Literature DB >> 29375711

An option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy for gastric cancer: A single-layer suturing technique for the stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures.

Takaya Tokuhara1, Eiji Nakata1, Toshiyuki Tenjo1, Isao Kawai1, Keisaku Kondo1, Hirofumi Ueda1, Atsushi Tomioka1.   

Abstract

We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility.

Entities:  

Keywords:  additional knotted suture; barbed suture; delta-shaped gastroduodenostomy; gastric cancer; totally laparoscopic distal gastrectomy

Year:  2017        PMID: 29375711      PMCID: PMC5766067          DOI: 10.3892/ol.2017.7306

Source DB:  PubMed          Journal:  Oncol Lett        ISSN: 1792-1074            Impact factor:   2.967


Introduction

Since laparoscopic-assisted distal gastrectomy was first reported by Kitano et al (1), the effectiveness for laparoscopic distal gastrectomy in the treatment of early gastric cancer has been established in several clinical studies (2–6). Moreover, in the past 15 years, totally laparoscopic distal gastrectomy (TLDG), in which all surgical procedures including lymph node dissection, gastric resection, and anastomosis are performed in a wide laparoscopic visual field, has been developed due to improvements in laparoscopic devices and techniques (7–18). Therefore, we introduced TLDG with Roux-en-Y reconstruction or Billroth-I (B-I) reconstruction in 2013. Antecolic Roux-en-Y reconstruction with antiperistaltic gastrojejunostomy was used when the remnant stomach was small or the first portion of the duodenum was short (8,11,16,17). On the other hand, B-I reconstruction was used when the tension in the gastroduodenostomy was low. Since intracorporeal delta-shaped B-I reconstruction, in which a functional end-to-end gastroduodenostomy was performed using endoscopic linear staplers, was first described by Kanaya et al, this technique has been accepted worldwide (7,9–15,17,18). However, the disadvantage of this procedure is the higher cost because it requires many linear stapler cartridges (7,9,10,12). Furthermore, Noshiro et al reported that one knotted suture was added on the greater curvature side of the closed entry hole for the stapler to prevent not only anastomotic leakage but also intraabdominal abscess around the anastomosis (15). V-Loc 180 Wound Closure device (Covidien, Mansfield, MA, USA) consists of a barbed unidirectional absorbable thread with a needle at one end and a loop at the other end. This design causes the tissues to adhere at many points without the need to tie surgical knots (19,20). Here, to reduce the number of linear stapler cartridges used in the intracorporeal delta-shaped gastroduodenostomy, we present a single-layer entire-thickness suturing technique for the stapler entry hole using 3-0 V-Loc 180 (VLOCL0604; taper point, 1/2 circle/26 mm; length, 15 cm). In addition, to prevent both anastomotic leakage and intraabdominal abscess around the anastomosis, we describe our initial experience combining the application of additional knotted sutures of 3-0 Prolene (Ethicon Endo-Surgery, Cincinnati, OH, USA).

