Wear of polyetherketoneketones - Influence of titanium dioxide content and antagonistic material.

Thomas Kewekordes1, Sebastian Wille2, Matthias Kern3.   

Abstract

OBJECTIVE: The aim of this laboratory study was to analyze the influence of titanium dioxide (TiO2) content and antagonistic material on the wear of polyetherketoneketones (PEKKs).
METHODS: Twenty-four disk-shaped specimens of two PEKK materials containing either 10wt% or 20wt% TiO2 particles (P10 and P20) were dynamically loaded in a chewing simulator with 49N and additional thermal cycling (5-55°C). Subgroups of 8 specimens each were loaded with spherical antagonists made from either steatite ceramic (St), zirconia (Zr), or the same PEKK material (P10 or P20). After 120,000, 240,000, 480,000, 840,000, and 1,200,000 loading cycles the vertical substance loss and the volume loss of the loaded specimens were evaluated using a laser scanner. Data were checked considering the normal distribution (Shapiro-Wilk test) and were inspected for significant differences by means of single factor variance analyses and post hoc pair comparison (Games-Howell test).
RESULTS: After 1,200,000 chewing cycles, statistical analyses revealed a significant influence of the antagonistic material. A significant difference was also found between the tested PEKKs if Zr was used as the antagonist. The volume loss ranged from between 0.073mm3 (P20-P20) and 0.228mm3 (P10-St), and the vertical substance loss ranged between 73.71μm (P20-P20) and 115.268μm (P10-Zr). SIGNIFICANCE: The inclusion of TiO2 particles influences the wear behavior of PEKK materials.
Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chewing simulator; Laser scanning microscope; PEKK; Thermal cycling; TiO(2); Wear

Mesh:

Substances:

Year:  2018        PMID: 29373134     DOI: 10.1016/j.dental.2017.12.009

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  Evaluation of the effects of different surface modification methods on the bond strength of high-performance polymers and resin matrix ceramics.

Authors:  Büşra Tosun; Nuran Yanıkoğlu
Journal:  Clin Oral Investig       Date:  2022-01-24       Impact factor: 3.573

Review 2.  Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses.

Authors:  Hatim Alqurashi; Zohaib Khurshid; Azeem Ul Yaqin Syed; Syed Rashid Habib; Dinesh Rokaya; Muhammad Sohail Zafar
Journal:  J Adv Res       Date:  2020-09-18       Impact factor: 10.479

Review 3.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.