Biotolerant and haemodynamic effects of copolymerization with acrylic acid on Dacron arterial prostheses.

R M Miller, D E Taylor, B S Ringrose.   

Abstract

The biotolerant and haemodynamic effects of three types of woven polyethylene terephthalate (Dacron) arterial prostheses were compared. Two of these were unmodified, one low, one high porosity; and the third was the latter type radiation graft copolymerized with 5% acrylic acid. The prostheses were implanted as aorto-aortic bypass grafts, in dogs, for periods ranging from three to seventeen months. The copolymerized prosthesis exhibited the smallest rise in circumferential elastance from the 'as supplied' state, as well as a significantly slower pulse wave velocity, a significantly thinner internal lining, and a markedly lower longitudinal impedance. Of the unmodified prostheses, the low porosity graft had a significantly greater circumferential elastance, the poorest handling characteristics, and a tendency for pseudo intimal detachment. It was concluded that, although there was little difference between the two unmodified prostheses, the low porosity one had little to recommend it for use in small calibre bypass grafting. Copolymerization with acrylic acid produced better haemotolerant and haemodynamic results as well as surface properties which appeared to discourage fibrin and platelet adherence, and promote a more complete and organised pseudointima.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2937362      PMCID: PMC2497801     

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  6 in total

1.  Porosity: primary determinant of ultimate fate of synthetic vascular grafts.

Authors:  S A WESOLOWSKI; C C FRIES; K E KARLSON; M DE BAKEY; P N SAWYER
Journal:  Surgery       Date:  1961-07       Impact factor: 3.982

2.  Preclinical evaluation of knitted radiation graft copolymer elastomeric vascular prostheses.

Authors:  J S Whamond; D E Taylor; P Fydelor; B S Ringrose
Journal:  Life Support Syst       Date:  1983

3.  Stress-strain characteristics of various arterial grafts.

Authors:  D E Hokanson; D E Strandness
Journal:  Surg Gynecol Obstet       Date:  1968-07

4.  Pulsatile blood-flow in arterial grafts.

Authors:  R N Baird; W M Abbott
Journal:  Lancet       Date:  1976-10-30       Impact factor: 79.321

5.  Effects of intramural thrombus on haemodynamic performance of 5-6 mm.id vascular prostheses.

Authors:  E J Santiago; R M Miller; D E Taylor
Journal:  Life Support Syst       Date:  1983

6.  Evaluation of a new vascular prosthesis with optimal specifications.

Authors:  S A Wesolowski; C C Fries; J D McMahon; A Martinez
Journal:  Surgery       Date:  1966-01       Impact factor: 3.982