Fast and easy extraction of antidepressants from whole blood using ionic liquids as extraction solvent.

Marieke De Boeck1, Lisa Dubrulle1, Wim Dehaen2, Jan Tytgat1, Eva Cuypers3.   

Abstract

This study aims to prove that ionic liquids (ILs) can be used as extraction solvents in a liquid-liquid microextraction, coupled to LC-MS/MS, for the quantification of a large group of antidepressants in whole blood samples. The sample preparation procedure consisted of adding 1.0mL aqueous buffer pH 3.0 and 60µL of IL (1-butyl-3-methylimidazolium hexafluorophosphate) to 1.0mL whole blood. Subsequently, a 5-min rotary mixing step was performed followed by centrifugation. The lower IL phase was collected, diluted 1:10 in methanol and 10µL was injected into the LC-MS/MS. The following analytes were included in the full-quantitative method: agomelatine, amitriptyline, bupropion, clomipramine, dosulepin, doxepin, duloxetine, escitalopram, fluoxetine, imipramine, maprotiline, mianserin, mirtazapine, nortriptyline, paroxetine, reboxetine, trazodone and venlafaxine. Selectivity was checked for 10 different whole blood matrices. Additionally, possible interferences of deuterated standards or other antidepressants were evaluated. Overall, no interferences were found. For each analyte a matrix-matched calibration curve was constructed (7 levels, n = 6), covering therapeutic and low toxic concentrations. Accuracy and precision were evaluated over eight days, at three concentration levels (n = 2). Bias, repeatability and intermediate precision results met with the proposed validation criteria, except for fluvoxamine, which was therefore only included in the semi-quantitative method. LOQs were set at the lowest calibrator concentration and LOD values were - for most analytes - within a range of 1-2ng/mL. Recoveries (RE) and matrix effects (ME) were evaluated for five types of donor whole blood, at two concentration levels. RE values were within a range of 53.11-132.98%. ME values were within a range of 61.92-123.24%. In conclusion, this study proves the applicability of ILs as extraction solvents for a large group of antidepressants in complex whole blood matrices.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antidepressants; Ionic liquid; LC-MS/MS; Liquid-liquid microextraction; Quantification; Validation

Mesh:

Substances:

Year:  2017        PMID: 29332813     DOI: 10.1016/j.talanta.2017.12.044

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  The Influence of Ionic Liquids on the Effectiveness of Analytical Methods Used in the Monitoring of Human and Veterinary Pharmaceuticals in Biological and Environmental Samples-Trends and Perspectives.

Authors:  Natalia Treder; Tomasz Bączek; Katarzyna Wychodnik; Justyna Rogowska; Lidia Wolska; Alina Plenis
Journal:  Molecules       Date:  2020-01-10       Impact factor: 4.411

2.  Carbon Nanohorn Suprastructures on a Paper Support as a Sorptive Phase.

Authors:  Julia Ríos-Gómez; Beatriz Fresco-Cala; María Teresa García-Valverde; Rafael Lucena; Soledad Cárdenas
Journal:  Molecules       Date:  2018-05-24       Impact factor: 4.411

3.  New Method for the Monitoring of Antidepressants in Oral Fluid Using Dried Spot Sampling.

Authors:  Sofia Soares; Tiago Rosado; Mário Barroso; Eugenia Gallardo
Journal:  Pharmaceuticals (Basel)       Date:  2021-12-08

4.  Development of a method for assessing the accumulation and metabolization of antidepressant drugs in zebrafish (Danio rerio) eleutheroembryos.

Authors:  Noemí Molina-Fernández; Sandra Rainieri; Riansares Muñoz-Olivas; Paloma de Oro-Carretero; Jon Sanz-Landaluze
Journal:  Anal Bioanal Chem       Date:  2021-06-30       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.