Literature DB >> 29330875

Performance of the Early Access AmpliSeq™ Mitochondrial Panel with degraded DNA samples using the Ion Torrent™ platform.

Ka Tak Wai1, Mark Barash1, Peter Gunn1.   

Abstract

The Early Access AmpliSeq™ Mitochondrial Panel amplifies whole mitochondrial genomes for phylogenetic and kinship identifications, using Ion Torrent™ technology. There is currently limited information on its performance with degraded DNA, a common occurrence in forensic samples. This study evaluated the performance of the Panel with DNA samples degraded in vitro, to mimic conditions commonly found in forensic investigations. Purified DNA from five individuals was heat-treated at five time points each (125°C for 0, 30, 60, 120, and 240 min; total n = 25). The quality of DNA was assessed via a real-time DNA assay of genomic DNA and prepared for massively parallel sequencing on the Ion Torrent™ platform. Mitochondrial sequences were obtained for all samples and had an amplicon coverage averaging between 66X to 2803X. Most amplicons (157/162) displayed high coverages (452 ± 333X), while reads with less than 100X coverage were recorded in five amplicons only (90 ± 5X). Amplicon coverage was decreased with prolonged heating. At 72% strand balance, reads were well balanced between forward and reverse strands. Using a coverage threshold of ten reads per SNP, complete sequences were recovered in all samples and resolved kinship and, haplogroup relations. Additionally, the HV1 and HV2 regions of the reference and 240-min heat-treated samples (n = 10) were Sanger-sequenced for concordance. Overall, this study demonstrates the efficacy of a novel forensic Panel that recovers high quality mitochondrial sequences from degraded DNA samples.
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Degraded DNA; Forensic; Ion Torrent PGM™; Massively parallel sequencing; Mitochondrial DNA

Mesh:

Substances:

Year:  2018        PMID: 29330875     DOI: 10.1002/elps.201700371

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  Development of the MitoQ assay as a real-time quantification of mitochondrial DNA in degraded samples.

Authors:  Ka Tak Wai; Peter Gunn; Mark Barash
Journal:  Int J Legal Med       Date:  2018-10-24       Impact factor: 2.686

Review 2.  Interpol review of forensic biology and forensic DNA typing 2016-2019.

Authors:  John M Butler; Sheila Willis
Journal:  Forensic Sci Int       Date:  2020-02-20       Impact factor: 2.395

3.  From Forensics to Clinical Research: Expanding the Variant Calling Pipeline for the Precision ID mtDNA Whole Genome Panel.

Authors:  Filipe Cortes-Figueiredo; Filipa S Carvalho; Ana Catarina Fonseca; Friedemann Paul; José M Ferro; Sebastian Schönherr; Hansi Weissensteiner; Vanessa A Morais
Journal:  Int J Mol Sci       Date:  2021-11-06       Impact factor: 5.923

Review 4.  Massively parallel sequencing techniques for forensics: A review.

Authors:  Brigitte Bruijns; Roald Tiggelaar; Han Gardeniers
Journal:  Electrophoresis       Date:  2018-08-22       Impact factor: 3.535

5.  Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel.

Authors:  Jennifer Churchill Cihlar; Christina Amory; Robert Lagacé; Chantal Roth; Walther Parson; Bruce Budowle
Journal:  Genes (Basel)       Date:  2020-11-13       Impact factor: 4.096

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.