Literature DB >> 29377190

Human placental oxygenation in late gestation: experimental and theoretical approaches.

Gareth A Nye1,2, Emma Ingram1,2, Edward D Johnstone1,2, Oliver E Jensen3, Henning Schneider4, Rohan M Lewis5, Igor L Chernyavsky1,2,3, Paul Brownbill1,2.   

Abstract

The placenta is crucial for life. It is an ephemeral but complex organ acting as the barrier interface between maternal and fetal circulations, providing exchange of gases, nutrients, hormones, waste products and immunoglobulins. Many gaps exist in our understanding of the detailed placental structure and function, particularly in relation to oxygen handling and transfer in healthy and pathological states in utero. Measurements to understand oxygen transfer in vivo in the human are limited, with no general agreement on the most appropriate methods. An invasive method for measuring partial pressure of oxygen in the intervillous space through needle electrode insertion at the time of Caesarean sections has been reported. This allows for direct measurements in vivo whilst maintaining near normal placental conditions; however, there are practical and ethical implications in using this method for determination of placental oxygenation. Furthermore, oxygen levels are likely to be highly heterogeneous within the placenta. Emerging non-invasive techniques, such as MRI, and ex vivo research are capable of enhancing and improving current imaging methodology for placental villous structure and increase the precision of oxygen measurement within placental compartments. These techniques, in combination with mathematical modelling, have stimulated novel cross-disciplinary approaches that could advance our understanding of placental oxygenation and its metabolism in normal and pathological pregnancies, improving clinical treatment options and ultimately outcomes for the patient.
© 2018 University of Oxford. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.

Entities:  

Keywords:  FGR; MRI; intervillious space; modelling; oxygen; perfusion; placenta

Mesh:

Substances:

Year:  2018        PMID: 29377190      PMCID: PMC6265570          DOI: 10.1113/JP275633

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


Introduction

The placenta is vital for fetal growth and development, adapting its physiology, architecture and signalling throughout gestation to meet changing demands. Despite this, there remain many unanswered questions in our detailed understanding of placental structure, function and transfer efficacy in both normal and diseased states in utero. It is an ephemeral but complex organ acting as the interface between mother and fetus, providing a hub for exchange. One of the key functions of the placenta is to mediate transfer of oxygen to the fetus. However, there is poor consensus on the oxygenation of placental compartments, most notably oxygen gradients within the intervillous space (IVS) of the maternal circulation, and how the partial pressure of this gas () differs between normal pregnancies and those complicated by placental diseases. A full understanding of spatio‐temporal oxygenation and associated placental villous architecture in healthy and diseased states, aiding mathematical model development on transplacental oxygen transfer, will ultimately be useful to obstetricians trying to understand and treat placental disease. In this review, we will present current views on human placenta structure and function with respect to oxygen transfer. This will include discussions on the strengths and weaknesses of the current methods used to measure placental oxygenation both in vivo and ex vivo. It will also summarise reported oxygen levels within the placenta–fetal unit, with an emphasis on dysregulated materno‐fetal oxygen transfer in pregnancy pathologies.

Placental structure and function

The human placenta is a discoid haemomonochorial dually perfused organ, which in a healthy term pregnancy has a mean mass of 650 g and a surface area for exchange of 13 m2 (Mayhew et al. 2007). It contains 25% (80 mL) of the total fetal blood volume (Luckhardt et al. 1996). Fetal blood flow from the two umbilical arteries is forced through two elaborately branched networks across the chorionic plate before delving into the placental mass where they branch again entering approximately 50 placental villous trees. Several villous trees might occupy a single lobule, which is the semi‐compartmentalised structure defined by septa as seen from the basal plate aspect. Villous trees are elaborately branched, commencing with stem villi (Leiser et al. 1985). Stem villi divide extensively to form intermediate villi, with the mature type branching off to form the terminal villi (Kaufmann et al. 1985). In later pregnancy, having arrived at the villous capillaries via an arteriolar microcirculatory system, the fetoplacental capillary blood enriched with oxygen and nutrients is forced into the venular systems of the mature intermediate and stem villi, and then into veins on the chorionic plate, subsequently travelling to the fetus via a single umbilical vein. Architectural events unfold in the developing placenta throughout gestation to arrive at the position of mature villous trees capable of servicing the ever‐increasing demand of the fetus for oxygen. See e.g. Huppertz (2008) and Wang and Zhao (2010) for the detailed anatomy and physiology of the human placenta and its developmental aspects. During the third trimester, terminal villi formation increases exponentially (Risau & Rubanyi, 2000). From 24 to 26 weeks of gestation, branching angiogenesis ensues, leading to capillary outgrowths and the maturation of intermediate villi. Capillary loops are hypothesised to dilate and remodel laterally under transmural hydrostatic pressure between the fetal and maternal placental circulations (Burton et al. 1996). Furthermore, fetal and maternal blood are brought into close proximity at specialised adaptive capillary structures known as vasculosyncytial membranes. These represent a thinning of the combined fetoplacental endothelium and syncytialised trophoblast, with extensive lateral displacement of single‐celled trophoblasts and membrane‐associated organelles (Castellucci et al. 1990). This structural adaptation confines the endo‐epithelial placental barrier to a diffusion distance of 2–3 μm, an important facet of Fick's law of diffusion, appertaining more particularly to the efficiency of transfer of hydrophilic molecules (Sibley et al. 1998), but also in part to fast diffusing gases like oxygen. The pathway of blood between the placenta and fetus with compartmentalised reported oxygen ranges in late pregnancy has been summarised for the purpose of this review in Fig. 1.
Figure 1

