Literature DB >> 29316178

Evaluation of CD229 as a new alternative plasma cell gating marker in the flow cytometric immunophenotyping of monoclonal gammopathies.

Prashant R Tembhare1, Sitaram Ghogale1, Wilma Tauro1, Yajamanam Badrinath1, Nilesh Deshpande1, Shweta Kedia1, Keziah Cherian1, Nikhil V Patkar1, Gaurav Chatterjee1, Sumeet Gujral2, Papagudi G Subramanian1.   

Abstract

BACKGROUND: Current flow-cytometric plasma cell (PC) gating is based on CD138, CD38, and CD45 expression. CD138 is known for variable expression and loss during storage and processing. Introduction of anti-CD38 and anti-CD138 monoclonal-antibody therapies has limited the use of these markers during follow-up. Hence, additional reliable PC-gating markers are required. Recently, CD229 has been claimed as an alternative PC-gating marker. However, these studies are limited to a small cohort of samples. We evaluated the utility of CD229 as a new PC-gating marker in routine laboratory practice.
METHODS: Expression of CD229 was studied in 310 bone marrow (BM) samples (251 plasma-cell disorders and 59 controls) and compared with CD138 and CD38 expression. We also evaluated the effect of additional processing for cytoplasmic immunoglobulin-light-chains (CyIgL) staining on the quantitation of PC.
RESULTS: Expression of CD229 was consistently stronger on PC than other hematopoietic-cells (p < 0.001). PC-percentages using CD229 in combination with CD38 or CD138 and CD45 revealed high correlation with a reference gating-strategy using CD138, CD38 and CD45 (r = 0.98, r = 0.99 r = 0.99 respectively) and r = 0.92 using CD229 and CD45 without CD38 or CD138. In contrast, CD138 expression showed significant variability (CV-MFI, 97.5) and loss from PC in 53% of samples. Quantitation of PC was found to be lower in 69.3% and higher in 30.7% samples processed for CyIgL-staining as compared to surface-staining.
CONCLUSIONS: CD229 is a reliable new alternative PC-gating marker in routine laboratory practice. Quantitation of PC based on CD138 expression or from samples processed for CyIgL-staining should be used with caution.
© 2018 International Clinical Cytometry Society. © 2018 International Clinical Cytometry Society.

Entities:  

Keywords:  CD229; monoclonal gammopathies; plasma cell gating marker

Mesh:

Substances:

Year:  2018        PMID: 29316178     DOI: 10.1002/cyto.b.21619

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  3 in total

1.  Re: Primary Plasma Cell Leukaemia: Case report and review of the literature.

Authors:  Vitorino M Dos Santos
Journal:  Sultan Qaboos Univ Med J       Date:  2019-03-28

2.  Immunophenotypic Characterization and Ploidy Analysis of Neoplastic Plasma Cells by Multiparametric Flow Cytometry.

Authors:  R Gupta; P Gupta; K Rahman; S Biswas; D Chandra; M K Singh; M K Sarkar; A Gupta; S Nityanand
Journal:  Indian J Hematol Blood Transfus       Date:  2021-08-10       Impact factor: 0.915

3.  CD319 (SLAMF7) an alternative marker for detecting plasma cells in the presence of daratumumab or elotuzumab.

Authors:  Kah Teong Soh; Joseph D Tario; Theresa Hahn; Jens Hillengass; Philip L McCarthy; Paul K Wallace
Journal:  Cytometry B Clin Cytom       Date:  2020-10-05       Impact factor: 3.248

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.