Literature DB >> 29322517

Discordant human T-lymphotropic virus screening with Western blot confirmation: evaluation of the dual-test algorithm for US blood donations.

Susan L Stramer1, Rebecca L Townsend1, Gregory A Foster1, Ramona Johnson2, Barbara Weixlmann2, Roger Y Dodd3.   

Abstract

BACKGROUND: Human T-lymphotropic virus (HTLV) blood donation screening has used a dual-testing algorithm beginning with either a chemiluminescent immunoassay or enzyme-linked immunosorbent screening assay (ELISA). Before the availability of a licensed HTLV supplemental assay, repeat-reactive (RR) samples on a first assay (Assay 1) were retested with a second screening assay (Assay 2). Donors with RR results by Assay 2 were deferred from blood donation and further tested using an unlicensed supplemental test to confirm reactivity while nonreactive (NR) donors remained eligible for donation until RR on a subsequent donation. This "dual-test" algorithm was replaced in May 2016 with the requirement that all RRs by Assay 1 be further tested by a licensed HTLV supplemental test (Western blot [WB]). In this study, we have requalified the dual-test algorithm using the available licensed HTLV WB. STUDY DESIGN AND METHODS: We tested 100 randomly selected HTLV RRs on screening Assay 1 (Abbott PRISM chemiluminescent immunoassay) but NR on screening Assay 2 (Avioq ELISA) by a Food and Drug Administration-licensed WB (MP Biomedicals) to ensure that no confirmed positives were among those that were RR by Assay 1 but NR by Assay 2.
RESULTS: Of the 100 samples evaluated, 79 of 100 were WB seronegative, 21 of 100 indeterminate, and 0 of 100 seropositive. Of the 79 of 100 seronegative specimens, 73 of 79 did not express any bands on WB.
CONCLUSIONS: We demonstrated that none of the 100 samples RR on Assay 1 but NR on Assay 2 were confirmed positive. This algorithm prevents such donors from requiring further testing and from being deferred.
© 2018 AABB.

Entities:  

Mesh:

Year:  2018        PMID: 29322517     DOI: 10.1111/trf.14471

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  Comparative Evaluation and Measure of Accuracy of ELISAs, CLIAs, and ECLIAs for the Detection of HIV Infection among Blood Donors in China.

Authors:  Le Chang; Junpeng Zhao; Fei Guo; Huimin Ji; Lu Zhang; Xinyi Jiang; Lunan Wang
Journal:  Can J Infect Dis Med Microbiol       Date:  2020-08-14       Impact factor: 2.471

2.  A New Flow Cytometry-Based Single Platform for Universal and Differential Serodiagnosis of HTLV-1/2 Infection.

Authors:  Luciene Pimenta de Paiva; Jordana Grazziela Alves Coelho-Dos-Reis; Bruno Caetano Trindade; Vanessa Peruhype-Magalhães; Márcio Sobreira Silva Araújo; Juan Jonathan Gonçalves; Ana Caroline Nogueira; Júlia Pereira Martins; Ágata Lopes Ribeiro; Ana Lucia Starling; Luiz Carlos Júnior Alcântara; Maísa Aparecida Ribeiro; Anna Bárbara de Freitas Carneiro-Proietti; Ester Cerdeira Sabino; Kelly Alves Bicalho; Andréa Teixeira-Carvalho; Olindo Assis Martins-Filho
Journal:  Front Immunol       Date:  2022-04-14       Impact factor: 8.786

  2 in total