Literature DB >> 29392289

Finite Element Study to Evaluate the Biomechanical Performance of the Spine After Augmenting Percutaneous Pedicle Screw Fixation With Kyphoplasty in the Treatment of Burst Fractures.

Shady S Elmasry1, Shihab S Asfour2, Francesco Travascio3.   

Abstract

Percutaneous pedicle screw fixation (PPSF) is a well-known minimally invasive surgery (MIS) employed in the treatment of thoracolumbar burst fractures (TBF). However, hardware failure and loss of angular correction are common limitations caused by the poor support of the anterior column of the spine. Balloon kyphoplasty (KP) is another MIS that was successfully used in the treatment of compression fractures by augmenting the injured vertebral body with cement. To overcome the limitations of stand-alone PPSF, it was suggested to augment PPSF with KP as a surgical treatment of TBF. Yet, little is known about the biomechanical alteration occurred to the spine after performing such procedure. The objective of this study was to evaluate and compare the immediate post-operative biomechanical performance of stand-alone PPSF, stand-alone-KP, and KP-augmented PPSF procedures. Novel three-dimensional (3D) finite element (FE) models of the thoracolumbar junction that describes the fractured spine and the three investigated procedures were developed and tested under mechanical loading conditions. The spinal stiffness, stresses at the implanted hardware, and the intradiscal pressure at the upper and lower segments were measured and compared. The results showed no major differences in the measured parameters between stand-alone PPSF and KP-augmented PPSF procedures, and demonstrated that the stand-alone KP may restore the stiffness of the intact spine. Accordingly, there was no immediate post-operative biomechanical advantage in augmenting PPSF with KP when compared to stand-alone PPSF, and fatigue testing may be required to evaluate the long-term biomechanical performance of such procedures.

Entities:  

Mesh:

Year:  2018        PMID: 29392289     DOI: 10.1115/1.4039174

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  7 in total

1.  Biomechanical Analysis of Different Internal Fixation Combined with Different Bone Grafting for Unstable Thoracolumbar Fractures in the Elderly.

Authors:  Qisong Shang; Yuqing Jiang; Wenhui Sheng; Pengyuan Han; Junru Zheng; Xing Wang; Bing Wu
Journal:  Biomed Res Int       Date:  2022-04-25       Impact factor: 3.246

2.  Finite element analysis comparing short-segment instrumentation with conventional pedicle screws and the Schanz pedicle screw in lumbar 1 fractures.

Authors:  Fei Zhou; Sheng Yang; Jifeng Liu; Jianmin Lu; Depeng Shang; Chao Chen; Huanhuan Wang; Jinming Ma
Journal:  Neurosurg Rev       Date:  2019-08-02       Impact factor: 3.042

3.  Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis.

Authors:  Hui-Zhi Guo; Shun-Cong Zhang; Dan-Qing Guo; Yan-Huai Ma; Kai Yuan; Yong-Xian Li; Jian-Cheng Peng; Jing-Lan Li; Yong-Chao Tang
Journal:  BMC Musculoskelet Disord       Date:  2020-07-13       Impact factor: 2.362

4.  Biomechanical finite element analysis of vertebral column resection and posterior unilateral vertebral resection and reconstruction osteotomy.

Authors:  Ye Han; Xiaodong Wang; Jincheng Wu; Hanpeng Xu; Zepei Zhang; Kepeng Li; Yang Song; Jun Miao
Journal:  J Orthop Surg Res       Date:  2021-01-28       Impact factor: 2.359

5.  Numerical Comparison of Restored Vertebral Body Height after Incomplete Burst Fracture of the Lumbar Spine.

Authors:  Guan-Heng Jhong; Yu-Hsuan Chung; Chun-Ting Li; Yen-Nien Chen; Chih-Wei Chang; Chih-Han Chang
Journal:  J Pers Med       Date:  2022-02-10

6.  Biomechanical comparison between unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: A finite element analysis.

Authors:  Haowen Dai; Yang Liu; Qing Han; Aobo Zhang; Hao Chen; Yang Qu; Jincheng Wang; Jianwu Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-09-08

7.  Comparison of Percutaneous Kyphoplasty with or without Pedicle Screw Fixation in Osteoporotic Thoracolumbar Vertebral Fractures: A Retrospective Study.

Authors:  Dichao Huang; Jichong Ying; Dingli Xu; Jianming Chen; Jianlei Liu; Tianming Yu; Yunqiang Zhuang; Long Zhou
Journal:  Dis Markers       Date:  2021-06-29       Impact factor: 3.434

  7 in total