Literature DB >> 29356171

The impact of closed-loop electronic medication management on time to first dose: a comparative study between paper and digital hospital environments.

Jodie A Austin1, Ian R Smith2, Amina Tariq3.   

Abstract

Closed-loop electronic medication management systems (EMMS) are recognised as an effective intervention to improve medication safety, yet evidence of their effectiveness in hospitals is limited. Few studies have compared medication turnaround time for a closed-loop electronic versus paper-based medication management environment.
OBJECTIVE: To compare medication turnaround times in a paper-based hospital environment with a digital hospital equipped with a closed-loop EMMS, consisting of computerised physician order entry, profiled automated dispensing cabinets packaged with unit dose medications and barcode medication administration.
METHOD: Data were collected during 2 weeks at three private hospital sites (one with closed-loop EMMS) within the same organisation network in Queensland, Australia. Time between scheduled and actual administration times was analysed for first dose of time-critical and non-critical medications located on the ward or sourced via pharmacy. KEY
FINDINGS: Medication turnaround times at the EMMS site were less compared to the paper-based sites (median, IQR: 35 min, 8-57 min versus 120 min, 30-180 min, P < 0.001). For time-critical medications, 77% were administered within 60 min of scheduled time at the EMMS site versus 38% for the paper-based sites. Similar difference was observed for non-critical medications, 80% were administered within 60 min of their scheduled time at the EMMS site versus 41% at the paper-based facilities.
CONCLUSION: The study indicates medication turnaround times utilising a closed-loop EMMS are less compared to paper-based systems. This improvement may be attributable to increased accessibility of medications using automated dispensing cabinets and electronic medication administration records flagging tasks to nurses in real time.
© 2018 Royal Pharmaceutical Society.

Keywords:  closed-loop; electronic; medication; turnaround time

Mesh:

Year:  2018        PMID: 29356171     DOI: 10.1111/ijpp.12432

Source DB:  PubMed          Journal:  Int J Pharm Pract        ISSN: 0961-7671


  5 in total

1.  Implementing a New Electronic Health Record System in a University Hospital: The Effect on Reported Medication Errors.

Authors:  Carita Lindén-Lahti; Sanna-Maria Kivivuori; Lasse Lehtonen; Lotta Schepel
Journal:  Healthcare (Basel)       Date:  2022-05-31

2.  Identification and safe storage of look-alike, sound-alike medicines in automated dispensing cabinets.

Authors:  Henna Karoliina Ruutiainen; Miia Marjukka Kallio; Sini Karoliina Kuitunen
Journal:  Eur J Hosp Pharm       Date:  2021-01-15

3.  Nurses´ perceptions of automated dispensing cabinets - an observational study and an online survey.

Authors:  Riikka Metsämuuronen; Hannu Kokki; Toivo Naaranlahti; Minna Kurttila; Reeta Heikkilä
Journal:  BMC Nurs       Date:  2020-04-19

4.  Systemic Defenses to Prevent Intravenous Medication Errors in Hospitals: A Systematic Review.

Authors:  Sini Karoliina Kuitunen; Ilona Niittynen; Marja Airaksinen; Anna-Riia Holmström
Journal:  J Patient Saf       Date:  2021-12-01       Impact factor: 2.243

5.  Describing voluntarily reported fluid therapy incidents in the care of critically ill patients: Identifying, and learning from, points of risk at the national level.

Authors:  Minna Kurttila; Susanna Saano; Raisa Laaksonen
Journal:  Explor Res Clin Soc Pharm       Date:  2021-04-18
  5 in total