CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

Victoria Higgins1, Dorothy Truong2, Amy Woroch3, Man Khun Chan3, Houman Tahmasebi1, Khosrow Adeli4.   

Abstract

BACKGROUND: Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho).
METHODS: Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort.
RESULTS: RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO2 did not meet statistical criteria for transference (r2<0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported.
CONCLUSIONS: This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI.
Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biochemical markers; CALIPER; Ortho; Pediatric; Reference intervals

Mesh:

Substances:

Year:  2018        PMID: 29307782     DOI: 10.1016/j.clinbiochem.2017.12.011

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  4 in total

1.  Age- and Sex-Specific Reference Intervals for Myocardial Enzyme Activity in Healthy Chinese Han Population Aged 1∼<18 years.

Authors:  Wenjia Guo; Qi Zhou; Yanan Jia; Jiancheng Xu
Journal:  Biomed Res Int       Date:  2019-12-23       Impact factor: 3.411

2.  Reference intervals for 26 common biochemical analytes in term neonates in Jilin Province, China.

Authors:  Kaijin Wang; Xuetong Zhu; Qi Zhou; Jiancheng Xu
Journal:  BMC Pediatr       Date:  2021-03-31       Impact factor: 2.125

3.  Age- and Sex-Specific Pediatric Reference Intervals of Serum Electrolytes in Jilin Province of China Using the A Priori Approach.

Authors:  Xuetong Zhu; Kaijin Wang; Qi Zhou; Wenjia Guo; Yanan Jia; Jiancheng Xu
Journal:  Am J Clin Pathol       Date:  2020-10-13       Impact factor: 2.493

4.  Reference ranges for clinical electrophysiology of vision.

Authors:  C Quentin Davis; Ruth Hamilton
Journal:  Doc Ophthalmol       Date:  2021-04-21       Impact factor: 2.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.