Literature DB >> 29325136

Haemodynamic performance of AFX and Nellix endografts: a computational fluid dynamics study.

Anastasios Raptis1, Michalis Xenos1,2, George Kouvelos3, Athanasios Giannoukas1,3, Miltiadis Matsagkas1,3.   

Abstract

OBJECTIVES: The objective of this study is to analyse the flow conditions in the AFX and Nellix endografts (EGs) accounting for their postimplantation configuration in patients with an endovascular aneurysm repair-treated abdominal aortic aneurysm.
METHODS: We reconstructed post-endovascular aneurysm repair computed tomography scans of patients treated with an AFX or Nellix EG creating post-implantation EG models. We examined 16 patients, 8 in each group. The blood flow properties were obtained by computational fluid dynamics simulations and were subsequently compared with physiological infrarenal blood flow properties measured in 5 healthy subjects. Specifically, pressure drop, maximum velocity and wall shear stress were measured at peak systole and mean helicity at mid-diastole.
RESULTS: Our statistical analyses showed that the haemodynamic properties in both control regions did not vary statistically after the implantation of either the AFX or the Nellix EG, except for helicity that was significantly lower in the abdominal part of the Nellix EG compared with the expected physiological measurement. Regardless of the overall blood flow restoration, it is important to note that low pressure drop was detected along the limbs of the AFX and suppressed blood helical motion was detected at the entrance of the Nellix device.
CONCLUSIONS: It is observed from the results that the AFX EG has achieved absolute restoration of blood flow after endovascular aneurysm repair, although the development of secondary flow in the upper part of the EG and the low pressure drop in its limbs should be acknowledged. The Nellix EG also seems to be haemodynamically efficient. However, the suppression of helical flow before blood enters the device might raise concerns about its clinical application.

Entities:  

Mesh:

Year:  2018        PMID: 29325136     DOI: 10.1093/icvts/ivx414

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  3 in total

1.  Editorial: Clinical and Hemodynamic Performance of Aortic Endografts.

Authors:  Efstratios Georgakarakos
Journal:  Front Surg       Date:  2018-06-22

2.  Haemodynamic Analysis of Branched Endografts for Complex Aortic Arch Repair.

Authors:  Sampad Sengupta; Mohamad Hamady; Xiao-Yun Xu
Journal:  Bioengineering (Basel)       Date:  2022-01-18

3.  Efficiently Simulating an Endograft Deployment: A Methodology for Detailed CFD Analyses.

Authors:  Faidon Kyriakou; Craig Maclean; William Dempster; David Nash
Journal:  Ann Biomed Eng       Date:  2020-05-11       Impact factor: 3.934

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.