Literature DB >> 29316569

Prospective Evaluation of Posterior Fixed Zirconia Dental Prostheses: 10-Year Clinical Results.

Sven Rinke, Jens Wehle, Xenia Schulz, Ralf Bürgers, Matthias Rödiger.   

Abstract

PURPOSE: To investigate the clinical survival and success rates of conventionally luted three- and four-unit fixed dental prostheses (FDPs) with zirconia frameworks (Cercon Smart Ceramics, DeguDent) after a mean observation period of 119 ± 36 months.
MATERIALS AND METHODS: A total of 75 patients were treated in the Department of Prosthodontics at the University of Goettingen, Germany, and a total of 99 posterior FDPs were inserted and luted with zinc phosphate cement. Time-dependent survival and success rates were calculated using Kaplan-Meier curves, and their relationships with the type of veneer (ceramic), location (maxilla vs mandible), and span length (three-unit vs four-unit) were analyzed with a Cox regression model (P < .05).
RESULTS: Of the 99 inserted FDPs, 24 were lost to follow-up, 51 remained functional and passed the 10-year examination (overall survival rate: 75.0%; 95% confidence interval [CI]: 0.64, 0.85), and 13 were absolute failures caused by technical events (technical survival rate: 84%; 95% CI: 0.64, 0.85). In 50 FDPs, relative failure required a clinical intervention to maintain function (overall success rate: 40%; 95% CI: 0.29, 0.52). For 35 of these FDPs, the relative failure was caused by technical events (technical success rate: 61%; 95% CI: 0.49, 0.73). None of the evaluated factors showed an association with overall or technical survival or success.
CONCLUSION: Zirconia-based posterior FDPs produced with a first-generation computer-assisted manufacturing (CAM) system revealed high rates of absolute and relative failure, mainly due to technical events, after a mean observational period of 10 years. Further clinical studies with updated computer-assisted design (CAD)/CAM systems are needed to determine the long-term performance of zirconia-based FDPs.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29316569     DOI: 10.11607/ijp.5283

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

1.  Wear Behavior of Graded Glass/Zirconia Crowns and Their Antagonists.

Authors:  M R Kaizer; S Bano; M Borba; V Garg; M B F Dos Santos; Y Zhang
Journal:  J Dent Res       Date:  2019-02-11       Impact factor: 6.116

Review 2.  Evaluation of success rate of Zirconia based restorations: A systematic review.

Authors:  Aditee Apte; Seema Sathe; Rewa Kawade
Journal:  J Clin Exp Dent       Date:  2022-09-01

3.  Damage sensitivity of dental zirconias to simulated occlusal contact.

Authors:  Marcia Borba; Tomoyuki K Okamoto; Michelle Zou; Marina R Kaizer; Yu Zhang
Journal:  Dent Mater       Date:  2020-11-21       Impact factor: 5.304

4.  Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years.

Authors:  Ragai-Edward Matta; Constantin Motel; Elena Kirchner; Simon Paul Stelzer; Werner Adler; Manfred Wichmann; Lara Berger
Journal:  BMC Oral Health       Date:  2020-11-30       Impact factor: 2.757

5.  Evaluation of Tensile Bond Strength between Self-Adhesive Resin Cement and Surface-Pretreated Zirconia.

Authors:  Mijoo Kim; Reuben H Kim; Samuel C Lee; Thomas K Lee; Marc Hayashi; Bo Yu; Deuk-Won Jo
Journal:  Materials (Basel)       Date:  2022-04-24       Impact factor: 3.623

Review 6.  Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis.

Authors:  Babak Saravi; Andreas Vollmer; Maja Hartmann; Gernot Lang; Ralf-Joachim Kohal; Martin Boeker; Sebastian B M Patzelt
Journal:  Materials (Basel)       Date:  2021-05-20       Impact factor: 3.623

  6 in total