Literature DB >> 29376323

In Situ Monitoring of Pb2+ Leaching from the Galvanic Joint Surface in a Prepared Chlorinated Drinking Water.

Xiangmeng Ma1, Stephanie M Armas2, Mikhael Soliman3, Darren A Lytle4, Karin Chumbimuni-Torres2, Laurene Tetard3, Woo Hyoung Lee1.   

Abstract

A novel method using a micro-ion-selective electrode (micro-ISE) technique was developed for in situ lead monitoring at the water-metal interface of a brass-leaded solder galvanic joint in a prepared chlorinated drinking water environment. The developed lead micro-ISE (100 μm tip diameter) showed excellent performance toward soluble lead (Pb2+) with sensitivity of 22.2 ± 0.5 mV decade-1 and limit of detection (LOD) of 1.22 × 10-6 M (0.25 mg L-1). The response time was less than 10 s with a working pH range of 2.0-7.0. Using the lead micro-ISE, lead concentration microprofiles were measured from the bulk to the metal surface (within 50 μm) over time. Combined with two-dimensional (2D) pH mapping, this work clearly demonstrated that Pb2+ ions build-up across the lead anode surface was substantial, nonuniform, and dependent on local surface pH. A large pH gradient (ΔpH = 6.0) developed across the brass and leaded-tin solder joint coupon. Local pH decreases were observed above the leaded solder to a pH as low as 4.0, indicating it was anodic relative to the brass. The low pH above the leaded solder supported elevated lead levels where even small local pH differences of 0.6 units (ΔpH = 0.6) resulted in about four times higher surface lead concentrations (42.9 vs 11.6 mg L-1) and 5 times higher fluxes (18.5 × 10-6 vs 3.5 × 10-6 mg cm-2 s-1). Continuous surface lead leaching monitoring was also conducted for 16 h.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29376323      PMCID: PMC7321811          DOI: 10.1021/acs.est.7b05526

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  16 in total

1.  Corrosive microenvironments at lead solder surfaces arising from galvanic corrosion with copper pipe.

Authors:  Caroline K Nguyen; Kendall R Stone; Abhijeet Dudi; Marc A Edwards
Journal:  Environ Sci Technol       Date:  2010-09-15       Impact factor: 9.028

2.  Association between children's blood lead levels, lead service lines, and water disinfection, Washington, DC, 1998-2006.

Authors:  Mary Jean Brown; Jaime Raymond; David Homa; Chinaro Kennedy; Thomas Sinks
Journal:  Environ Res       Date:  2010-11-26       Impact factor: 6.498

Review 3.  Ion Selective Electrodes (ISEs) and interferences--a review.

Authors:  Goce Dimeski; Tony Badrick; Andrew St John
Journal:  Clin Chim Acta       Date:  2009-12-22       Impact factor: 3.786

4.  Nanomolar detection limits of Cd²⁺, Ag⁺, and K⁺ using paper-strip ion-selective electrodes.

Authors:  Samantha T Mensah; Yessenia Gonzalez; Percy Calvo-Marzal; Karin Y Chumbimuni-Torres
Journal:  Anal Chem       Date:  2014-07-22       Impact factor: 6.986

5.  Raman spectroscopy as a means for the identification of plattnerite (PbO2), of lead pigments and of their degradation products.

Authors:  L Burgio; R J Clark; S Firth
Journal:  Analyst       Date:  2001-02       Impact factor: 4.616

6.  Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS.

Authors:  A Ceresa; E Bakker; B Hattendorf; D Günther; E Pretsch
Journal:  Anal Chem       Date:  2001-01-15       Impact factor: 6.986

7.  Effect of free ammonia concentration on monochloramine penetration within a nitrifying biofilm and its effect on activity, viability, and recovery.

Authors:  Jonathan G Pressman; Woo Hyoung Lee; Paul L Bishop; David G Wahman
Journal:  Water Res       Date:  2011-12-07       Impact factor: 11.236

8.  In-situ 2D maps of pH shifts across brass-lead galvanic joints using microelectrodes.

Authors:  Xiangmeng Ma; Woo Hyoung Lee; Darren A Lytle
Journal:  Meas Sci Technol       Date:  2016-12-20       Impact factor: 2.046

9.  Low contribution of PbO2-coated lead service lines to water lead contamination at the tap.

Authors:  Simoni Triantafyllidou; Michael R Schock; Michael K DeSantis; Colin White
Journal:  Environ Sci Technol       Date:  2015-02-27       Impact factor: 9.028

10.  Subnanomolar Detection Limit Application of Ion-Selective Electrodes with Three-Dimensionally Ordered Macroporous (3DOM) Carbon Solid Contacts.

Authors:  Chun-Ze Lai; Marti M Joyer; Melissa A Fierke; Nicholas D Petkovich; Andreas Stein; Philippe Bühlmann
Journal:  J Solid State Electrochem       Date:  2009-01-01       Impact factor: 2.647

View more
  1 in total

1.  Theoretical equilibrium lead(II) solubility revisited: Open source code and practical relationships.

Authors:  David G Wahman; Matthew D Pinelli; Michael R Schock; Darren A Lytle
Journal:  AWWA Water Sci       Date:  2021-10-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.