Materials and methods

From June 2013 to February 2017, 20 patients underwent TLDG with delta-shaped gastroduodenostomy with the combined application of 3-0 V-Loc 180 of 15 cm in length and 3-0 Prolene at Otori Stomach and Intestines Hospital. The indication for TLDG at our institution is T1N0M0 gastric cancer, according to the Japanese classification of gastric carcinoma (21), that is located in the middle or lower third of the stomach and is not a candidate for endoscopic submucosal dissection. B-I reconstruction was performed when the tension in the gastroduodenostomy was low. Patients were placed in the modified lithotomy position. The operator stood between the patient's legs, with the first assistant operating the laparoscope on the left side and the second assistant on the right side. After five trocars were placed in the upper abdomen including the umbilicus and a Nathanson's retractor was inserted from just below the xiphoid process to elevate the round ligament and the lateral segment of the liver, lymphadenectomy based on the Japanese treatment guidelines was performed under a pneumoperitoneum (22). The duodenal bulb was transected in a posteroanterior direction using one endoscopic linear stapler during lymphadenectomy. Proximal gastric resection with reference to preoperative endoscopic marking was carried out (23), and the specimen was removed through the extended umbilical wound using a large plastic bag. Pneumoperitoneum was re-established before the reconstruction. A small hole was made on the greater curvature side of the remnant stomach and the posterior side of the duodenum. A 45-mm linear stapler was introduced through a left lower port, with one jaw in each hole. The stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After confirming that there was no bleeding in the intraluminal anastomotic line, the entry hole for the stapler was closed by the single-layer entire-thickness suturing technique using a knotless barbed suture combined with the application of additional knotted sutures. An entire-thickness suture with 3-0 Prolene was placed on the lesser curvature side of the entry hole using the extracorporeal slip knot technique (Roeder's knot) (Fig. 1). After creating a good view of the greater curvature side by retracting this knotted suture toward the ventral side (Fig. 2), continuous suturing with a 15-cm 3-0 V-Loc 180 device was carried out from the greater curvature side to the lesser curvature side. The first entire-thickness stitch was positively placed on the greater curvature side, and the needle was passed through the loop (Fig. 3). The second and third stitches were made between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum, with the duodenal mucosa being sutured as minutely as possible (Figs. 4 and 5) to avoid extroversion of the mucosa of the alimentary tract near the greater curvature side (Fig. 6). Thereafter, single-layer entire-thickness continuous suturing was performed until the suture crossed over the knotted suture on the lesser curvature side (Fig. 7). The suture end was then cut simply, as short as possible, without the need for a knot. Routinely, one or two entire-thickness knotted sutures with 3-0 Prolene were added at the site near the greater curvature side to reinforce this site and avoid loosening of the 3-0 V-Loc 180 (Fig. 8). Similar additional sutures were made on the site with a broad pitch. The intracorporeal B-I reconstruction was then accomplished (Fig. 9).
Figure 1.

An entire-thickness suture of 3-0 Prolene is made on the lesser curvature side of the stapler entry hole using the extracorporeal slip knot technique (Roeder's knot).

Figure 2.

The knotted suture at the lesser curvature side (white arrow) is retracted toward the ventral side to create a good view of the greater curvature side of the stapler entry hole (red arrow).

Figure 3.

The first entire-thickness stitch with 3-0 V-loc 180 is placed on the greater curvature side of the stapler entry hole and the needle is passed through the loop.

Figure 4.

The second and third stitches with 3-0 V-Loc 180 are made on the seromuscular layer of the remnant stomach.

Figure 5.

The second and third stitches with 3-0 V-Loc 180 are made on the entire-thickness layer of the duodenum, with the duodenal mucosa being sutured as minutely as possible.

Figure 6.

There is no extroversion of mucosa of the alimentary tract near the greater curvature side of the stapler entry hole.

Figure 7.

The single-layer entire-thickness continuous suture of the entry hole with 3-0 V-Loc 180 is performed until it crosses over the knotted 3-0 Prolene suture on the lesser curvature side.

Figure 8.

One or two entire-thickness knotted 3-0 Prolene sutures are routinely added at the site near the greater curvature side of the stapler entry hole.

Figure 9.

Intracorporeal Billroth-I reconstruction is completed.

