Literature DB >> 29310817

Dental implant navigation system guide the surgery future.

Ting-Mao Sun1, Ting-Hsun Lan2, Chin-Yun Pan1, Huey-Er Lee3.   

Abstract

No study has investigated the effect of learning curves on the accuracy of dental implant navigation systems. This study evaluated the accuracy of the dental implant navigation system and established the learning curve according to operation site and operating time. Each dental model was used for drilling 3 missing tooth positions, and a patient tracking module was created. The same dentist performed the drilling test for 5 sets of dental models. CT back scanning was performed on the dental models. Customized implants based on the drilled holes were inserted. The relative error between the preoperative planning and actual implant was calculated. Using the dental navigation system could help dentists position implants more accurately. Increasing the frequency with which a dentist used the navigation system resulted in shorter operations. Longitudinal and angular deviation were significantly (P < 0.0001 and P = 0.0164). We found that the same level of accuracy could be obtained for the maxilla and mandible implants. The Student's t test demonstrated that the longitudinal error, but not the total or angular error, differed significantly (P = 0.0012). The learning curve for the dental implant navigation system exhibited a learning plateau after 5 tests. The current system exhibited similar accuracy for both maxillary and mandibular dental implants in different dental locations. The one-way ANOVA revealed that the total, longitudinal, and angular errors differed significantly (P < 0.0001, P < 0.0001 and P = 0.0153). In addition, it possesses high potential for future use in dental implant surgery and its learning curve can serve as a reference for dentists.
Copyright © 2017. Published by Elsevier Taiwan.

Entities:  

Keywords:  Accuracy; Dental navigation system; Learning curve

Mesh:

Substances:

Year:  2017        PMID: 29310817     DOI: 10.1016/j.kjms.2017.08.011

Source DB:  PubMed          Journal:  Kaohsiung J Med Sci        ISSN: 1607-551X            Impact factor:   2.744


  8 in total

Review 1.  Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis.

Authors:  Adrià Jorba-García; Albert González-Barnadas; Octavi Camps-Font; Rui Figueiredo; Eduard Valmaseda-Castellón
Journal:  Clin Oral Investig       Date:  2021-02-26       Impact factor: 3.573

2.  Comparison of implant placement accuracy in two different preoperative digital workflows: navigated vs. pilot-drill-guided surgery.

Authors:  Johannes Spille; Feilu Jin; Christian Flörke; Jörg Wiltfang; Eleonore Behrens; Yahya Açil; Jürgen Lichtenstein; Hendrik Naujokat; Aydin Gülses
Journal:  Int J Implant Dent       Date:  2021-04-30

Review 3.  Current state of dynamic surgery. A literature review.

Authors:  A Parra-Tresserra; J Marquès-Guasch; J Ortega-Martínez; J Basilio-Monné; F Hernández-Alfaro
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2021-09-01

4.  Computer-Assisted Dental Implant Placement Following Free Flap Reconstruction: Virtual Planning, CAD/CAM Templates, Dynamic Navigation and Augmented Reality.

Authors:  Santiago Ochandiano; David García-Mato; Alba Gonzalez-Alvarez; Rafael Moreta-Martinez; Manuel Tousidonis; Carlos Navarro-Cuellar; Ignacio Navarro-Cuellar; José Ignacio Salmerón; Javier Pascau
Journal:  Front Oncol       Date:  2022-01-28       Impact factor: 6.244

5.  Design and Evaluation of Web-Based Dental Implant Registry (DIR) for Better Clinical Outcomes.

Authors:  Roya Naemi; Majid Jangi; Hamid Reza Barikani; Leila Shahmoradi
Journal:  Int J Biomater       Date:  2022-02-11

6.  The influence of dental experience on a dental implant navigation system.

Authors:  Ting-Mao Sun; Huey-Er Lee; Ting-Hsun Lan
Journal:  BMC Oral Health       Date:  2019-10-17       Impact factor: 2.757

7.  Comparing Accuracy of Implant Installation with a Navigation System (NS), a Laboratory Guide (LG), NS with LG, and Freehand Drilling.

Authors:  Ting-Mao Sun; Huey-Er Lee; Ting-Hsun Lan
Journal:  Int J Environ Res Public Health       Date:  2020-03-22       Impact factor: 3.390

8.  Reliability and accuracy of dynamic navigation for zygomatic implant placement.

Authors:  Yiqun Wu; Baoxin Tao; Kengliang Lan; Yihan Shen; Wei Huang; Feng Wang
Journal:  Clin Oral Implants Res       Date:  2022-02-15       Impact factor: 5.021

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.