Simplified schematic diagram of the maternal and fetal placental circulations, showing the major compartments and published attributed in vivo oxygen values (see Table 1)

 

Simplified schematic diagram of the maternal and fetal placental circulations, showing the major compartments and published attributed in vivo oxygen values (see Table 1)

Although the placenta is involved in essential functions to maintain fetal health, little is known about how human placenta transfer in vivo relates to fetal oxygen acquisition in the human. The placenta is dynamic, with the capability of adapting to possible net reductions in maternal blood flow, ensuring there is an adequate supply of oxygen to the fetus (Wilkening & Meschia, 1983). In vivo work using animal models, most notably the sheep, shows a normal tolerance to reduced maternal‐side placental blood flow, before placental metabolic demands out‐compete fetal demands for oxygen provision from the maternal circulation (Gu et al. 1985). The work of Gu, who collaborated with Professor Julian Parer whilst he was at the University of California, showed that a reduction in uterine artery blood flow by up to 30% had no effect on fetal oxygenation levels (Gu et al. 1985). Whilst the anatomy of the sheep placenta is substantially different to the human placenta, broader concepts such as hypoxic fetoplacental vasoconstriction and the possible role of oxygen‐sensitive voltage‐gated potassium channels in this process, as found in humans, might provide a cross‐species mechanism by which feto‐maternal blood flow matching could arise (Byrne et al. 1997; Hampl et al. 2002; Kiernan et al. 2010). Modern in vivo imaging, ex vivo placental spatial oxygen mapping technology and mathematical modelling are now available to investigate these early observations and aim to unravel the intricacies of how fetal oxygen acquisition is regulated by placental structure and function in health and disease. This multidisciplinary approach has shown the impact of sinusoidal capillaries on placental function (Pearce et al. 2016; Plitman Mayo et al. 2016b) where mathematical modelling indicates the existence of an optimal capillary dilatation size that maximises oxygen uptake. A fuller understanding of the remaining aspects of the placental oxygen transfer in health and disease now seems possible.

Oxygen metabolism and levels within the human placenta

In the placenta, gases diffuse due to partial pressure gradients which are maintained by maternal and fetal blood flow. As diffusion of gases across the placenta is rapid, placental gas transfer is flow limited (Meschia et al. 1967). Oxygen transfer depends on a partial pressure gradient being present between the maternal blood in the intervillous space (IVS) and the fetal blood in the fetoplacental capillaries and is enhanced by the Bohr–Haldane effect: as maternal blood takes up fetal carbon dioxide and becomes acidotic, oxygen release to the fetus is favoured. Simultaneously fetal blood takes up oxygen while decreasing its storage capacity for carbon dioxide and releasing it into the maternal circulation (Pinnock et al. 2002). Additionally, there is a higher affinity of the fetal haemoglobin for oxygen, fetal haemoglobin containing two α and two γ subunits compared to maternal haemoglobin which has two α and two β subunits. When considering oxygen levels within the placenta, the differing compartments need to be viewed separately. The normal range for oxygenation of adult blood is between 75 and 100 mmHg. Although there may be a slight reduction in this during pregnancy, it is not expected to differ greatly. IVS soluble oxygenation values are expected to be reduced by the metabolic demand of placental tissue and the transfer to the fetal circulation. It is known that 40% of the total oxygen consumption occurs in the syncytiotrophoblast layer (Carter, 2000). However, where there is failure of spiral arteries to transform to a wider aperture, this potentially leads to altered haemodynamics, with a reduced net IVS flow, more localised blood flow patterns, and disparate skewed oxygen gradients around placental villi (Burton et al. 2009). This in turn ultimately leads to placental dysfunction and disease.