Results

Patient characteristics and operative outcomes are shown in Table I. In all patients (13 men and 7 women), TLDG with this reconstruction technique was successfully performed without any intraoperative complications. The mean patient age was 64.4±7.8 years (45–77 years), and the mean body mass index was 21.6±1.8 kg/m2 (19.3–24.6 kg/m2). The mean operation time was 249±23 min (205–273 min), and the mean estimated blood loss was 22.5±4.6 ml (20–30 ml). The mean number of linear stapler cartridges used intraoperatively was 4.4±0.5 (4–5). The overall mean suturing time of the stapler entry hole was 14.8±1.6 min (12.0–18.1 min). The mean suturing time involving the 3-0 V-Loc 180 was 9.4±1.6 min (7.4–13.0 min), and the mean number of additional knotted sutures placed was 2.9±0.9 (2–4). According to the postoperative complications related to the anastomosis, neither anastomotic leakage nor intraabdominal abscess around the anastomosis, were encountered. However, in one patient, anastomotic hemorrhage at the vertex of the V-shaped staple line requiring endoscopic hemostasis occurred on postoperative day 1, which was categorized as grade IIIa according to the Clavien-Dindo classification (24). There were no other complications, including anastomotic stenosis, pancreatic fistula, and intestinal obstruction. The mean postoperative hospital stay was 13.8±1.5 days (12–17 days). Fig. 10 is a typical upper gastrointestinal fluoroscopic image on postoperative day 3 that shows no anastomotic leakage and stenosis.
Table I.

Patient characteristics and outcomes.

Characteristics and outcomesData
Cases, n20
Age, years64.4±7.8
Sex, n
  Male13
  Female7
BMI, kg/m221.6±1.8
Operative time, min249±23
Blood loss, ml22.5±4.6
Linear stapler cartridges used, n4.4±0.5
Overall suturing time, min14.8±1.6
V-Loc suturing time, min9.4±1.6
Additional knotted sutures, n2.9±0.9
Postoperative hospital stay, d13.8±1.5
Postoperative complications, n
  Anastomotic leakage0
  Intraabdominal abscess0
  Anastomotic hemorrhage1
  Anastomotic stenosis0
  Pancreatic fistula0
  Intestinal obstruction0

Data are presented as the mean ± SD. BMI, Body Mass Index.

Figure 10.

Postoperative fluorography demonstrates the smooth passage of oral contrast through the anastomosis without leakage or stenosis.

Discussion

To securely perform TLDG for gastric cancer, establishment of safe and reproducible intracorporeal reconstruction is essential in addition to precise lymph node dissection and accurate proximal gastric resection. In B-I reconstruction for TLDG, the delta-shaped gastroduodenostomy using only endoscopic linear staplers has been accepted worldwide due to its safety and simplicity (7,9–15,17,18), but the disadvantage of this technique is its higher cost (7,9,10,12). On the other hand, some authors have reported the efficacy of the knotless barbed unidirectional absorbable suture in gastrointestinal reconstruction (25–29), and especially, Nemecek et al stated that single-layer entire-thickness sutures of the alimentary tract with 3-0 V-Loc 180 had higher bursting pressures than those with 3-0 monofilament in a cadaver study (27). Therefore, to reduce the number of linear stapler cartridges used in the delta-shaped gastroduodenostomy, a single-layer entire-thickness continuous suturing technique for the stapler entry hole using a 15-cm-long 3-0 V-Loc 180 device was applied because it was not only effective for gastrointestinal reconstruction but also easy to handle in the abdominal cavity. In this patient series, no linear stapler cartridges were used to close the entry hole. Noshiro et al reported that among the initial 71 patients undergoing delta-shaped gastroduodenostomy using linear staplers, 6 experienced anastomotic leakage and 2 developed intraabdominal abscess around the anastomosis, and in all of these patients, the affected site was the greater curvature side of the closed entry hole for the stapler (15). They indicated two possible reasons for these complications. First, the procedure for closing the greater curvature side of the entry hole was uncertain because this site tended to roll backward behind the linear stapler. Next, the extroverted gastroduodenostomy sometimes directly contacted the pancreatic head after infrapyloric lymph node dissection, and so even minimal leakage of pancreatic juice might be activated by the attachment of mucosa of the alimentary tract. They added one knotted suture on the greater curvature side of the closed entry hole in the last 71 patients and neither anastomotic leakage nor intraabdominal abscess around the anastomosis occurred among these patients. Thus, to stabilize the outcomes of the delta-shaped gastroduodenostomy with 3-0 V-Loc 180, we standardized the procedure by adding knotted 3-0 Prolene sutures using the extracorporeal slip knot technique (Roeder's knot). The steps of this procedure include; i) retracting the knotted 3-0 Prolene suture on the lesser curvature side toward the ventral side to create a good view of the greater curvature side of the entry hole for the stapler; ii) performing single-layer entire-thickness continuous suturing of the entry hole using 3-0 V-Loc 180 from the greater curvature side to the lesser curvature side; iii) placing the second and third stitches of 3-0 V-Loc 180 between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum by suturing the duodenal mucosa as minutely as possible to avoid extroversion of mucosa of the alimentary tract near the greater curvature side; iv) routinely adding one or two entire-thickness knotted sutures with 3-0 Prolene at the site near the greater curvature side to reinforce this site and avoid loosening of the 3-0 V-Loc 180; and v) placing similar additional knotted sutures on the site with a broad pitch. In this patient series, this reconstruction procedure resulted in no incidences of anastomotic leakage or intraabdominal abscess around the anastomosis. These results were comparable to those of the last 71 patients reported by Noshiro et al. The knotless barbed suture is assumed to make intracorporeal digestive anastomoses easier to perform because it does not require any knots and the tension is self-maintained during the running suture, with no need for continuous traction (28). In addition, the extracorporeal knotted suturing technique such as Roeder's knot could be carried out more easily than the intracorporeal ligation technique. Therefore, it is considered that a single-layer suturing technique for the stapler entry hole using 3-0 V-Loc 180 combined with the application of additional knotted sutures of 3-0 Prolene is not difficult to master for the gastrointestinal surgeons. Although there is a concern that the free tail of the barbed suture might cause intestinal obstruction (30–32), this complication was not encountered in this series. For this reason, it could be considered that we cut the suture end as short as possible and the free tail located at the lesser curvature side of the closed entry hole was covered by the liver. In conclusion, it is suggested that a single-layer entire-thickness suturing technique for the stapler entry hole using 3-0 V-Loc 180 with a length of 15 cm combined with the application of additional knotted sutures of 3-0 Prolene can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility. Examination of a larger number of patients needs to be performed to draw a conclusion on the utility of this reconstruction technique.
  32 in total

