Literature DB >> 29313454

A Multicenter Experience With a New Fenestrated-Branched Device for Endovascular Repair of Thoracoabdominal Aortic Aneurysms.

Marwan Youssef1, Sebastien Deglise2, Piotr Szopinski3, Schäfer Jost-Philipp4, Amer Jomha5, Christian F Vahl1, Ahmed Koshty6.   

Abstract

PURPOSE: To investigate the outcomes of patients who were treated for thoracoabdominal aortic aneurysms (TAAAs) using custom-made fenestrated-branched stent-grafts.
METHODS: A consecutive series of 108 patients (mean age 73.5 years; 73 men) with TAAA were treated with E-xtra Design Engineering customized fenestrated-branched stent-grafts between November 2011 and January 2017. Data on baseline characteristics, procedures, and clinical follow-up were collected from 6 regional European surgical centers for retrospective analysis of endoleaks, reinterventions, and target vessel patency. The median aneurysm diameter was 6.75 cm (range 5.5-13). The distribution of the TAAA according to the modified Crawford classification of extent was 25 (24%) type I, 19 (17%) type II, 20 (18%) type III, 29 (27%) type IV, and 15 (14%) type V.
RESULTS: Technical success was achieved in 95% (103/108) of cases. Major early perioperative complications occurred in 40 (37%) patients. The 30-day mortality was 9.2% (10/108), and perioperative spinal cord ischemia was observed in 6 (5.5%) patients [2 (1.8%) permanent]. During the mean follow-up of 17.6 months (range 3-52), 28 (26%) patients required late reintervention. Two patients died due to aneurysm- or procedure-related causes. The estimated survival rates at 1, 2, and 4 years were 87%, 84%, and 51%, respectively. The estimated target vessel patency rates at the same time points were 95%, 91%, and 90%, respectively. The freedom from reintervention estimates were 84% and 73% at 1 and 4 years, respectively.
CONCLUSION: Endovascular repair of TAAA using Jotec customized fenestrated-branched stent-grafts appears to be safe and effective in the early to midterm. The considerable rate of secondary interventions indicates that further improvements, graft surveillance, and follow-up are required.

Entities:  

Keywords:  branched stent-graft; complications; endoleak; endovascular repair; fenestrated stent-graft; morbidity; mortality; reinterventions; spinal cord ischemia; thoracoabdominal aortic aneurysm

Mesh:

Year:  2018        PMID: 29313454     DOI: 10.1177/1526602817752147

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

Review 1.  Endovascular repair for thoracoabdominal aortic aneurysms: current status and future challenges.

Authors:  Emanuel R Tenorio; Marina F Dias-Neto; Guilherme Baumgardt Barbosa Lima; Anthony L Estrera; Gustavo S Oderich
Journal:  Ann Cardiothorac Surg       Date:  2021-11

2.  Hybrid three-stage repair of mega-aortic syndrome with the Lupiae technique: 10-year results.

Authors:  Giampiero Esposito; Giangiuseppe Cappabianca; Cesare Beghi; Antonio M Cricco; Cataldo Memmola; Samuele Bichi; Matteo Miccoli; Massimiliano Conte; Gaetano Contegiacomo
Journal:  Ann Cardiothorac Surg       Date:  2018-05
  2 in total