Literature DB >> 29324438

An improved ring removal procedure for in-line x-ray phase contrast tomography.

Lorenzo Massimi1, Francesco Brun, Michela Fratini, Inna Bukreeva, Alessia Cedola.   

Abstract

The suppression of ring artifacts in x-ray computed tomography (CT) is a required step in practical applications; it can be addressed by introducing refined digital low pass filters within the reconstruction process. However, these filters may introduce additional ringing artifacts when simultaneously imaging pure phase objects and elements having a non-negligible absorption coefficient. Ringing originates at sharp interfaces, due to the truncation of spatial high frequencies, and severely affects qualitative and quantitative analysis of the reconstructed slices. In this work, we discuss the causes of ringing artifacts, and present a general compensation procedure to account for it. The proposed procedure has been tested with CT datasets of the mouse central nervous system acquired at different synchrotron radiation facilities. The results demonstrate that the proposed method compensates for ringing artifacts induced by low pass ring removal filters. The effectiveness of the ring suppression filters is not altered; the proposed method can thus be considered as a framework to improve the ring removal step, regardless of the specific filter adopted or the imaged sample.

Entities:  

Mesh:

Year:  2018        PMID: 29324438     DOI: 10.1088/1361-6560/aaa706

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  High resolution 3D visualization of the spinal cord in a post-mortem murine model.

Authors:  Inna Bukreeva; Victor Asadchikov; Alexey Buzmakov; Marina Chukalina; Anastasya Ingacheva; Nikolay A Korolev; Alberto Bravin; Alberto Mittone; Gabriele E M Biella; Alejandra Sierra; Francesco Brun; Lorenzo Massimi; Michela Fratini; Alessia Cedola
Journal:  Biomed Opt Express       Date:  2020-03-27       Impact factor: 3.732

2.  Assessment of plaque morphology in Alzheimer's mouse cerebellum using three-dimensional X-ray phase-based virtual histology.

Authors:  Lorenzo Massimi; Nicola Pieroni; Laura Maugeri; Michela Fratini; Francesco Brun; Inna Bukreeva; Giulia Santamaria; Valentina Medici; Tino Emanuele Poloni; Claudia Balducci; Alessia Cedola
Journal:  Sci Rep       Date:  2020-07-08       Impact factor: 4.379

3.  X-ray Phase Contrast Tomography Serves Preclinical Investigation of Neurodegenerative Diseases.

Authors:  Francesca Palermo; Nicola Pieroni; Laura Maugeri; Ginevra Begani Provinciali; Alessia Sanna; Lorenzo Massimi; Maura Catalano; Margie P Olbinado; Inna Bukreeva; Michela Fratini; Antonio Uccelli; Giuseppe Gigli; Nicole Kerlero de Rosbo; Claudia Balducci; Alessia Cedola
Journal:  Front Neurosci       Date:  2020-11-09       Impact factor: 4.677

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.