Poor placental oxygenation – a trigger for placental dysfunction

The placenta is developed to maximise the transfer of gases and nutrients to aid the growth of the fetus. When this fails, a wide range of maternal and fetal complications can occur, one of the most common complications being fetal growth restriction (FGR) where the fetus fails to reach its genetic growth potential. Over half of neonatal deaths worldwide are associated with low birth weight (UNICEF, 2004). Surviving FGR neonates face developmental problems and an increased risk of cardiovascular diseases in later life. There are many causes of FGR involving both maternal and placental factors (Sharma et al. 2016). One key factor is a reduction in oxygen transfer to the baby. Placentas measured from FGR babies are on average 24% smaller in weight than normal pregnancies (Heinonen et al. 2001). In the absence of genetic abnormalities and underlying maternal conditions, this suggests a reduced functional capacity of the placenta. One hypothesised aetiology is a reduced placental surface area for gas exchange, coupled with dysregulated placental blood flow, leading to suboptimal oxygen transfer from maternal to fetal circulations (Yu, 1992). An alternative aetiology is that dysregulated placental morphology might also reduce the oxygen transfer across the placenta. Non‐placental aetiologies relate to maternal lifestyle factors which include smoking, living at high altitude and heart or lung disease, all of which depress the in the maternal circulation, diminishing placental oxygen transfer (Sharma et al. 2016). In such low oxygen environments, as found in some cases of FGR, it should be borne in mind that placental metabolism might shift to a high glucose and low oxygen consumption mode, which could have a bearing on relative oxygen transfer rates to the fetus. This indirect evidence comes from an analogous study of high altitude pregnancies, referring to a reduced maternal oxygen supply to the placenta (Zamudio et al. 2010). Conversely, Kingdom et al. proposed processes whereby changing oxygen levels can alter the structure of capillarisation within the terminal villous tree (Kingdom et al. 2000). Potentially this can compound an already compromised disturbance in , further reducing oxygenation of the fetal circulation. The hypothesis remains to be tested that compromised villous tree architecture coupled with existing reduced oxygen levels in the maternal circulation exceeds a critical threshold leading to FGR. A comprehensive study including mathematical modelling of complex placental architecture, coupled with ex vivo physiological perfusion experimentation and in vivo magnetic resonance imaging (MRI), will provide further answers. This may then permit an interrogation of transplacental transfer efficacy of oxygen, providing translational tools for obstetricians in their diagnosis and management of FGR associated with oxygen transfer deficiency.

Current understanding of placental oxygen levels

As discussed previously, the in vivo measurement of placental oxygen has proved difficult and has only been recorded in a handful of studies. Schaaps et al. published the most recent cross‐sectional study (Schaaps et al. 2005) using IVS blood sampling which was achieved through insertion of a 21 gauge needle through the chorionic plate, with blood being collected once the baby was delivered, but before the placenta was expelled (Schaaps et al. 2005). This had previously been done in 1960 by Quilligan et al. and again in 1996 by Fujikura & Yoshida, who both recorded lower average values. The Schaaps paper also published a ratio between the uterine vein and the IVS of 1.5 (Schaaps et al. 2005). Using this ratio, values of 50 mmHg in the uterine vein (Sibley et al. 2002) would lead to an approximate IVS value of 33 mmHg. With near infrared spectroscopy, Kakogawa et al. (2010) predicted an IVS value of 30 mmHg. Although providing the best‐available estimate of IVS , caution must be applied to the uterine vein–IVS ratio extrapolator. The ratio first appears counterintuitive, since uterine vein blood occurs downstream of the IVS. However, arteriovenous placental shunting and preferential IVS flow pathways evading measurement may lead to higher than expected uterine vein oxygen values. Ideally, further ubiquitous IVS real‐time data must be sought before relying solely on this reported ratio. The few studies recording IVS oxygenation in term placentas show a value of approximately 36 mmHg. This is much lower than the of peripheral maternal arterial blood, which does not drop below 100 mmHg throughout gestation (Templeton & Kelman, 1976), potentially indicating transfer loss and a highly metabolic cellular layer of the IVS. Compartmentalised in vivo values of soluble human placental oxygenation are given in Fig. 1 and corresponding published values are summarised in Table 1. A small reduction in the oxygen levels between the IVS and the umbilical vein is evident with an average IVS oxygen recording of 30 mmHg and a further reduction in values between the umbilical vein and arteries (22 mmHg). However, there is much greater variation in the recorded values in both measures potentially due to different experimental methods. In particular, there are differences in practice regarding clamping of the umbilical cord after delivery. As shown in Table 1, other studies measuring both venous and arterial values from the same cord recorded similar reductions in the arterial values (Nicolaides et al. 1989; Link et al. 2007). The venous oxygen level recorded by Schaaps et al. is somewhat lower than other recorded values and lower than the average value by 10 mmHg, which is possibly due to the measurement of unclamped cords influencing the oxygen value (Schaaps et al. 2005). It is expected that cord clamping will yield results closer to peripartum levels, due to cord samples being compartmentalised away from the highly metabolic placental tissue.
Table 1

In vivo IVS and ex vivo umbilical artery and vein values in term normal human placentas

