Literature DB >> 29302136

In Vitro Comparison of Two Barbed Suture Configurations for Flexor Tendon Repair.

Jamie L Engel1, Joseph N Gabra2, Andrew R Esterle1, William D Lanzinger1, John J Elias2.   

Abstract

Purpose  The current study compares the strength of a previously studied technique for flexor tendon repair with barbed sutures to an experimental approach that aligns all the barbs to oppose distraction. Methods  Twelve flexor tendons from cadaveric specimens were mechanically tested following repair of simulated zone II tendon injuries. Two repair techniques utilizing barbed sutures were studied: the Marrero-Amadeo four-core barbed suture approach and the experimental configuration with all barbs on four cores opposing distraction. Maximum applied load at failure, that is, ultimate load, and 2-mm gap force were compared between the two repair techniques, both as raw values and after normalization to cross-sectional area of the intact tendon. Statistical testing was performed using t -tests and Mann-Whitney U -tests, where appropriate, with a significance level of 0.05. Results  The ultimate loads, raw (58.2 N) and normalized (4.8 N/mm 2 ), were significantly larger for the Marrero-Amadeo repair than the proposed experimental approach (35.6 N and 2.7 N/mm 2 ; p  < 0.05). No significant differences were identified for 2-mm gap force. Conclusion  The innovation of suturing to align all barbs to oppose distraction does not improve strength of the repaired tendon. The Marrero-Amadeo technique was found to have superior strength for use in traumatic zone II flexor tendon injuries.

Entities:  

Keywords:  barbed suture; flexor tendon repair; mechanical testing; strength

Year:  2017        PMID: 29302136      PMCID: PMC5741403          DOI: 10.1055/s-0037-1606628

Source DB:  PubMed          Journal:  J Hand Microsurg        ISSN: 0974-3227


  23 in total

1.  Flexor Tendon Injuries: I. Foundations of Treatment.

Authors: 
Journal:  J Am Acad Orthop Surg       Date:  1995-01       Impact factor: 3.020

2.  No man's land revisited: the primary flexor tendon repair controversy.

Authors:  William L Newmeyer; Paul R Manske
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

3.  Flexor tendon repair with a knotless barbed suture: a comparative biomechanical study.

Authors:  Ian C Marrero-Amadeo; Aakash Chauhan; Stuart J Warden; Gregory A Merrell
Journal:  J Hand Surg Am       Date:  2011-06-12       Impact factor: 2.230

4.  A knotless flexor tendon repair technique using a bidirectional barbed suture: an ex vivo comparison of three methods.

Authors:  W Thomas McClellan; Matthew J Schessler; David S Ruch; L Scott Levin; Richard D Goldner
Journal:  Plast Reconstr Surg       Date:  2011-10       Impact factor: 4.730

5.  Two-, four-, and six-strand zone II flexor tendon repairs: an in situ biomechanical comparison using a cadaver model.

Authors:  R T Thurman; T E Trumble; D P Hanel; A F Tencer; P K Kiser
Journal:  J Hand Surg Am       Date:  1998-03       Impact factor: 2.230

6.  Comparing Biomechanical Properties, Repair Times, and Value of Common Core Flexor Tendon Repairs.

Authors:  Aakash Chauhan; Patrick Schimoler; Mark C Miller; Alexander Kharlamov; Gregory A Merrell; Bradley A Palmer
Journal:  Hand (N Y)       Date:  2017-04-19

7.  The effect of core suture flexor tendon repair techniques on gliding resistance during static cycle motion and load to failure: a human cadaver study.

Authors:  T Moriya; M C Larson; C Zhao; K-N An; P C Amadio
Journal:  J Hand Surg Eur Vol       Date:  2011-10-10

8.  A knotless bidirectional-barbed tendon repair is inferior to conventional 4-strand repairs in cyclic loading.

Authors:  F P O'Brien; B G Parks; M A Tsai; K R Means
Journal:  J Hand Surg Eur Vol       Date:  2016-03-02

9.  Zone-II flexor tendon repair: a randomized prospective trial of active place-and-hold therapy compared with passive motion therapy.

Authors:  Thomas E Trumble; Nicholas B Vedder; John G Seiler; Douglas P Hanel; Edward Diao; Sarah Pettrone
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

10.  Tensile strength of flexor tendon repair using barbed suture material in a dynamic ex vivo model.

Authors:  Philip H Zeplin; M Henle; R K Zahn; R H Meffert; K Schmidt
Journal:  J Hand Microsurg       Date:  2012-04-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.