Literature DB >> 29334198

Enzyme-Based Glucose Sensor: From Invasive to Wearable Device.

Hyunjae Lee1,2, Yongseok Joseph Hong1,2, Seungmin Baik1,2, Taeghwan Hyeon1,2, Dae-Hyeong Kim1,2.   

Abstract

Blood glucose concentration is a key indicator of patients' health, particularly for symptoms associated with diabetes mellitus. Because of the large number of diabetic patients, many approaches for glucose measurement have been studied to enable continuous and accurate glucose level monitoring. Among them, electrochemical analysis is prominent because it is simple and quantitative. This technology has been incorporated into commercialized and research-level devices from simple test strips to wearable devices and implantable systems. Although directly monitoring blood glucose assures accurate information, the invasive needle-pinching step to collect blood often results in patients (particularly young patients) being reluctant to adopt the process. An implantable glucose sensor may avoid the burden of repeated blood collections, but it is quite invasive and requires periodic replacement of the sensor owing to biofouling and its short lifetime. Therefore, noninvasive methods to estimate blood glucose levels from tears, saliva, interstitial fluid (ISF), and sweat are currently being studied. This review discusses the evolution of enzyme-based electrochemical glucose sensors, including materials, device structures, fabrication processes, and system engineering. Furthermore, invasive and noninvasive blood glucose monitoring methods using various biofluids or blood are described, highlighting the recent progress in the development of enzyme-based glucose sensors and their integrated systems.
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  diabetes; electrochemical analysis; glucose sensor; invasive glucose monitoring system; wearable device

Mesh:

Substances:

Year:  2018        PMID: 29334198     DOI: 10.1002/adhm.201701150

Source DB:  PubMed          Journal:  Adv Healthc Mater        ISSN: 2192-2640            Impact factor:   9.933


  47 in total

Review 1.  Wireless and battery-free platforms for collection of biosignals.

Authors:  Tucker Stuart; Le Cai; Alex Burton; Philipp Gutruf
Journal:  Biosens Bioelectron       Date:  2021-01-23       Impact factor: 10.618

Review 2.  Microneedles for transdermal diagnostics: Recent advances and new horizons.

Authors:  Gui-Shi Liu; Yifei Kong; Yensheng Wang; Yunhan Luo; Xudong Fan; Xi Xie; Bo-Ru Yang; Mei X Wu
Journal:  Biomaterials       Date:  2019-12-26       Impact factor: 12.479

3.  A Disposable Tear Glucose Biosensor-Part 5: Improvements in Reagents and Tear Sampling Component.

Authors:  Chi En Lin; Yuka Ito; Anna Deng; Jared Johns; Daniel Matloff; Curtiss B Cook; Koji Sode; Jeffrey T La Belle
Journal:  J Diabetes Sci Technol       Date:  2018-04-18

4.  Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications.

Authors:  Martina Vettoretti; Giacomo Cappon; Giada Acciaroli; Andrea Facchinetti; Giovanni Sparacino
Journal:  J Diabetes Sci Technol       Date:  2018-05-22

Review 5.  Electrochemical Sensors Based on Conducting Polymers for the Aqueous Detection of Biologically Relevant Molecules.

Authors:  Álvaro Terán-Alcocer; Francisco Bravo-Plascencia; Carlos Cevallos-Morillo; Alex Palma-Cando
Journal:  Nanomaterials (Basel)       Date:  2021-01-19       Impact factor: 5.076

6.  Design of an amperometric glucose oxidase biosensor with added protective and adhesion layers.

Authors:  Rongwei Gao; Xuelian Yang; Qiuju Yang; Yuanke Wu; Feng Wang; Qingyou Xia; Shu-Juan Bao
Journal:  Mikrochim Acta       Date:  2021-08-29       Impact factor: 5.833

Review 7.  Nanozyme-based colorimetric biosensor with a systemic quantification algorithm for noninvasive glucose monitoring.

Authors:  Hee-Jae Jeon; Hyung Shik Kim; Euiheon Chung; Dong Yun Lee
Journal:  Theranostics       Date:  2022-09-07       Impact factor: 11.600

8.  Modular Fabrication of Intelligent Material-Tissue Interfaces for Bioinspired and Biomimetic Devices.

Authors:  John R Clegg; Angela M Wagner; Su Ryon Shin; Shabir Hassan; Ali Khademhosseini; Nicholas A Peppas
Journal:  Prog Mater Sci       Date:  2019-07-17

Review 9.  Deep Eutectic Solvents (DESs) and Their Application in Biosensor Development.

Authors:  Rossella Svigelj; Nicolò Dossi; Cristian Grazioli; Rosanna Toniolo
Journal:  Sensors (Basel)       Date:  2021-06-22       Impact factor: 3.576

10.  Application of mycogenic silver/silver oxide nanoparticles in electrochemical glucose sensing; alongside their catalytic and antimicrobial activity.

Authors:  Sk Najrul Islam; Syed Mohd Adnan Naqvi; Sadia Parveen; Absar Ahmad
Journal:  3 Biotech       Date:  2021-06-17       Impact factor: 2.893

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.