PO2 valuesa (no. of samples)Type of measurementTime of measurementReference
Pre‐partum IVS34 (n = 4)18 gauge needleBefore placental shedding(Quilligan et al. 1960)
30 (n = 12)21 gauge needleBefore placental shedding(Fujikura & Yoshida, 1996)
Post‐partum IVS49 (n = 12)18 gauge needleN/A(Haruta et al. 1986)
33 (n = 6)Uterine vein analysisPost placental shedding(Sibley et al. 2002)
29 (n = 9)21 gauge needle(Schaaps et al. 2005)
30 (n = 15)Uterine vein analysis(Kakogawa et al. 2010)
Range 29–49
Weighted mean ± SD 34 ± 9
Umbilical artery28 (n = 53)CordocentesisBefore Caesarean section(Nicolaides et al. 1989)
18 (n = 681)N/APost placental shedding(Dudenhausen et al. 1997)
21 (n = 60)21 gauge needle(Daniel et al. 1998)
30 (n = 18)Blood gas analyser(Ochiai et al. 1999)
16 (n = 1281)N/A(Arikan et al. 2000)
19 (n = 46)N/A(Link et al. 2007)
26 (n = 60)N/A(Fardiazar et al. 2013)
23 (n = 46)N/A(Di Tommaso et al. 2014)
Range 16‐30
Weighted mean ± SD 18 ± 4
Umbilical vein35 (n = 14)Before Caesarean section(Pardi et al. 1987)
43 (n = 143)Cordocentesis(Nicolaides et al. 1989)
31 (n = 60)21 gauge needlePost placental shedding(Daniel et al. 1998)
18 (n = 18)Blood gas analyser(Ochiai et al. 1999)
19 (n = 9)21 gauge needle(Schaaps et al. 2005)
25 (n = 46)N/A(Link et al. 2007)
29 (n = 300)N/A(Bernardez‐Zapata & Moreno‐Rey, 2014)
27 (n = 46)N/A(Di Tommaso et al. 2014)
Range 19–43
Weighted mean ± SD 32 ± 8
Uterine artery97 (n = 50)ElectrodePost placental shedding(Blechner et al. 1968)
147 (n = 18)Blood gas analyser(Ochiai et al. 1999)
91 (n = 168)(Postigo et al. 2009)
Range 91–147
Weighted mean ± SD 97 ± 22
Uterine vein33ElectrodePost placental shedding(Stave, 1970)
50 (n = 6)Blood gas analyser(Sibley et al. 2002)
46 (n = 10)21 gauge needleBefore placental shedding(Fujikura & Yoshida, 1996)
Range 33–50

values are in mmHg. N/A, not available. Cross‐study values are presented as range and mean ± SD, weighted with the sample size.

In vivo IVS and ex vivo umbilical artery and vein values in term normal human placentas values are in mmHg. N/A, not available. Cross‐study values are presented as range and mean ± SD, weighted with the sample size.

Measuring and modelling oxygen transfer function in the human placenta

Assessing function through in vivo electrodes

A reported method for analysing placental oxygen status of the IVS is through the insertion of a needle into the placental tissue during routine Caesarean sections (Quilligan et al. 1960; Fujikura & Yoshida, 1996) (Table 1). Although this allows for direct measurement in vivo whilst still under normal conditions, there is a sampling efficiency problem due to the limited number of IVS measurements that can realistically be taken during surgery in such a large tissue. The heterogeneity of levels within the IVS and the potential for contamination of IVS samples from disruption of the fetal capillaries are also major problems with this early method. However, there have been recent moves towards in vivo techniques to measure oxygen more ubiquitously in the human placenta.

Assessing function through magnetic resonance imaging

MRI techniques have demonstrated the ability to measure non‐compartmentalised changes in oxygen levels within defined placental spatial parameters. One such technique, blood‐oxygen‐level‐dependent (BOLD) MRI (Fig. 2 A), can effectively measure changes in placental oxygen saturation following a maternal oxygen challenge. Deoxyhaemoglobin acts as an endogenous contrast agent, due to the differing magnetic properties of both oxyhaemoglobin and deoxyhaemoglobin. Changes in oxygen saturation, and therefore deoxyhaemoglobin levels, alter the local magnetic field susceptibility, thus affecting transverse relaxation times and BOLD signal. The first human placental BOLD MRI study (Sorensen et al. 2013) described results from eight women with uncomplicated singleton pregnancies at 28–36 weeks’ gestation. An increased BOLD signal was detected in areas proximal to the chorionic plate of the placenta. However, the potential application of BOLD in placental pathology is uncertain with conflicting data concerning FGR pregnancies in early comparative studies (Ingram et al. 2017). The interpretations of BOLD signal changes is complex due to its relation to haemoglobin concentration and potential oxygen‐related changes in local perfusion. The signal is also potentially affected by undetected uterine activity and there is a tendency for BOLD signal intensity to be correlated more closely with fetal haemoglobin oxygen saturation than with maternal haemoglobin oxygen saturation. This may be due to the relative hypoxic condition of the normal fetus, which results in a significant BOLD signal change, with changes in oxygen concentration, operating along the exponential phase of the sigmoidal fetal haemoglobin oxygen association curve.
Figure 2

Measuring oxygen distribution in the human placenta

A, demonstrating a normal placenta imaged using oxygen‐enhanced (OE) MRI techniques. This shows an axial T2‐weighted structural MR image through maternal abdomen at the level of the uterine cavity (circled in blue) demonstrating: fetal abdominal cross‐section (circled in white) and placental region of interest (circled in red) with a superimposed delta R1 map. The colour gradient voxels in the dR1 map demonstrate the differing change in across the placenta following maternal hyperoxia. B, soluble oxygen measurement of the perfusate in the maternal‐side arterial inflow line and the IVS in the ex vivo dually perfused placental lobule, measured via a pre‐IVS oxygen chamber (flow‐through cell) and via an optode needle inserted into the placental tissue, respectively. C, a close‐up image showing the insertion points of both the maternal cannula (i.d. = 2 mm, super‐glued into position to form a seal with the decidua) and the IVS oxygen optode needle inserted through the decidual surface of the placenta.

