Literature DB >> 29336404

Role of transesophageal echocardiography during left atrial appendage occlusion device closure in a patient with non-valvular atrial fibrillation and angiodysplasia of the colon.

Dinesh Kumar1, Sunil Kumar2, Nagraj Desai2.   

Abstract

Atrial fibrillation is the most common arrhythmia associated with significant mortality and morbidity secondary to thrombo-embolism. To prevent this thrombo-embolism oral anticoagulation therapy is the recommended treatment. In patients with contraindications to oral anticoagulation therapy, percutaneous left atrial appendage occlusion device is indicated. TEE is essential to guide in all the stages of LAA device deployment. Right from pre-procedure screening, to guiding during deployment, to rule out any complications and post-procedure surveillance and monitoring long term outcomes.

Entities:  

Mesh:

Year:  2018        PMID: 29336404      PMCID: PMC5791502          DOI: 10.4103/aca.ACA_111_17

Source DB:  PubMed          Journal:  Ann Card Anaesth        ISSN: 0971-9784


Introduction

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia encountered in clinical practice. The incidence is around 3%–5% in the age group of 65–75 years and increasing to >8% in patients more than 80 years. It is associated with increased mortality and morbidity. One of its most devastating complications is stroke secondary to thromboembolism. Overall, AF accounts for 15%–20% of strokes in the general population and for up to 30% in patients over the age group of 80 years. If untreated, the risk of stroke is 3–5%/year in patients with nonvalvular AF (NVAF).[123456] To prevent this, oral anticoagulation (OAC) is the treatment of choice.[7] This anticoagulant therapy has been proven to effectively prevent thromboembolic strokes but increases the risk of serious bleeding, which has an incidence of 2–4%/year.[8] In addition, these drugs have a small therapeutic window, several food and drug interactions, and require frequent blood testing, which makes this therapy inconvenient to many patients. Novel OACs are also associated with increased bleeding and gastric intolerance.[8] So far, neither pharmacological cardioversion nor radiofrequency catheter ablation has been proven to eliminate the indication for long-term OAC therapy.[79] Hence, alternative treatment options are essential. Left atrial appendage (LAA) occlusion device is one such option in patients where OAC is contraindicated. Transoesophageal echocardiography (TEE) plays a very important role in all the stages of LAA occlusion device therapy.

Case Report

A 71-year-old gentleman presented to us with a history suggestive of gastrointestinal (GI) bleed. When evaluated, he was found to have gastric erosion and angiodysplasia of the colon. He was a known case of diabetes, hypertension, and ischemic heart disease with percutaneous transluminal coronary angioplasty to left circumflex (LCX) 12 years back. As he developed AF during the follow-up period and CHA (2) DS2-(VASc) score >2 [Table 1],[10] he was treated with oral anticoagulant (Acitrom) and single antiplatelet therapy (Ecosprin). GI endoscopy showed gastric erosions and colonoscopy showed angiodysplasia of the colon. Two-dimensional (2D) echocardiography revealed ejection fraction - 58%, no wall motion abnormality, Grade III diastolic dysfunction, and mild tricuspid regurgitation with pulmonary hypertension (right ventricular systolic pressure - 42 mmHg). Routine blood investigation hemoglobin was 5 g/dl, and after the blood transfusion, it became 9 g/dl. Prothrombin time, and international normalized ratio were within normal limits; activated partial thromboplastin time was prolonged as the patient was on heparin. Platelet counts were within normal limits. Renal and liver functions were within normal limits. At present, as the patient was having GI bleed with anemia requiring multiple transfusions and HAS-BLED score >2 [Table 2],[11] anticoagulant therapy was contraindicated. He was posted for LAA device occlusion therapy. Percutaneously, LAA occlusion device (20 mm Amplatzer cardiac plug [ACP], St. Jude Medical Incorporation, Minnesota, USA) was deployed under general anesthesia with TEE and fluoroscopic guidance. Postoperative period was uneventful. We are describing the role of TEE in creating a roadmap to guide during LAA device occlusion therapy.
Table 1

CHA2 DS2 - (VASc) score (maximum score-9) to assess the risk of thromboembolism[10]

ConditionPoints
CHF1
Hypertension1
Age >75 years1
Diabetes1
Stroke/TIA2
Vascular disease1
Age 65-74 years1
Sex (female)1

TIA: Transient ischemic attack, CHF: Congestive heart failure

Table 2

HAS-BLED score to assess the risk of bleeding in the patient on oral anticoagulation therapy (maximum score-9)[11]

ConditionPoints
Hypertension1
Abnormal liver or renal function2
Stroke1
Bleeding1
Liable INR1
Elderly (age >65)1
Drugs or alcohol2

INR: International normalized ratio

CHA2 DS2 - (VASc) score (maximum score-9) to assess the risk of thromboembolism[10] TIA: Transient ischemic attack, CHF: Congestive heart failure HAS-BLED score to assess the risk of bleeding in the patient on oral anticoagulation therapy (maximum score-9)[11] INR: International normalized ratio

