Literature DB >> 29393010

Comparison of rigid and semi-rigid instrumentation under acute load on vertebrae treated with posterior lumbar interbody fusion/transforaminal lumbar interbody fusion procedures: An experimental study.

Mehmet Reşid Önen1, Cemile Başgül2, İlhan Yılmaz1, Mustafa Özkaya3, Teyfik Demir2, Sait Naderi1.   

Abstract

Rigid and semi-rigid fixations are investigated several times in order to compare their biomechanical stability. Interbody fusion techniques are also preferable for maintaining the sagittal balance by protecting the disk height. In this study, the biomechanical comparison of semi-rigid and rigid fixations with posterior lumbar interbody fusion or transforaminal lumbar interbody fusion procedures is conducted under trauma. There were four different test groups to analyze the effect of acute load on treated ovine vertebrae. First and second groups were fixed with polyetheretherketone rods and transforaminal lumbar interbody fusion and posterior lumbar interbody fusion cages, respectively. Third and fourth groups were fixed with titanium rods and posterior lumbar interbody fusion and transforaminal lumbar interbody fusion cages, respectively. The drop tests were conducted with 7 kg weight. There were six samples in each group so the drop test repeated 24 times in total. The test samples were photographed and X-rayed (laterally and anteroposteriorly) before and after drop test. Two fractures were observed on group 1. Conversely, there were no fractures observed for group 2. There were no anterior element fractures for both groups 1 and 2. However, one fracture seen on group 3 was anterior element fracture, whereas the other three were posterior element fractures. All three fractures were anterior element fractures for group 4. Treated vertebrae with polyetheretherketone rods and posterior lumbar interbody fusion cages showed the best durability to the drop tests among the groups. Semi-rigid fixation gave better results than rigid fixation according to failed segments. Posterior lumbar interbody fusion cages seem to be better option for semi-rigid fixation, however mentioned surgical disadvantages must be considered.

Entities:  

Keywords:  Semi-rigid fixation; compression load; drop mechanism; fracture energy; load sharing; polyetheretherketone rod; posterior fusion; posterior lumbar interbody fusion; rigid fixation; transforaminal lumbar interbody fusion

Mesh:

Year:  2018        PMID: 29393010     DOI: 10.1177/0954411918755416

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  2 in total

1.  Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: a comparison between pedicle screw fixation system with rigid and flexible rods.

Authors:  Wei Fan; Li-Xin Guo; Dan Zhao
Journal:  J Mater Sci Mater Med       Date:  2019-10-18       Impact factor: 3.896

2.  A retrospective controlled study protocol of transforaminal lumbar interbody fusion compared with posterior lumbar interbody fusion for spondylolisthesis.

Authors:  Ping Yi; Xiangsheng Tang; Feng Yang; Mingsheng Tan
Journal:  Medicine (Baltimore)       Date:  2020-10-30       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.