Measuring oxygen distribution in the human placenta

A, demonstrating a normal placenta imaged using oxygen‐enhanced (OE) MRI techniques. This shows an axial T2‐weighted structural MR image through maternal abdomen at the level of the uterine cavity (circled in blue) demonstrating: fetal abdominal cross‐section (circled in white) and placental region of interest (circled in red) with a superimposed delta R1 map. The colour gradient voxels in the dR1 map demonstrate the differing change in across the placenta following maternal hyperoxia. B, soluble oxygen measurement of the perfusate in the maternal‐side arterial inflow line and the IVS in the ex vivo dually perfused placental lobule, measured via a pre‐IVS oxygen chamber (flow‐through cell) and via an optode needle inserted into the placental tissue, respectively. C, a close‐up image showing the insertion points of both the maternal cannula (i.d. = 2 mm, super‐glued into position to form a seal with the decidua) and the IVS oxygen optode needle inserted through the decidual surface of the placenta. In addition to BOLD MRI, effective changes in tissue have been determined using a complementary technique, oxygen‐enhanced (OE) MRI. In OE MRI, changes in longitudinal relaxation rates (R1) occur due to an increase in the paramagnetic dissolved oxygen content in the tissue with maternal hyperoxia. An increase in R1 following maternal hyperoxia, reflecting an increase in , was first demonstrated in the placenta in 2013 (Huen et al. 2013). Increases in R1 following hyperoxia diminish with gestational age, which is thought to be a consequence of rapid materno‐fetal O2 transfer and utilisation. Additionally, in pregnancies affected by FGR, R1 changes are significantly lower presumably demonstrating a relative placental hypoxia as more of the dissolved oxygen is bound to deoxyhaemoglobin (Ingram et al. 2017). The benefit of these techniques are their non‐invasive nature; however, they are limited in availability and expensive (Sorensen et al. 2013). Essentially these techniques provide measures of relative change in tissue oxygen status. However, these techniques cannot provide absolute or saturation values without further phantom validation. Understanding placental blood flow rates is also important in deciphering placental oxygen transfer efficacy. Within in vivo imaging capability, several options might be available to the researcher in appreciating flow: dynamic contrast enhanced imaging (DCE) (Marcos et al. 1997), arterial spin labelling (ASL) (Gowland et al. 1998) and phase contrast imaging (Jansz et al. 2010). DCE MRI provides spatial images of villous capillary (fetal) and IVS (maternal) flow. Substances such as Omniscan (a gadolinium chelate) are unstable and therefore potentially toxic when used in vivo and have not been characterised for vascular leakage and signal stability. They therefore are only suited for ex vivo perfusions or acute animal experiments. These validations are essential in proving that acquired flow signals are truly compartmentalised. The future research agenda in placenta MRI is optimization of acquisition techniques and combining MRI approaches, such as OE with ASL, to fully characterise the placenta. In ASL, blood is intrinsically labelled, avoiding the concerns of exogenous contrast agents, and therefore this technique has been used in vivo to determine placental flow; however, to date, ASL has been performed on a placental region‐of‐interest which incorporates both maternoplacental and fetoplacental compartments (Shao et al. 2017). ASL quantifies flow per gram of tissue mass but the technique is hampered by poor signal‐to‐noise ratio and the few studies that have been performed demonstrate considerable variation in derived normal values. Whilst functional MRI (fMRI) may be of benefit through the measurement of placental perfusion and oxygen status, its use in the placenta is still limited by a lack of data and there are no accepted MRI‐based definitions of normal/abnormal placental tissue flow rates (Avni et al. 2015). Again, this could be due to differences in cost and availability but also through a lack of consensus on protocols, and poor image quality due to the challenges of correcting for maternal and fetal motion. However, these MRI techniques could be exploited ex vivo, through phantom perfusion investigations, utilising the human dual placental perfusion model to quantify flow and validate in vivo perfusion measures, improving our understanding of the imaging response as a proxy to tissue oxygenation.