Discussion

TEE plays a very important role in all the stages of the procedure.[1213] Before deployment, TEE is used to rule out any thrombus in the left atrium or LAA as it is a contraindication for deployment of the device [Video 1]. The presence of spontaneous echocardiography contrast is not a contraindication. Preprocedure, one has to define the morphology and dimensions of LAA. Morphologically, there are four types of LAA – chicken wing, cauliflower, windsock, and cactus type.[14] One has to assess the shape and size of the ostium, the width of the “landing zone“ (area within the LAA where the device will be positioned), the length of the LAA, and, if possible, the number, shape, and location of the lobes. Lobes are better defined with cardiac computed tomography or LA angiography [Video 2]. 3D echocardiography will also better define the shape and lobes of LAA, but due to irregular heart rate, artifacts are common. Live 3D will be more useful. Baseline left atrial dimensions are measured in anteroposterior and craniocaudal plane using mid-esophageal views at sector angle 0 and 120 degrees respectively. Ostial dimensions are noted in four mid-esophageal (ME) views: (i) 0°–20° four-chamber view with slight flexion or withdrawal to open the LAA, (ii) 45°–60° aortic valve (AV) short-axis view (SAX), (iii) 90° apical two-chamber view, and (iv) 120–135° long-axis view with probe turned counterclockwise to open the subsidiary lobes. While using the ACP, the size is determined by the width of the landing zone. The LAA neck width (Landing zone) is typically measured 10-mm distal to the LAA ostium [Figure 1]. 3-5 mm more than the largest diameter should be used to size the device. LA inflow and outflow has to be assessed initially, which may get altered following the device deployment. The diameter of the left upper pulmonary vein (LUPV) and peak systolic and diastolic velocities should be noted. In the mitral valve, presence of any regurgitation and its peak velocity should be noted.
Figure 1

Left atrial appendage landing zone (neck width) measurement (a) mid-esophageal left atrial appendage view at 20°. (b) Mid-esophageal left atrial appendage view at 50°. (c) Left atrial appendage angiography right anterior oblique 30° and Cranial 30°

Left atrial appendage landing zone (neck width) measurement (a) mid-esophageal left atrial appendage view at 20°. (b) Mid-esophageal left atrial appendage view at 50°. (c) Left atrial appendage angiography right anterior oblique 30° and Cranial 30° The device is deployed using vascular access through the right femoral vein and then entering the left atrium through transseptal puncture. Most important step during the procedure is transseptal puncture. TEE is very useful in guiding the puncture. Unlike transseptal puncture for balloon mitral valvotomy, the puncture is made in the inferior and posterior part of the fossa ovalis to get better alignment with the axis of LAA. The orthogonal views ME AV SAX and bicaval views are used to guide the cardiologist during transseptal puncture [Video 3 and Figure 2]. While puncturing the septum, it should be away from the AV in ME AV SAX view and toward inferior vena cava in bicaval view. After the transseptal puncture, the patient is haparinized to maintain an ACT >250 s. TEE and contrast angiography of the LAA (right anterior oblique 30°/cranial 30°) are used to measure the LAA dimensions (ostium, neck width, and depth) – based on these measurements, the size of the device is chosen [Video 2]. The positioning of the device in the LAA cavity is ensured by TEE and fluoroscopy; the axis of the device should be in alignment with the major axis of LAA. Once in position, the device stability is confirmed by a tug test, and complete sealing is verified by color Doppler imaging with lower Nyquist limits [Video 4]. Finally, the device is released from the delivery cable, and possible complications such as compression of LUPV [Figure 3], impingement on the mitral valve, residual leak [Figure 4], and new-onset mitral regurgitation or regional wall-motion abnormality of the lateral wall due to LCX compression to be excluded [Videos 5 and 6].
Figure 2

Transoesophageal echocardiography-guided transseptal puncture. (a) Mid-esophageal bicaval view, the arrow pointing at the inferior part of the fossa ovalis. (b) Mid-esophageal aortic valve short-axis view, the arrow pointing at the posterior part of the fossa ovalis. (c) Septal puncture in inferoposterior part and catheter in the left atrium

Figure 3

Mid-esophageal left atrial appendage view showing Amplatzer cardiac plug (yellow arrow) in the left atrial appendage and normal flow in the left upper pulmonary vein (red arrow)

Figure 4

Left atrial appendage angiogram postdeployment showing no residual leak across the device and arrow is showing the stent in the left circumflex

