BACKGROUND: Post-spinal hypotension is a common maternal complication during cesarean delivery. Aortocaval compression by the gravid uterus has been assumed as a precipitating factor for post-spinal hypotension. The role of left lateral tilting position in improving maternal cardiac output after subarachnoid block (SAB) is unclear. The aim of this work is to investigate the effect of left lateral tilting on maternal hemodynamics after SAB.Entities:
Keywords: Cesarean section; Electrical cardiometry; Hypotension; Left lateral tilting; Spinal anaesthesia
Mesh:
Year: 2018 PMID: 29334907 PMCID: PMC5769501 DOI: 10.1186/s12871-018-0473-0
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Hemodynamic measurements before spinal anesthesia. Data are presented as mean (standard deviation) and median (quartiles)
| 00 | 150 | 300 | |
|---|---|---|---|
| Stroke volume (ml) | 73.2(68,78) | 73(7.6) | 73(8.7) |
| Heart rate (Bpm) | 92(89,95) | 92(89,96) | 94(91,97) |
| Cardiac output (L/min) | 6.6 (0.9) | 6.7 (0.90) | 6.8(6.1,7.6) |
| MAP (mmHg) | 76(70,83) | 77(71,83) | 76(71,83) |
| SVR (dyn.s/cm5) | 932(830,1081) | 892(809,1042) | 887(796,1013) |
MAP mean arterial blood pressure, SVR systemic vascular resistance
Fig. 1CO changes with different angles. Lines represent means. Error bars represent standard deviations. CO: cardiac output. *denotes significance compared to baseline (pre-spinal 0 degree) reading, † denotes significance compared to post-spinal 0 degree reading
Fig. 2MAP changes with different angles. Lines represent means. Error bars represent standard deviations. MAP: mean arterial pressure. *denotes significance compared to baseline (pre-spinal 0 degree) reading, † denotes significance compared to post-spinal 0 degree reading
Hemodynamic measurements after spinal anesthesia. Data are presented as mean (standard deviation) and median (quartiles)
| 00 | 150 | 300 | Delivery | |
|---|---|---|---|---|
| Stroke volume (ml) | 53(49.5,59) | 55(51,59.5) | 55(5.9) | 89(82,98.5)v |
| Heart rate (Bpm) | 102(100,110) | 114(103,120)a | 110(104,115) | 91(85,93)a |
| Cardiac output (L/min) | 5.6(4.9,6) | 6.1 (0.8)a | 6(5.4,6.5)a | 8.1 (1)a |
| MAP (mmHg) | 50(45,60) | 59(55,60)a | 58.64 (5.76)a | 71.9 (6.45)a |
| SVR (dyn.s/cm5) | 759(680,840) | 786(135) | 791(728,876) | 701(655,753) |
MAP mean arterial blood pressure, SVR systemic vascular resistance
aDenotes statistical significance compared to 00