Assessing function through ex vivo placental perfusion

There is a limited capability to manipulate in vivo physiological variables during human pregnancy. In this stance, the utilisation of ex vivo physiological research techniques is now coming to the fore. Ex vivo dual perfusion of the human placenta is now a widely used system for investigating a range of pharmacological and physiological functions including drug transfer whilst maintaining placental structure and an approximate in vivo state (Fig. 2 B). Perfusion has advantages over cell culture, tissue slices and explant studies due to the maintenance of villous architecture and relative IVS volume density (Brownbill et al. 2018). Vascularised fetoplacental and IVS perfusate flows are key features of the model in which the placental tissue maintains a higher metabolic level than in other human placental models (Hauguel et al. 1983). This technique involves isolating a whole placental cotyledon from a freshly delivered placenta. The fetal side is cannulated on both arterial and venous sides and either near‐anoxic blood or physiological buffer is pumped through the villous microcirculation (Schneider & Huch, 1985). The maternal side is also supplied with blood or physiological buffer at normoxic or superoxic levels. [53, 54] Flow rates of perfusate are similar to, but less than, in vivo conditions (fetal side, 6 mL min−1) to reduce the overall resistance encountered during the experiment. Placental blood flow on the fetal side is calculated to be approximately 0.35 mL min g−1 in vivo at term, based on the placenta receiving 40% of fetal left ventricular output, being 480 mL min−1 at term. This compares to an ex vivo fetal‐side flow of 0.17 mL min−1 based on a perfused tissue mass of 35 g being perfused at 6 mL min−1 (Desforges et al. 2017). Once perfusion is established, a number of experiments can be undertaken that are not possible in vivo. Examples include increasing or decreasing the flow rate of either fetal or maternal perfusate, introducing drugs such as vasodilators/constrictors, or multiple sampling to monitor perfusate gases. There are disadvantages however: there is a high preparation failure rate; it is reasonably expensive and time‐consuming to run an experiment; and only one lobule from each placenta is usually suitably intact for perfusion, preventing parallel control investigations. To simplify our understanding of placental oxygen transfer, a new adapted version of this model is being trialled by our laboratory. This involves scaling down the established maternal‐side multi‐cannula dual perfusion model, so that the IVS irrigation volume is limited, employing just one maternal cannula delivering normoxic perfusate and measuring oxygen gradients within the IVS (Fig. 2 B). Unlike in vivo oxygen sampling, extensive IVS oxygen sampling under steady‐state experimental conditions is possible by means of an oxygen‐sensitive needle optode inserted through the decidual plate at set X–Y–Z planes controlled with a micromanipulator (Fig. 2 B). With further experimentation the placental metabolic component of IVS oxygen consumption can be elucidated. IVS oxygen gradient data can be acquired and interrogated for metabolism and transfer, and it may be possible to discover how variable perfusate flow rates and fetoplacental vasoactive endocrine agents affect fetal‐side oxygen acquisition, gaining an understanding of how the associated underlying villous architecture enhances or constrains oxygen transfer across the placental barrier. Post‐perfused human placental tissue can be successfully imaged using wholemount confocal and light sheet microscopy. These 3‐D approaches confer advantages over traditional 2‐D techniques such as transmission‐electron and phase‐contrast microscopy (Fig. 3 A), and allow the surface of the villi and the fetal vascular system to be differentially labelled (Fig. 3 B and C). However, these higher‐resolution approaches are only able to image smaller regions of tissue. Micro‐computed tomography (MicroCT) allows the visualisation of larger regions of placental villi placenta but at different scales (Fig. 3 D). Imaging of the fetoplacental vascular system can be enhanced by perfusing contrast agents into the fetal circulation to image the arterial and venous circulation (Junaid et al. 2017). From this, information on vessel branching patterns, interbranching length and capillary loop dilatations are useful in predicting the placenta's ability to optimally transfer oxygen, a portion of the placenta often inaccessible by other means (Junaid et al. 2017). However, while microCT can image large regions of tissue, when doing this its ability to image the microcirculation is limited. MicroCT imaging of fetoplacental capillaries is possible but in smaller pieces of tissue.
Figure 3

Evaluating imaging techniques for use in assessing placental structure

A, a transmission electron micrograph of terminal villi showing microvillous membrane (MVM), an underlying capillary (CAP), a syncytiotrophoblast (S), a trophoblast (T) and endothelium (E). B, projection of an imaged stack (wholemount confocal microscopy), stained with lectin FITC‐AAL for the endothelium (green), rhodamine‐PSA for the stroma (red) and biotin‐DSL for the trophoblast (violet); the DSL was detected with streptavidin 680 and imaging was on a Leica Sp5 confocal microscope, presented as an image stack. C, villous microcirculation of a term normal placenta perfused with a Ulex Europaeus Agglutinin (UEA) lectin linked to biotin and detected with streptavidin 800. D, microCT image of a vascular corrosion cast of a term placenta, infused through the umbilical artery with Batson's resin, which was then set, followed by tissue corrosion steps for several days in 20% (w/v) potassium hydroxide.

Evaluating imaging techniques for use in assessing placental structure

A, a transmission electron micrograph of terminal villi showing microvillous membrane (MVM), an underlying capillary (CAP), a syncytiotrophoblast (S), a trophoblast (T) and endothelium (E). B, projection of an imaged stack (wholemount confocal microscopy), stained with lectin FITC‐AAL for the endothelium (green), rhodamine‐PSA for the stroma (red) and biotin‐DSL for the trophoblast (violet); the DSL was detected with streptavidin 680 and imaging was on a Leica Sp5 confocal microscope, presented as an image stack. C, villous microcirculation of a term normal placenta perfused with a Ulex Europaeus Agglutinin (UEA) lectin linked to biotin and detected with streptavidin 800. D, microCT image of a vascular corrosion cast of a term placenta, infused through the umbilical artery with Batson's resin, which was then set, followed by tissue corrosion steps for several days in 20% (w/v) potassium hydroxide.