1.  Intestinal obstruction following use of laparoscopic barbed suture: a new complication with new material?

Authors:  Nicolas C Buchs; Sandrine Ostermann; Johannes Hauser; Bruno Roche; Christophe E Iselin; Philippe Morel
Journal:  Minim Invasive Ther Allied Technol       Date:  2011-12-07       Impact factor: 2.442

2.  A totally laparoscopic distal gastrectomy with gastroduodenostomy (TLDG) for improvement of the early surgical outcomes in high BMI patients.

Authors:  Min Gyu Kim; Hironori Kawada; Beom Su Kim; Tae Hwan Kim; Kap Choong Kim; Jeong Hwan Yook; Byung Sik Kim
Journal:  Surg Endosc       Date:  2010-09-11       Impact factor: 4.584

3.  An additional suture secures against pitfalls in delta-shaped gastroduodenostomy after laparoscopic distal gastrectomy.

Authors:  Hirokazu Noshiro; Hironori Iwasaki; Yoshihiro Miyasaka; Kiichirou Kobayashi; Toshihiro Masatsugu; Michiaki Akashi; Osamu Ikeda
Journal:  Gastric Cancer       Date:  2011-08-18       Impact factor: 7.370

4.  Japanese classification of gastric carcinoma: 3rd English edition.

Authors: 
Journal:  Gastric Cancer       Date:  2011-06       Impact factor: 7.370

5.  Unidirectional barbed suture versus continuous suture with intracorporeal knots in laparoscopic myomectomy: a randomized study.

Authors:  Franco Alessandri; Valentino Remorgida; Pier Luigi Venturini; Simone Ferrero
Journal:  J Minim Invasive Gynecol       Date:  2010-07-31       Impact factor: 4.137

6.  A randomized controlled trial comparing open vs laparoscopy-assisted distal gastrectomy for the treatment of early gastric cancer: an interim report.

