The degradation and transport mechanism of a Mg-Nd-Zn-Zr stent in rabbit common carotid artery: A 20-month study.

Jian Zhang1, Haiyan Li2, Wu Wang3, Hua Huang4, Jia Pei4, Haiyun Qu5, Guangyin Yuan6, Yongdong Li7.   

Abstract

Mg-based stent is a promising candidate of the next generation fully degradable vascular stents. The latest progress includes the CE approval of the Magmaris ® WE43 based drug eluting stent. However, so far, the long term (more than 1 year implantation) in vivo degradation and the physiological effects caused by the degradation products were still unclear. In this study, a 20 month observation was carried out after the bare Mg-Nd-Zn-Zr (abbr. JDBM) stent prototype was implanted into the common carotid artery of New Zealand white rabbit in order to evaluate its safety, efficacy and especially degradation behavior. The degradation of the main second phase Mg12Nd was also studied. Results showed that the bare JDBM stent had good safety and efficacy with a complete re-endothelialization within 28 days. The JDBM stent struts were mostly replaced in situ by degradation products in 4 month. The important finding was that the volume and Ca concentration of the degradation products decreased in the long term, eliminating the clinicians' concern of possible vessel calcification. In addition, the alloying elements Mg and Zn in the stent could be safely metabolized as continuous enrichment in any of the main organs were not detected although Nd and Zr showed an abrupt increase in spleen and liver after 1 month implantation. Collectively, the long term in vivo results showed the rapid re-endothelialization of JDBM stent and the long term safety of the degradation products, indicating its great potential as the backbone of the fully degradable vascular stent. STATEMENT OF SIGNIFICANCE: Mg-based stent is a promising candidate of the next generation fully degradable stents, especially after the recent market launch of one of its kind (Magmaris). However the fundamental question about the long term degradation and metabolic mechanism of Mg-based stent and its degradation products remain unanswered. We implanted our patented Mg-Nd-Zn-Zr bare stent into the common carotid artery of rabbits and conducted a 20 months observation. We found that the Ca containing degradation products could be further degraded in vivo. All the alloying elements showed no continuous enrichment in the main organs of rabbits. These findings eliminate the clinicians' concern of possible vessel calcification and element enrichment after the implantation of Mg alloy based stents to some extent.
Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Common carotid artery; In vivo degradation; Mg alloy stent; Transport mechanism; Vessel calcification

Mesh:

Substances:

Year:  2018        PMID: 29369807     DOI: 10.1016/j.actbio.2018.01.018

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  15 in total

1.  In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy.

Authors:  Chenxin Chen; Jiahui Chen; Wei Wu; Yongjuan Shi; Liang Jin; Lorenza Petrini; Li Shen; Guangyin Yuan; Wenjiang Ding; Junbo Ge; Elazer R Edelman; Francesco Migliavacca
Journal:  Biomaterials       Date:  2019-08-05       Impact factor: 12.479

Review 2.  A review of current challenges and prospects of magnesium and its alloy for bone implant applications.

Authors:  Meysam Nasr Azadani; Abolfazl Zahedi; Oluwole Kingsley Bowoto; Bankole Ibrahim Oladapo
Journal:  Prog Biomater       Date:  2022-03-03

Review 3.  Current status and outlook of potential applications of biodegradable materials in cerebral vascular stents.

Authors:  Yiqi Xing; Guobiao Liang; Tingzhun Zhu
Journal:  Neurosurg Rev       Date:  2022-10-10       Impact factor: 2.800

Review 4.  Magnesium-based materials in orthopaedics: material properties and animal models.

Authors:  Xirui Jing; Qiuyue Ding; Qinxue Wu; Weijie Su; Keda Yu; Yanlin Su; Bing Ye; Qing Gao; Tingfang Sun; Xiaodong Guo
Journal:  Biomater Transl       Date:  2021-09-28

5.  Designing Better Cardiovascular Stent Materials - A Learning Curve.

Authors:  Irsalan Cockerill; Carmine Wang See; Marcus L Young; Yadong Wang; Donghui Zhu
Journal:  Adv Funct Mater       Date:  2020-11-04       Impact factor: 18.808

6.  Microbial ingress and in vitro degradation enhanced by glucose on bioabsorbable Mg-Li-Ca alloy.

Authors:  Ling-Yu Li; Zhuang-Zhuang Han; Rong-Chang Zeng; Wei-Chen Qi; Xiao-Fan Zhai; Yi Yang; Yun-Tian Lou; Tingyue Gu; Dake Xu; Ji-Zhou Duan
Journal:  Bioact Mater       Date:  2020-06-30

7.  The Effect of Zn Content on the Mechanical Properties of Mg-4Nd-xZn Alloys (x = 0, 3, 5 and 8 wt.%).

Authors:  Serge Gavras; Ricardo H Buzolin; Tungky Subroto; Andreas Stark; Domonkos Tolnai
Journal:  Materials (Basel)       Date:  2018-06-28       Impact factor: 3.623

8.  Phase Formation during Solidification of Mg-Nd-Zn Alloys: An In Situ Synchrotron Radiation Diffraction Study.

Authors:  Domonkos Tolnai; Tungky Subroto; Serge Gavras; Ricardo Buzolin; Andreas Stark; Norbert Schell; Norbert Hort
Journal:  Materials (Basel)       Date:  2018-09-06       Impact factor: 3.623

9.  Comparison of endothelial cell attachment on surfaces of biodegradable polymer-coated magnesium alloys in a microfluidic environment.

Authors:  Lumei Liu; Sang-Ho Ye; Xinzhu Gu; Teal Russell; Zhigang Xu; Jagannathan Sankar; William R Wagner; Young-Choon Lee; Yeoheung Yun
Journal:  PLoS One       Date:  2018-10-10       Impact factor: 3.240

10.  Translational status of biomedical Mg devices in China.

Authors:  Yu Sun; Hongliu Wu; Wenhui Wang; Rui Zan; Hongzhou Peng; Shaoxiang Zhang; Xiaonong Zhang
Journal:  Bioact Mater       Date:  2019-11-15
View more