Integrating structure and function relationships through modelling

The increased availability of 3‐D imaging approaches, including confocal microscopy and microCT, have made possible the recent increase in efforts to build multiscale computational models that go hand‐in‐hand with refined experimental models (Pearce et al. 2016; Plitman Mayo et al. 2016a; Perazzolo et al. 2017; Roth et al. 2017) (Fig. 4). In tissues with complex structures such as the human placenta, computational modelling has allowed the full structure to be visualised and analysed, facilitating assessment of structure–function relationships (Clark et al. 2015; Plitman Mayo et al. 2016a) (Fig. 4 A). Mathematical models have also been created to explain properties of the placenta that it would not be possible to understand using in vivo measurements alone (Chernyavsky et al. 2011; Serov et al. 2015; Pearce et al. 2016) (Fig. 4 B–D). However, there is the open challenge of effective extraction of structural information from imaging data as well as of identifying key parameter values necessary for mathematical modelling. Once validated, theoretical models could provide a bridge between in vivo and ex vivo or in vitro approaches to characterise placental structure and oxygenation in normal and pathological pregnancies (Lecarpentier et al. 2016).
Figure 4

Mathematical modelling of human placental perfusion and oxygenation at different scales

A, variability of perfusion in a fetoplacental vascular network (colour scale shows pressure for chorionic vessels and relative capillary flow for terminal capillaries, plotted as spheres) (Clark et al. 2015). B, distribution of a passive solute in the intervillous space of a single placental lobule (Chernyavsky et al. 2010). C, oxygen flux distribution over the capillary and syncytiotrophoblast surfaces of a single terminal villus (Pearce et al. 2016). D, microscopic flow in the intervillous space (Perazzolo et al. 2017). Images are reproduced with permission, subject to the respective copyrights.

Mathematical modelling of human placental perfusion and oxygenation at different scales

A, variability of perfusion in a fetoplacental vascular network (colour scale shows pressure for chorionic vessels and relative capillary flow for terminal capillaries, plotted as spheres) (Clark et al. 2015). B, distribution of a passive solute in the intervillous space of a single placental lobule (Chernyavsky et al. 2010). C, oxygen flux distribution over the capillary and syncytiotrophoblast surfaces of a single terminal villus (Pearce et al. 2016). D, microscopic flow in the intervillous space (Perazzolo et al. 2017). Images are reproduced with permission, subject to the respective copyrights.

Conclusion

The physiology of placental oxygen transfer is crucial for optimal fetal development and survival. Gross placental structure is well characterised and newer techniques, such as MRI, microCT and advanced microscopy scanning techniques, are affording greater detail. However, the function of the placenta remains poorly understood. Key measurements of oxygen and carbon dioxide levels in a normal human placenta remain elusive due to logistical and ethical complications with experimenting on in vivo human placentas, which are compounded by slow advances of ex vivo, in vitro and in silico work. This lack of fundamental understanding has led to slow progress in terms of treating pathological states such as in cases of fetal growth restriction. It is our theory that impaired placental oxygen transfer and metabolism (Schneider, 2015) may well be a key factor in many cases of FGR; however, whether this is due to abnormal structure or abnormal function is currently unknown. It is only with robust measures and consensus in experimental design that we can develop an integrated understanding of structure–function relationships within the placenta. This in turn will provide a basis for developing therapeutic interventions for the treatment of the placenta in fetal diseases in vivo.

Additional information

Competing interests

None declared.

Author contributions

All authors approved the final version of the manuscript and agree to be accountable for all aspects of the work. All persons designated as authors qualify for authorship, and all those who qualify for authorship are listed.

Funding

Funding was provided by the Medical Research Council, MR/N011538/1.
  64 in total

1.  Transport in the placenta: homogenizing haemodynamics in a disordered medium.

Authors:  Igor L Chernyavsky; Lopa Leach; Ian L Dryden; Oliver E Jensen
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-13       Impact factor: 4.226

2.  Effect of physiologic perfusion-fixation on the morphometrically evaluated dimensions of the term placental cotyledon.

Authors:  M Luckhardt; R Leiser; J Kingdom; A Malek; R Sager; C Kaisig; H Schneider
Journal:  J Soc Gynecol Investig       Date:  1996 Jul-Aug

3.  Measuring human placental blood flow with multidelay 3D GRASE pseudocontinuous arterial spin labeling at 3T.

Authors:  Xingfeng Shao; Dapeng Liu; Thomas Martin; Teresa Chanlaw; Sherin U Devaskar; Carla Janzen; Aisling M Murphy; Daniel Margolis; Kyunghyun Sung; Danny J J Wang
Journal:  J Magn Reson Imaging       Date:  2017-11-14       Impact factor: 4.813

4.  Oxygen, carbon dioxide, and hydrogen ion concentrations in arterial blood during pregnancy.

Authors:  J N Blechner; J R Cotter; V G Stenger; C M Hinkley; H Prystowsky
Journal:  Am J Obstet Gynecol       Date:  1968-01-01       Impact factor: 8.661

