Literature DB >> 29348700

Open-air sprays for capturing and controlling airborne float coal dust on longwall faces.

T W Beck1, C E Seaman1, M R Shahan1, S E Mischler1.   

Abstract

Float dust deposits in coal mine return airways pose a risk in the event of a methane ignition. Controlling airborne dust prior to deposition in the return would make current rock dusting practices more effective and reduce the risk of coal-dust-fueled explosions. The goal of this U.S. National Institute for Occupational Safety and Health study is to determine the potential of open-air water sprays to reduce concentrations of airborne float coal dust, smaller than 75 µm in diameter, in longwall face airstreams. This study evaluated unconfined water sprays in a featureless tunnel ventilated at a typical longwall face velocity of 3.6 m/s (700 fpm). Experiments were conducted for two nozzle orientations and two water pressures for hollow cone, full cone, flat fan, air atomizing and hydraulic atomizing spray nozzles. Gravimetric samples show that airborne float dust removal efficiencies averaged 19.6 percent for all sprays under all conditions. The results indicate that the preferred spray nozzle should be operated at high fluid pressures to produce smaller droplets and move more air. These findings agree with past respirable dust control research, providing guidance on spray selection and spray array design in ongoing efforts to control airborne float dust over the entire longwall ventilated opening.

Entities:  

Year:  2018        PMID: 29348700      PMCID: PMC5769954          DOI: 10.19150/me.7978

Source DB:  PubMed          Journal:  Min Eng        ISSN: 0026-5187


  2 in total

1.  Collection of airborne coal dust by water spray in a horizontal duct.

Authors:  T F Tomb; J E Emmerling; R H Kellner
Journal:  Am Ind Hyg Assoc J       Date:  1972-11

2.  Sampling and analysis method for measuring airborne coal dust mass in mixtures with limestone (rock) dust.

Authors:  T L Barone; J R Patts; S J Janisko; J F Colinet; L D Patts; T W Beck; S E Mischler
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

  2 in total
  2 in total

1.  Comparison of the CAS-POL and IOM samplers for determining the knockdown efficiencies of water sprays on float coal dust.

Authors:  Clara E Seaman; Michael R Shahan; Timothy W Beck; Steven E Mischler
Journal:  J Occup Environ Hyg       Date:  2018-03       Impact factor: 2.155

2.  Design of a water curtain to reduce accumulations of float coal dust in longwall returns.

Authors:  Clara E Seaman; Michael R Shahan; Timothy W Beck; Steven E Mischler
Journal:  Int J Min Sci Technol       Date:  2020-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.