Transoesophageal echocardiography-guided transseptal puncture. (a) Mid-esophageal bicaval view, the arrow pointing at the inferior part of the fossa ovalis. (b) Mid-esophageal aortic valve short-axis view, the arrow pointing at the posterior part of the fossa ovalis. (c) Septal puncture in inferoposterior part and catheter in the left atrium Mid-esophageal left atrial appendage view showing Amplatzer cardiac plug (yellow arrow) in the left atrial appendage and normal flow in the left upper pulmonary vein (red arrow) Left atrial appendage angiogram postdeployment showing no residual leak across the device and arrow is showing the stent in the left circumflex Various devices like WATCHMAN, AMPLATZER cardiac plug [Figure 5], and COHEREX WaveCrest are available.[17] Surgical/thoracoscopic LA appendectomy and the epicardial LARIAT suture delivery device are also described.[1516] WATCHMAN is US FDA approved device for NVAF with contraindication for OAC therapy. Various complications are described during the procedure, such as device embolism, cardiac perforation, thrombus on the left atrial side of the device, pericardial effusion, residual flow across LAA, compression of LCX artery or superior pulmonary vein, and CVA secondary to thrombus or air. As more and more patients are undergoing minimally invasive and percutaneous device closure, cardiac anesthesiologist should be well versed in echocardiographic imaging in the catheterization laboratory similar to the operating room. TEE-guided transseptal puncture will be the standard of care for left-sided interventions such as LAA device closure, balloon mitral valvuloplasty, or mitral clip.
Figure 5

Amplatzer cardiac plug [ACP], St. Jude Medical Incorporation, Minnesota, USA

Amplatzer cardiac plug [ACP], St. Jude Medical Incorporation, Minnesota, USA

Conclusion

The percutaneous LAA occlusion device has been shown to be a safe, efficacious, and cost-effective strategy for stroke prevention in patients with NVAF with an increased risk of stroke and bleeding. TEE is useful to assess the suitability of the patient for device closure, to measure the size and select the device to be deployed, to guide during transseptal puncture and deployment of the device, to assess the stability of the device following deployment, and to rule out any complication following procedure and during long-term follow-up.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  16 in total

1.  2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Europace       Date:  2012-03-01       Impact factor: 5.214

2.  A novel user-friendly score (HAS-BLED) to assess 1-year risk of major bleeding in patients with atrial fibrillation: the Euro Heart Survey.

Authors:  Ron Pisters; Deirdre A Lane; Robby Nieuwlaat; Cees B de Vos; Harry J G M Crijns; Gregory Y H Lip
Journal:  Chest       Date:  2010-03-18       Impact factor: 9.410

3.  Imaging the left atrial appendage prior to, during, and after occlusion.

Authors:  Siobhan M Lockwood; Jeffery F Alison; Manoj N Obeyesekere; Philip M Mottram
Journal:  JACC Cardiovasc Imaging       Date:  2011-03

4.  2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation--developed with the special contribution of the European Heart Rhythm Association.

Authors:  A John Camm; Gregory Y H Lip; Raffaele De Caterina; Irene Savelieva; Dan Atar; Stefan H Hohnloser; Gerhard Hindricks; Paulus Kirchhof
Journal:  Europace       Date:  2012-08-24       Impact factor: 5.214

5.  The WATCHMAN left atrial appendage closure device for atrial fibrillation.

Authors:  Sven Möbius-Winkler; Marcus Sandri; Norman Mangner; Phillip Lurz; Ingo Dähnert; Gerhard Schuler
Journal:  J Vis Exp       Date:  2012-02-28       Impact factor: 1.355

6.  Impact of atrial fibrillation on the risk of death: the Framingham Heart Study.

Authors:  E J Benjamin; P A Wolf; R B D'Agostino; H Silbershatz; W B Kannel; D Levy
Journal:  Circulation       Date:  1998-09-08       Impact factor: 29.690

7.  Left atrial appendage studied by computed tomography to help planning for appendage closure device placement.

Authors:  Yan Wang; Luigi Di Biase; Rodney P Horton; Tuan Nguyen; Prasant Morhanty; Andrea Natale
Journal:  J Cardiovasc Electrophysiol       Date:  2010-09

8.  Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study).

Authors:  C D Furberg; B M Psaty; T A Manolio; J M Gardin; V E Smith; P M Rautaharju
Journal:  Am J Cardiol       Date:  1994-08-01       Impact factor: 2.778

9.  Dabigatran versus warfarin in patients with atrial fibrillation.

Authors:  Stuart J Connolly; Michael D Ezekowitz; Salim Yusuf; John Eikelboom; Jonas Oldgren; Amit Parekh; Janice Pogue; Paul A Reilly; Ellison Themeles; Jeanne Varrone; Susan Wang; Marco Alings; Denis Xavier; Jun Zhu; Rafael Diaz; Basil S Lewis; Harald Darius; Hans-Christoph Diener; Campbell D Joyner; Lars Wallentin
Journal:  N Engl J Med       Date:  2009-08-30       Impact factor: 91.245

10.  Prevalence, incidence, prognosis, and predisposing conditions for atrial fibrillation: population-based estimates.

Authors:  W B Kannel; P A Wolf; E J Benjamin; D Levy
Journal:  Am J Cardiol       Date:  1998-10-16       Impact factor: 2.778

View more
  1 in total

1.  Vital Role of Transesophageal Echocardiographic Surveillance of a Left Atrial Appendage Perforation Complicating Attempted Percutaneous Appendage Occlusion.

Authors:  Edan Zitelny; Ryan Brunetti; Matthew Singleton; Elijah Beaty; Karl Richardson
Journal:  CASE (Phila)       Date:  2020-10-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.