Literature DB >> 29304280

Detection of Cyanobacteria in Eutrophic Water Using a Portable Electrocoagulator and NanoGene Assay.

Eun-Hee Lee1, Beelee Chua2, Ahjeong Son1.   

Abstract

We have demonstrated the detection of cyanobacteria in eutrophic water samples using a portable electrocoagulator and NanoGene assay. The electrocoagulator is designed to preconcentrate cyanobacteria from water samples prior to analysis via NanoGene assay. Using Microcystis aeruginosa laboratory culture and environmental samples (cell densities ranging from 1.7 × 105 to 4.1 × 106 and 6.5 × 103 to 6.6 × 107 cells·mL-1, respectively), the electrocoagulator was evaluated and compared with a conventional centrifuge. Varying the operation duration from 0 to 300 s with different cell densities was first investigated. Preconcentration efficiencies (obtained via absorbance measurement) and dry cell weight of preconcentrated cyanobacteria were then obtained and compared. For laboratory samples at cell densities from 3.2 × 105 to 4.1 × 106 cells·mL-1, the preconcentration efficiencies of electrocoagulator appeared to be stable at ∼60%. At lower cell densities (1.7 and 2.2 × 105 cells·mL-1), the preconcentration efficiencies decreased to 33.9 ± 0.2 and 40.4 ± 5.4%, respectively. For environmental samples at cell densities of 2.7 × 105 and 6.6 × 107 cells·mL-1, the electrocoagulator maintained its preconcentration efficiency at ∼60%. On the other hand, the centrifuge's preconcentration efficiencies decreased to nondetectable and below 40%, respectively. This shows that the electrocoagulator outperformed the centrifuge when using eutrophic water samples. Finally, the compatibility of the electrocoagulator with the NanoGene assay was verified via the successful detection of the microcystin synthetase D (mcyD) gene in environmental samples. The viability of the electrocoagulator as an in situ compatible alternative to the centrifuge is also discussed.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29304280     DOI: 10.1021/acs.est.7b05055

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  2 in total

1.  Ozonation enhancement of low cost double-stranded DNA binding dye based fluorescence measurement of total bacterial load in water.

Authors:  Jiwon Choi; Beelee Chua; Ahjeong Son
Journal:  RSC Adv       Date:  2021-01-21       Impact factor: 3.361

2.  The Implications of Fragmented Genomic DNA Size Range on the Hybridization Efficiency in NanoGene Assay.

Authors:  Xiaofang Wang; Beelee Chua; Ahjeong Son
Journal:  Sensors (Basel)       Date:  2018-08-13       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.