Literature DB >> 29359391

Angiographic follow-up of infants and children undergoing percutaneous carotid artery interventions.

R Allen Ligon1, Dennis W Kim1, Robert N Vincent1, Holly D Bauser-Heaton1, Yinn K Ooi1, Christopher J Petit1.   

Abstract

OBJECTIVE: The purpose of this study was to review the outcomes following the percutaneous carotid arterial (PCA) approach in infants and children with congenital heart disease.
BACKGROUND: PCA access is becoming more commonly adopted following reports demonstrating it is a safe alternative to surgical carotid cutdown and even the femoral arterial route. However, follow-up outcomes after PCA remain unreported.
METHODS: We reviewed all cases with PCA access and follow-up catheterizations which included carotid artery (CA) angiography between May 2012 until December 2016. We examined for evidence of CA stenosis at follow-up angiography and assessed any other CA complications associated with vascular access.
RESULTS: There were 61 PCA catheterizations performed in 55 unique patients. Follow-up CA imaging with angiography was available in 43 patients (78%, 43/55). There was no vessel stenosis nor lumen irregularity in 28 (65%) patients. In 15 cases (35%), there was a mild degree of irregularity or narrowing by angiography (median 4.1%, range 2.3%-12.5%). Nine patients underwent repeat PCA catheterizations. Seven of these had no visible vascular stenosis on follow-up angiographic imaging, including a patient who was accessed three separate times from the CA. No statistically significant risk factors for developing mild CA stenosis were identified.
CONCLUSIONS: PCA access for pediatric interventional catheterization appears to be safe with a very low rate of mild stenosis, and very few complications. Follow-up outcomes in our series are excellent, with a CA patency rate of 100%, even after multiple procedures. Mild CA stenosis was not associated with patient size or sheath introducer caliber. While the acute results from percutaneous CA catheterization have proven safe in recent literature, longer-term outcomes remain unreported. At our institution, the outcomes following percutaneous carotid access are associated with an excellent patency rate of 100%, even after multiple procedures on the same vessel. A low incidence of mild vessel stenosis can be appreciated on follow-up angiography.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  cardiac catheterization; pediatric cardiology

Mesh:

Year:  2018        PMID: 29359391     DOI: 10.1002/ccd.27481

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  Patient-Specific 3-Dimensional-Bioprinted Model for In Vitro Analysis and Treatment Planning of Pulmonary Artery Atresia in Tetralogy of Fallot and Major Aortopulmonary Collateral Arteries.

Authors:  Martin L Tomov; Alexander Cetnar; Katherine Do; Holly Bauser-Heaton; Vahid Serpooshan
Journal:  J Am Heart Assoc       Date:  2019-12-10       Impact factor: 5.501

2.  Direct percutaneous transcarotid approach for embolization of dural sinus malformation in a premature neonate: A case report.

Authors:  Yasaman Moazeni; Ramez N Abdalla; Donald R Cantrell; Michael C Hurley; Sameer A Ansari; Arthur J DiPatri; Ali Shaibani
Journal:  Interv Neuroradiol       Date:  2021-03-21       Impact factor: 1.764

3.  A 3D Bioprinted In Vitro Model of Pulmonary Artery Atresia to Evaluate Endothelial Cell Response to Microenvironment.

Authors:  Martin L Tomov; Lilanni Perez; Liqun Ning; Huang Chen; Bowen Jing; Andrew Mingee; Sahar Ibrahim; Andrea S Theus; Gabriella Kabboul; Katherine Do; Sai Raviteja Bhamidipati; Jordan Fischbach; Kevin McCoy; Byron A Zambrano; Jianyi Zhang; Reza Avazmohammadi; Athanasios Mantalaris; Brooks D Lindsey; David Frakes; Lakshmi Prasad Dasi; Vahid Serpooshan; Holly Bauser-Heaton
Journal:  Adv Healthc Mater       Date:  2021-08-08       Impact factor: 11.092

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.