Literature DB >> 29314157

Determination of cycloserine in microdialysis samples using liquid chromatography-tandem mass spectrometry with benzoyl chloride derivatization.

Wenjing Zhang1, Sihui Wan1,2, Lizhi Chen1, Xuebin Wang1, Zhuo Wang1, Yi Huang3.   

Abstract

A new method for the analysis of cycloserine (4-amino-3-isoxazolidinone, CYC) in rat microdialysis samples has been developed. This method consists of derivatizing the CYC with benzoyl chloride, which transforms primary amines into highly stable derivatives. An attractive feature of this method was that the derivatization reaction is straightforward and can be completed within 10 min. The formed derivative, in contrast to the non-derivatized analyte, exhibited increased chromatographic retention and decreased matrix effects resulting from the co-elution of other components using reversed-phase liquid chromatography and on-line switching. Detection on a quadrupole-linear ion trap mass spectrometer (AB3200 Q-Trap) was performed using electrospray tandem mass spectrometry in multiple reaction monitoring mode. Various derivatization parameters were optimized in order to improve chromatographic separation and minimize ion suppression. In particular, the benzoylation reaction was improved to enhance the reproducibility and sensitivity of the chromatographic method. The transition m/z 207.1 → 105.1 was acquired to monitor the CYC derivatization products. The method was fully validated for its sensitivity, selectivity, matrix effect and stability. A good linearity over the selected range (r > 0.99, range = 22-2200 mg/L), as well as accuracy and precision within ±7% of the target values, was obtained. The assay described herein was successfully applied to quantitatively measure CYC in the lung and blood of anesthetized rats.
Copyright © 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  HPLC-MS/MS; cycloserine; derivatization; microdialysis; pharmacokinetics

Mesh:

Substances:

Year:  2018        PMID: 29314157     DOI: 10.1002/bmc.4187

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  1 in total

1.  Determination of d-Cycloserine Impurities in Pharmaceutical Dosage Forms: Comparison of the International Pharmacopoeia HPLC-UV Method and the DOSY NMR Method.

Authors:  Damjan Makuc; Živa Švab; Katerina Naumoska; Janez Plavec; Zdenko Časar
Journal:  Molecules       Date:  2020-04-07       Impact factor: 4.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.