Literature DB >> 29335167

Fate and hazard of the electrochemical oxidation of triclosan. Evaluation of polychlorodibenzo‑p‑dioxins and polychlorodibenzofurans (PCDD/Fs) formation.

Claudia Solá-Gutiérrez1, M Fresnedo San Román1, Inmaculada Ortiz2.   

Abstract

Triclosan (TCS) is widely used as antiseptic or preservative in many personal care products (PCPs), such as cosmetics, hand wash, toothpaste and deodorant soaps, among others. It is characterized by acute toxicity, resistance to biodegradation, environmental persistence and relatively high lipophilicity. In order to protect the environment and natural resources from the negative effects of the discharge of polluted wastewater with TCS, the application of efficient remediation technologies able to degrade the pollutant to harmless levels becomes crucial. Electrochemical oxidation, among all advanced oxidation processes (AOPs), has been reported as very effective in the complete degradation of a number of persistent pollutants; therefore, its performance using boron-doped diamond (BDD) anodes, and response to operation variables, has been studied in this work. As expected, complete degradation of TCS was achieved in all the studied conditions; however, going a step further and knowing that TCS is a precursor of polychlorinated dibenzo‑p‑dioxins and dibenzofurans (PCDD/Fs), their quantitative presence in the oxidation media has been assessed. Results showed the dominance of dichlorinated (DCDD) and trichlorinated (TrCDD/Fs) in the homologue profile of total PCDD/Fs, reaching values up to 1.48 × 105 pg L-1 in samples with initial concentration of TCS of 100 mg L-1 and NaCl as electrolyte. Under these conditions, the International Toxicity Equivalency Factor (I-TEF) achieved values up to 2.76 × 102 pg L-1. Nevertheless, the presence of copper in the oxidation medium tends to reduce I-TEF values. Finally, considering the information reported in literature, a mechanism describing the formation of low chlorinated PCDD/Fs from TCS oxidation reactions is proposed.
Copyright © 2018. Published by Elsevier B.V.

Entities:  

Keywords:  Dibenzofurans; Dibenzo‑p‑dioxins; Electrochemical oxidation; Reaction mechanisms; Triclosan

Year:  2018        PMID: 29335167     DOI: 10.1016/j.scitotenv.2018.01.082

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  2 in total

1.  Electrochemical degradation of triclosan in aqueous solution. A study of the performance of an electro-Fenton reactor.

Authors:  Josué D García-Espinoza; Irma Robles; Víctor Gil; Elías Becerril-Bravo; Jose A Barrios; Luis A Godínez
Journal:  J Environ Chem Eng       Date:  2019-08

2.  Anti-corrosion porous RuO2/NbC anodes for the electrochemical oxidation of phenol.

Authors:  Jing Ma; Guotong Qin; Wei Wei; Tianliang Xiao; Shaomin Liu; Lei Jiang
Journal:  RSC Adv       Date:  2019-06-03       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.