Literature DB >> 29336551

First Gut Instincts Are Always Right: The Resolution Required for a Mass Defect Analysis of Polymer Ions Can Be as Low as Oligomeric.

Thierry Fouquet1, Takaya Satoh2, Hiroaki Sato1.   

Abstract

Its recent adaptation to low-resolution mass spectra of polymers using fractional base units raises the question of the minimal resolution needed for a Kendrick mass defect (KMD) analysis. Intuiting an oligomeric resolution since the mass of a repeat unit is the sole value to be known, it is challenged by the relative failure of the KMD plots computed from an isotopically resolved matrix-assisted laser desorption ionization-time-of-flight (MALDI-TOF) mass spectrum to display clear alignments in the high mass range. Another procedure based on the remainders of Kendrick mass (RKMs) overcomes this pitfall with oligomers perfectly aligned in a new RKM plot. Despite a concomitant degradation of the resolving power and accuracy, with the example of MALDI-TOF/TOF mass spectra of a variety of homo- and copolymer ions, the RKM procedure still allows a rapid enumeration, assignment, and any further manipulation of all the product ion series in visual RKM plots. Successfully extended to the critical case of a MALDI mass spectrum recorded with a linear TOF analyzer allowing a bare oligomeric resolution, the RKM plot turns the distributions differing by their end-groups or adducted ion into clear horizontal lines. It eventually gives intuition its due by answering the original question: the minimal resolution required for a mass defect analysis can be as low as oligomeric with the appropriate formulas.

Entities:  

Year:  2018        PMID: 29336551     DOI: 10.1021/acs.analchem.7b04518

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  On the Kendrick Mass Defect Plots of Multiply Charged Polymer Ions: Splits, Misalignments, and How to Correct Them.

Authors:  Thierry N J Fouquet; Robert B Cody; Yuka Ozeki; Shinya Kitagawa; Hajime Ohtani; Hiroaki Sato
Journal:  J Am Soc Mass Spectrom       Date:  2018-05-11       Impact factor: 3.109

2.  Tandem Mass-Remainder Analysis of Industrially Important Polyether Polyols.

Authors:  Mahir Hashimov; Ákos Kuki; Tibor Nagy; Miklós Zsuga; Sándor Kéki
Journal:  Polymers (Basel)       Date:  2020-11-24       Impact factor: 4.329

3.  Mass Spectral Filtering by Mass-Remainder Analysis (MARA) at High Resolution and Its Application to Metabolite Profiling of Flavonoids.

Authors:  Tibor Nagy; Gergő Róth; Ákos Kuki; Miklós Zsuga; Sándor Kéki
Journal:  Int J Mol Sci       Date:  2021-01-16       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.