Literature DB >> 29390936

Comparison of biliary brush biopsy and fine needle biopsy in the diagnosis of biliary strictures.

Adrian Gonzalez-Aguirre1, Anne M Covey1, Karen T Brown1, Lynn A Brody1, F Edward Boas1, Constantinos T Sofocleous1, Majid Maybody1, George I Getrajdman1, Joseph P Erinjeri1.   

Abstract

PURPOSE: The purpose of this study is to evaluate the accuracy of percutaneous fine needle biopsy (FNB) and brush biopsy (BB) at a cancer center.
MATERIAL AND METHODS: Retrospective analysis of all bile duct biopsies performed in Interventional Radiology between January 2000 and January 2015 was performed. FNB was performed under real-time cholangiographic guidance using a notched needle directed at the bile duct stricture. BB was performed by advancing a brush across the stricture and moving it back and forth to scrape the stricture. Biopsy results were categorized as true positive (TP), true negative (TN), false positive (FP) and false negative (FN) based on pathology reports and confirmed by surgical specimens or clinical follow-up of at least six months. Fisher's exact test was used to compare the rate of TP in FNB and BB.
RESULTS: One-hundred and nineteen patients underwent FNB or BB. Fifteen were censored because of lack of follow-up. The remaining 104 patients underwent a total of 117 bile duct biopsies during the study period: 34 FNB and 83 BB. There were no complications in either group. In the FNB group 22/34 (64%) biopsies were TP, 4/34(12%) were TN and there were 8(24%) FN biopsies. In the BB group, 20/83 (24%) were TP, 38/83 (46%) TN and 25/83 (30%) FN biopsies. There were no FP biopsies in either group. The sensitivity of detecting malignancy by FNB was significantly higher than that by BB (73% vs 44%, p < .0005). There were no complications associated with FNB or BB.
CONCLUSIONS: FNB of bile duct strictures is safe and has a higher sensitivity for detecting malignancy than BB.

Entities:  

Keywords:  Image-guided procedures; bile duct stricture; interventional radiology; percutaneous biopsy

Mesh:

Year:  2018        PMID: 29390936     DOI: 10.1080/13645706.2018.1427597

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  2 in total

Review 1.  Treatment of Malignant Bile Duct Obstruction: What the Interventional Radiologist Needs to Know.

Authors:  Juan C Camacho; Lynn A Brody; Anne M Covey
Journal:  Semin Intervent Radiol       Date:  2021-08-10       Impact factor: 1.780

2.  Intraductal Tissue Sampling Device Designed for the Biliary Tract.

Authors:  Malay S Patel; Matthew D Carson; Eric J Seibel; Lucas R Meza
Journal:  IEEE J Transl Eng Health Med       Date:  2021-02-04       Impact factor: 3.316

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.