Dengfa Yang1, Jianmin Shen1, Xianwu Xia1, Yeqing Lin1, Tiejun Yang1, Hanshun Lin1, Yong Jin2, Kaiyu Zhou2, Youcheng Li3. 1. 1 Department of Radiology, Taizhou Municipal Hospital , Taizhou, Zhejiang , China. 2. 2 Department of Neurological Surger, Taizhou Municipal Hospital , Taizhou, Zhejiang , China. 3. 3 Department of Radiology, The First Affiliated Hospital of Wenzhou Medical University , Wenzhou, Zhejiang , China.
Abstract
OBJECTIVE: The purpose of the study was to evaluate the value of high-resolution three-dimensional fast low angle shot (3D-FLASH) and three-dimensional constructive interference in steady-state (3D-CISS) MRI sequence solely or the combination of both in the visualization of neurovascular relationship in patients with trigeminal neuralgia (TN). METHODS: 65 patients with unilateral TN underwent 3D-FLASH and 3D-CISS imaging were retrospectively studied. Neurovascular relationship at the intracisternal segment of trigeminal nerve was reviewed by two experienced neuroradiologist, who was blinded to the clinical details. The imaging results were compared with the operative findings in all patients. RESULTS: The accuracy and positive rates of the 3D-FLASH + CISS imaging (98.46, 92.31%) in judging the symptomatic side according to the presence of vascular contacts were higher than those of 3D-CISS (90.77%, 84.62) or 3D-FLASH (89.23, 83.08%) sequence. In addition, the statistical analysis showed the sensitivity and accuracy of 3D-FLASH + CISS imaging was higher than that of 3D-FLASH (p < 0.05). The 3D-FLASH + CISS imaging was more accurate in determining the type of offending vessel than 3D-CISS or 3D-FLASH imaging. CONCLUSION: The retrospective study demonstrates that the combination of 3D-FLASH with 3D-CISS sequence well delineates the relationship between intracisternal segment of trigeminal nerve and adjacent vessels in terms of increased positive rates and accuracy. Advances in knowledge: The study firstly dealt with the combination of 3D-CISS and 3D-FLASH imaging in TN.
OBJECTIVE: The purpose of the study was to evaluate the value of high-resolution three-dimensional fast low angle shot (3D-FLASH) and three-dimensional constructive interference in steady-state (3D-CISS) MRI sequence solely or the combination of both in the visualization of neurovascular relationship in patients with trigeminal neuralgia (TN). METHODS: 65 patients with unilateral TN underwent 3D-FLASH and 3D-CISS imaging were retrospectively studied. Neurovascular relationship at the intracisternal segment of trigeminal nerve was reviewed by two experienced neuroradiologist, who was blinded to the clinical details. The imaging results were compared with the operative findings in all patients. RESULTS: The accuracy and positive rates of the 3D-FLASH + CISS imaging (98.46, 92.31%) in judging the symptomatic side according to the presence of vascular contacts were higher than those of 3D-CISS (90.77%, 84.62) or 3D-FLASH (89.23, 83.08%) sequence. In addition, the statistical analysis showed the sensitivity and accuracy of 3D-FLASH + CISS imaging was higher than that of 3D-FLASH (p < 0.05). The 3D-FLASH + CISS imaging was more accurate in determining the type of offending vessel than 3D-CISS or 3D-FLASH imaging. CONCLUSION: The retrospective study demonstrates that the combination of 3D-FLASH with 3D-CISS sequence well delineates the relationship between intracisternal segment of trigeminal nerve and adjacent vessels in terms of increased positive rates and accuracy. Advances in knowledge: The study firstly dealt with the combination of 3D-CISS and 3D-FLASH imaging in TN.
Authors: Paulo Roberto Lacerda Leal; Marc Hermier; Miguel Angelo Souza; Gerardo Cristino-Filho; Jean Claude Froment; Marc Sindou Journal: Neurosurgery Date: 2011-07 Impact factor: 4.654
Authors: Valerie C Anderson; Phillip C Berryhill; Michael A Sandquist; David P Ciaverella; Gary M Nesbit; Kim J Burchiel Journal: Neurosurgery Date: 2006-04 Impact factor: 4.654