Authors:  Seigo Kitano; Norio Shiraishi; Kyuzo Fujii; Kazuhiro Yasuda; Masafumi Inomata; Yosuke Adachi
Journal:  Surgery       Date:  2002-01       Impact factor: 3.982

7.  Prospective randomized study of open versus laparoscopy-assisted distal gastrectomy with extraperigastric lymph node dissection for early gastric cancer.

Authors:  H Hayashi; T Ochiai; H Shimada; Y Gunji
Journal:  Surg Endosc       Date:  2005-07-28       Impact factor: 4.584

8.  Laparoscopy-assisted and open distal gastrectomies for early gastric cancer at a general hospital in Japan.

Authors:  Takuji Naka; Takanori Ishikura; Syunsuke Shibata; Yumi Yamaguchi; Minoru Ishiguro; Eiichi Yurugi; Hideaki Nishidoi; Hirofumi Kudoh; Satoshi Murakami; Shunichi Tsujitani
Journal:  Hepatogastroenterology       Date:  2005 Jan-Feb

9.  Advantages of totally laparoscopic distal gastrectomy over laparoscopically assisted distal gastrectomy for gastric cancer.

Authors:  Osamu Ikeda; Yoshihisa Sakaguchi; Yoshiro Aoki; Norifumi Harimoto; Jyunya Taomoto; Takaaki Masuda; Takefumi Ohga; Eisuke Adachi; Yasushi Toh; Takeshi Okamura; Hideo Baba
Journal:  Surg Endosc       Date:  2009-03-05       Impact factor: 4.584

10.  Japanese gastric cancer treatment guidelines 2014 (ver. 4).

Authors: 
Journal:  Gastric Cancer       Date:  2016-06-24       Impact factor: 7.370

View more
  4 in total

1.  Billroth-I reconstruction using an overlap method in totally laparoscopic distal gastrectomy: propensity score matched cohort study of short- and long-term outcomes compared with Roux-en-Y reconstruction.

Authors:  Yusuke Watanabe; Masato Watanabe; Nobuhiro Suehara; Michiyo Saimura; Yusuke Mizuuchi; Kazuyoshi Nishihara; Toshimitsu Iwashita; Toru Nakano
Journal:  Surg Endosc       Date:  2019-02-13       Impact factor: 4.584

2.  The DOLFIN method: a novel laparoscopic Billroth-I gastroduodenostomy for gastric cancer with duodenal invasion.

Authors:  Naoki Shinno; Takeshi Omori; Hisashi Hara; Masaaki Yamamoto; Kohei Fujita; Takashi Kanemura; Tomohira Takeoka; Takahito Sugase; Masayoshi Yasui; Chu Matsuda; Hiroshi Wada; Junichi Nishimura; Naotsugu Haraguchi; Hirofumi Akita; Shinichiro Hasegawa; Nozomu Nakai; Kei Asukai; Yousuke Mukai; Hiroshi Miyata; Masayuki Ohue; Masato Sakon
Journal:  Langenbecks Arch Surg       Date:  2022-09-14       Impact factor: 2.895

3.  Application of Overlap Gastroduodenostomy in Billroth I Anastomosis after Totally Laparoscopic Distal Gastrectomy for Gastric Cancer.

Authors:  Guojun Chen; Wenhuan Li; Weihua Yu; Dong Cen; Xianfa Wang; Peng Luo; Jiafei Yan; Guofu Chen; Yiping Zhu; Linhua Zhu
Journal:  Can J Gastroenterol Hepatol       Date:  2022-08-12

4.  Modified delta-shaped gastroduodenostomy consisting of linear stapling and single-layer suturing with the operator positioned between the patient's legs: A technique preventing intraoperative duodenal injury and postoperative anastomotic stenosis.

Authors:  Takaya Tokuhara; Eiji Nakata; Toshiyuki Tenjo; Isao Kawai; Keisaku Kondo; Shigeru Hatabe
Journal:  PLoS One       Date:  2020-03-06       Impact factor: 3.240

  4 in total