BACKGROUND: Tumor prostheses are established as a standard procedure in tumors of the lower extremities. Septic and aseptic loosening remains the main reason for the failure of tumor prostheses. Due to bone defects, the possibilities of anchoring revision prostheses are limited. Trabecular metal cones are established in prosthetic revision surgery. However, the use of segmental trabecular metal cones in a custom-made tumor revision prosthesis has not yet been described.
OBJECTIVE: A 58-year-old patient, who initially received a resection of the distal femur and reconstruction with a tumor prosthesis due to chondrosarcoma, attended our clinic. Because of aseptic loosening of this tumor prosthesis, revision surgery was indicated.
METHODS: On account of huge bone defects, a reconstruction using a modular standard prosthesis was not possible. In order to prevent further resection of the bone and not replace the total femur, a custom-made revision tumor prosthesis was implanted.
RESULTS: After preoperative planning and explantation of the loosened prosthesis, a partially cemented custom-made revision tumor prosthesis was successfully implanted using a Revitan® Curved revision stem with a custom-made Revitan® -Taperadapter and a custom-made segmental trabecular metal cone connected to a custom-made titanium segmental distal femur and a Zimmer® NexGen® RH Knee Tibia with a straight stem (Zimmer, Inc., USA).
CONCLUSIONS: The application of segmental trabecular metal in a custom-made revision tumor prosthesis offers a new option to the previously existing treatment strategies.

Entities:  

Keywords:  Revision tumor prosthesis; bone defect; custom-made; revision total knee arthroplasty; segmental trabecular metal cones

Mesh:

Year:  2018        PMID: 29309041     DOI: 10.3233/THC-170895

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  2 in total

1.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  First application of 3D design custom-made uncemented prosthetic stem for distal femoral cemented megaprosthesis revision.

Authors:  Li Min; Kai Yao; Minxun Lu; Yong Zhou; Jie Wang; Fan Tang; Wenli Zhang; Yi Luo; Hong Duan; Chongqi Tu
Journal:  Precis Clin Med       Date:  2018-08-22