to confirm the result. All the specimens were evaluated under a stereo microscope (20× magnification). The number of cycles reached before observing a failure, and their dependence on the load and on the material, were modeled, using a Weibull model. This made it possible to estimate the fatigue resistance as the maximum load for which one would observe less than 1% failure after 2×106 cycles. In addition to the experimental study, Finite Element Modeling (FEM) simulations were conducted to predict the force to failure for IPS e.max ZirCAD MT and IPS e.max Press with a reduced cross-section of the connectors.
RESULTS: The failure mode of the zirconia FPDs was mostly the fracture of the distal connector, whereas the failure mode of the lithium disilicate FPDs observed to be the fracture of the connectors or multiple cracks of the pontic. The fatigue resistance with 1% fracture probability was estimated to be 488N for the IPS e.max ZirCAD MT FPDs (453N for repeated test), 365N for IPS e.max ZirCAD MT FPDs with reduced connector size and 286N for the e.max Press FPDs. All three IPS e.max ZirCAD groups statistically performed significantly better than IPS e.max Press (p<0.001). On the other hand, no significant difference could be established between the two IPS e.max ZirCAD MT3 groups with a 4mm×4mm connector size (p>0.05). The allowable maximum principal stress (σmax) which did not lead to failure during fatigue testing for IPS e.max ZirCAD MT3 was calculated between 208MPa and 223MPa for FPDs with 4mm×4mm connectors for 2×106 cycles. This value could also be verified for the FPDs of the same material with 3mm×4mm connectors. On the other hand fatigue strength in terms of σmax at 2×106 cycles of IPS e.max Press was calculated to be between 78 and 90MPa. SIGNIFICANCE: The fatigue resistance of the translucent zirconia 3-unit FPDs was about 60-70% higher than that of the lithium disilicate 3-unit FPDs, which may justify their use for molar replacements, provided that a minimal connector size of 4mm×4mm is observed. Even with a limited number of specimens (n=9) per group it was possible to statistically differentiate between the tested groups.
Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cyclic loading; FEM; Fatigue resistance; Lithium disilicate; Weibull model; Zirconia

Mesh:

Substances:

Year:  2018        PMID: 29395474     DOI: 10.1016/j.dental.2017.12.005

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  7 in total

1.  Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: A finite element analysis.

Authors:  Mahmood Robati Anaraki; Ali Torab; Taymaz Mounesi Rad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-08-14

2.  Effect of ceramic material type on the fracture load of inlay-retained and full-coverage fixed dental prostheses.

Authors:  Hamid Kermanshah; Fariba Motevasselian; Saeedeh Alavi Kakhaki; Mutlu Özcan
Journal:  Biomater Investig Dent       Date:  2020-03-30

3.  Influence of resin cement on color stability of ceramic veneers: in vitro study.

Authors:  Maryam Hoorizad; Sara Valizadeh; Haleh Heshmat; Seyedeh Farnaz Tabatabaei; Tahereh Shakeri
Journal:  Biomater Investig Dent       Date:  2021-01-28

4.  Impact of the Veneering Technique and Framework Material on the Failure Loads of All-Ceramic Computer-Aided Design/Computer-Aided Manufacturing Fixed Partial Dentures.

Authors:  Sebastian Hinz; Tobias Bensel; Wolfgang Bömicke; Anders Henningsen; Judith Rudolph; Arne F Boeckler
Journal:  Materials (Basel)       Date:  2022-01-19       Impact factor: 3.623

5.  Fracture Load and Fracture Patterns of Monolithic Three-Unit Anterior Fixed Dental Prostheses after In Vitro Artificial Aging-A Comparison between Color-Gradient and Strength-Gradient Multilayer Zirconia Materials with Varying Yttria Content.

Authors:  Max L Pöppel; Martin Rosentritt; Richard Sturm; Florian Beuer; Jeremias Hey; Alois Schmid; Franziska Schmidt
Journal:  J Clin Med       Date:  2022-08-25       Impact factor: 4.964

6.  Influence of Aging on the Fracture Characteristics of Polyetheretherketone Dental Crowns: A Preliminary Study.

Authors:  Wen-Ju Lu; Viritpon Srimaneepong; Chiang-Sang Chen; Chang-Hung Huang; Hui-Ching Lin; Chia-Fei Liu; Her-Hsiung Huang
Journal:  Polymers (Basel)       Date:  2022-10-01       Impact factor: 4.967

7.  Influence of CAD/CAM Milling and 3D-Printing Fabrication Methods on the Mechanical Properties of 3-Unit Interim Fixed Dental Prosthesis after Thermo-Mechanical Aging Process.

Authors:  Passent Ellakany; Shaimaa M Fouda; Amr A Mahrous; Maram A AlGhamdi; Nourhan M Aly
Journal:  Polymers (Basel)       Date:  2022-09-30       Impact factor: 4.967

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.