Literature DB >> 2934968

Echocardiographic evaluation of left ventricular function during coronary artery angioplasty.

M Alam, F Khaja, J Brymer, M Marzelli, S Goldstein.   

Abstract

Balloon occlusion of a stenotic coronary artery during percutaneous coronary artery angioplasty provides a unique opportunity to study the effect of acute myocardial ischemia on left ventricular (LV) function. Simultaneous M-mode and 2-dimensional (2-D) echocardiograms and a 6-lead electrocardiogram were recorded during 20 episodes of coronary artery occlusion and release in 12 patients. No patient had previous myocardial infarction and all had normal LV function by angiography. All patients had isolated single coronary artery disease, with left anterior descending stenosis in 8 and right coronary stenosis in 4. In 18 of 20 episodes (90%), M-mode echocardiography during balloon occlusion revealed a significant (p less than 0.001) decrease in LV systolic, diastolic and percent systolic wall thickness; systolic excursion; systolic and diastolic endocardial velocities; and fractional shortening. These changes were observed in the area of the ventricular septum in patients with left anterior descending occlusion and posteroinferior wall in those with right coronary artery occlusion. Two-dimensional echocardiography revealed varying degrees of hypokinesia, akinesia and dyskinesia during balloon occlusion in 18 instances. The echocardiographic changes were observed within 15 to 20 seconds of balloon occlusion and resolved 10 to 20 seconds after balloon deflation. All patients who had echocardiographic changes during balloon occlusion also had concomitant electrocardiographic (ECG) ST-segment elevation, whereas 2 patients with normal LV function had no ECG changes. Both of these patients had profuse collateral blood supply to the stenotic coronary artery. The echocardiographic and ECG abnormalities increased proportionately to the length of balloon occlusion. This study confirms previous animal and recent human studies of transient LV dysfunction during coronary occlusion.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 2934968     DOI: 10.1016/0002-9149(86)90944-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Left ventricular function during balloon dilatation of the aortic valve in elderly patients: a blind study of echocardiograms.

Authors:  H Egeblad; A Wennevold
Journal:  Br Heart J       Date:  1990-01

2.  Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

Authors:  M S Norell; J P Lyons; A H Gershlick; J E Gardener; M T Rothman; C A Layton; R Balcon
Journal:  Br Heart J       Date:  1988-04

3.  Changes in myocardial echo amplitude during reversible ischaemia in humans.

Authors:  D A Lythall; D G Gibson; S S Kushwaha; M S Norell; A G Mitchell; C J Ilsley
Journal:  Br Heart J       Date:  1992-05

Review 4.  Left ventricular dysfunction due to stunning and hibernation in patients.

Authors:  R Ferrari; G La Canna; R Giubbini; E Milan; C Ceconi; F de Giuli; P Berra; O Alfieri; O Visioli
Journal:  Cardiovasc Drugs Ther       Date:  1994-05       Impact factor: 3.727

5.  Sequence of electrocardiographic and acoustic cardiographic changes and angina during coronary occlusion and reperfusion in patients undergoing percutaneous coronary intervention.

Authors:  Eunyoung Lee; Barbara J Drew; Ronald H Selvester; Andrew D Michaels
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-04       Impact factor: 1.468

6.  Changes in Doppler indices of cardiac function during and after percutaneous transluminal coronary angioplasty.

Authors:  A C Hunt; S C Chow; J Escaned; R A Perry; A Seth; M F Shiu
Journal:  Br Heart J       Date:  1991-11

Review 7.  The ischaemic constellation: an alternative to the ischaemic cascade-implications for the validation of new ischaemic tests.

Authors:  Annette Maznyczka; Sayan Sen; Christopher Cook; Darrel P Francis
Journal:  Open Heart       Date:  2015-07-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.