Literature DB >> 29322796

Pitfalls of Contrast Enhanced Ultrasound (CEUS) in determination of breast tumor biological dignity.

V Lehotska, K Rauova, L Vanovcanova.   

Abstract

The aim of this prospective study was to identify characteristics of breast lesions on contrast enhanced ultrasound (CEUS) that can be a source of diagnostic ambiguity and cause under- or overestimation of examined breast lesions. 215 women (range 23-76 y., mean age 53.16 y) with 215 breast lesions were examined by B-mode ultrasound, followed by CEUS and core biopsy. CEUS parameters: degree of opacification, character of washout and preliminary CEUS result (suspicious, non-suspicious, uncertain) were subsequently correlated with histopathological outcomes. Observed qualitative variables, CEUS results and their analysis with respect to histological type were evaluated using Pearson χ2 square test, p<0.05 was statistically significant. Differences in mean lesion size, mean age of patients, mean size between groups (malignant/benign) with respect to CEUS result were evaluated by t-test. 215 tumors, 116 (53.93%) benign and 99 (46.05%) malignant lesions. 17 (14.66%) benign and 15 (15.15%) malignant lesions expressed atypical washout, 5 (4.31%) benign lesions had early washout and 38 (38.38%) had continuous washout (p<0.0001). 56 (48.28%) benign and 55 (55.56%) malignant lesions had middle degree of opacification, 19 (16.38%) benign had high and 5 (5.05%) malignant lesions low degree of opacification (p<0.0001). Finally, 38 (32.72%) benign and 20 (20.20%) malignant were marked CEUS uncertain. As risk lesions are considered fibroadenomas, fibrocystic lesions, papillomas and low grade DCIS or invasive breast tumors, especially lesions smaller than 10 mm.Identification of CEUS pitfalls with respect to problematic histopathologic entities can reduce the risk of misdiagnosis and improve further management of breast lesions.

Entities:  

Keywords:  benign breast tumors; contrast enhanced ultrasound; malignant breast tumors biological dignity.

Mesh:

Substances:

Year:  2018        PMID: 29322796     DOI: 10.4149/neo_2018_170116N43

Source DB:  PubMed          Journal:  Neoplasma        ISSN: 0028-2685            Impact factor:   2.575


  2 in total

1.  Values of Contrast-Enhanced Ultrasound in Classification and Diagnosis of Common Bile Duct and Superficial Organ Lesions under Compression Algorithm.

Authors:  Yezhao Li; Caihong Zhao; Minpei Qin; Xia Zhang; Haizhen Liao; Haiqing Su
Journal:  J Healthc Eng       Date:  2021-09-29       Impact factor: 2.682

2.  The role of contrast-enhanced ultrasound in the diagnosis of malignant non-mass breast lesions and exploration of diagnostic criteria.

Authors:  Fan Zhang; Lifang Jin; Gang Li; Chao Jia; Qiusheng Shi; Lianfang Du; Rong Wu
Journal:  Br J Radiol       Date:  2021-02-09       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.