5.  Dual in vitro perfusion of an isolated lobe of human placenta: method and instrumentation.

Authors:  H Schneider; A Huch
Journal:  Contrib Gynecol Obstet       Date:  1985

6.  Cord blood oxygen saturation in vigorous infants at birth: what is normal?

Authors:  G M Arikan; H S Scholz; E Petru; M C Haeusler; J Haas; P A Weiss
Journal:  BJOG       Date:  2000-08       Impact factor: 6.531

7.  Blood gases, pH, and lactate in appropriate- and small-for-gestational-age fetuses.

Authors:  K H Nicolaides; D L Economides; P W Soothill
Journal:  Am J Obstet Gynecol       Date:  1989-10       Impact factor: 8.661

8.  Cord sampling for the evaluation of oxygenation and acid-base balance in growth-retarded human fetuses.

Authors:  G Pardi; M Buscaglia; E Ferrazzi; P Bozzetti; A M Marconi; I Cetin; F C Battaglia; E L Makowski
Journal:  Am J Obstet Gynecol       Date:  1987-11       Impact factor: 8.661

9.  [Relation between placental morphometry and fetal growth].

Authors:  K M Yu
Journal:  Zhonghua Fu Chan Ke Za Zhi       Date:  1992-07

10.  Hypoglycemia and the origin of hypoxia-induced reduction in human fetal growth.

Authors:  Stacy Zamudio; Tatiana Torricos; Ewa Fik; Maria Oyala; Lourdes Echalar; Janet Pullockaran; Emily Tutino; Brittney Martin; Sonia Belliappa; Elfride Balanza; Nicholas P Illsley
Journal:  PLoS One       Date:  2010-01-01       Impact factor: 3.240

View more
  15 in total

Review 1.  Tracking placental development in health and disease.

Authors:  John D Aplin; Jenny E Myers; Kate Timms; Melissa Westwood
Journal:  Nat Rev Endocrinol       Date:  2020-06-29       Impact factor: 43.330

2.  Challenges and controversies in perinatal physiology.

Authors:  L Bennet; T Ikeda; A J Llanos; J Nijhuis; A J Gunn
Journal:  J Physiol       Date:  2018-12       Impact factor: 5.182

Review 3.  Bioenergetic Evolution Explains Prevalence of Low Nephron Number at Birth: Risk Factor for CKD.

Authors:  Robert L Chevalier
Journal:  Kidney360       Date:  2020-07-07

4.  Non-invasive monitoring of blood oxygenation in human placentas via concurrent diffuse optical spectroscopy and ultrasound imaging.

Authors:  Lin Wang; Jeffrey M Cochran; Tiffany Ko; Wesley B Baker; Kenneth Abramson; Lian He; David R Busch; Venki Kavuri; Rebecca L Linn; Samuel Parry; Arjun G Yodh; Nadav Schwartz
Journal:  Nat Biomed Eng       Date:  2022-08-15       Impact factor: 29.234

5.  Quantitative longitudinal T2* mapping for assessing placental function and association with adverse pregnancy outcomes across gestation.

Authors:  Matthias C Schabel; Victoria H J Roberts; Karen J Gibbins; Monica Rincon; Jessica E Gaffney; Aaron D Streblow; Adam M Wright; Jamie O Lo; Byung Park; Christopher D Kroenke; Kathryn Szczotka; Nathan R Blue; Jessica M Page; Kathy Harvey; Michael W Varner; Robert M Silver; Antonio E Frias
Journal:  PLoS One       Date:  2022-07-19       Impact factor: 3.752

Review 6.  A systems perspective on placental amino acid transport.

Authors:  Jane K Cleal; Emma M Lofthouse; Bram G Sengers; Rohan M Lewis
Journal:  J Physiol       Date:  2018-09-07       Impact factor: 5.182

7.  Physical and geometric determinants of transport in fetoplacental microvascular networks.

Authors:  Alexander Erlich; Philip Pearce; Romina Plitman Mayo; Oliver E Jensen; Igor L Chernyavsky
Journal:  Sci Adv       Date:  2019-04-17       Impact factor: 14.136

8.  Quantifying the impact of tissue metabolism on solute transport in feto-placental microvascular networks.

Authors:  Alexander Erlich; Gareth A Nye; Paul Brownbill; Oliver E Jensen; Igor L Chernyavsky
Journal:  Interface Focus       Date:  2019-08-16       Impact factor: 3.906

Review 9.  Placental MRI and its application to fetal intervention.

Authors:  Rosalind Aughwane; Emma Ingram; Edward D Johnstone; Laurent J Salomon; Anna L David; Andrew Melbourne
Journal:  Prenat Diagn       Date:  2019-07-28       Impact factor: 3.050

10.  The haemodynamics of the human placenta in utero.

Authors:  Neele S Dellschaft; George Hutchinson; Simon Shah; Nia W Jones; Chris Bradley; Lopa Leach; Craig Platt; Richard Bowtell; Penny A Gowland
Journal:  PLoS Biol       Date:  2020-05-28       Impact factor: 8.029

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.