Literature DB >> 29300699

A Self-Calibrated Tissue Viability Sensor for Free Flap Monitoring.

Melissa Berthelot, Guang-Zhong Yang, Benny Lo.   

Abstract

In fasciocutaneous free flap surgery, close postoperative monitoring is crucial for detecting flap failure, as around 10% of cases require additional surgery due to compromised anastomosis. Different biochemical and biophysical techniques have been developed for continuous flap monitoring, however, they all have shortcoming in terms of reliability, elevated cost, potential risks to the patient, and inability to adapt to the patient's phenotype. A wearable wireless device based on near infrared spectroscopy has been developed for continuous blood flow and perfusion monitoring by quantifying tissue oxygen saturation (). This miniaturized and low-cost device is designed for postoperative monitoring of flap viability. With self-calibration, the device can adapt itself to the characteristics of the patients' skin such as tone and thickness. An extensive study was conducted with 32 volunteers. The experimental results show that the device can obtain reliable measurements across different phenotypes (age, sex, skin tone, and thickness). To assess its ability to detect flap failure, the sensor was tested in a pilot animal study. Free groin flaps were performed on 16 Sprague Dawley rats. Results demonstrate the accuracy of the sensor in assessing flap viability and identifying the origin of failure (venous or arterial thrombosis).

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29300699     DOI: 10.1109/JBHI.2017.2773998

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  4 in total

1.  Use of Near-infrared Spectroscopy and Implantable Doppler for Postoperative Monitoring of Free Tissue Transfer for Breast Reconstruction: A Systematic Review and Meta-analysis.

Authors:  Melissa Berthelot; James Ashcroft; Piers Boshier; Judith Hunter; Francis Patrick Henry; Benny Lo; Guang-Zhong Yang; Daniel Leff
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-10-29

2.  Pervasive wearable device for free tissue transfer monitoring based on advanced data analysis: clinical study report.

Authors:  Melissa Berthelot; Francis Patrick Henry; Judith Hunter; Daniel Leff; Simon Wood; Navid Jallali; Elizabeth Dex; Ladislava Lysakova; Benny Lo; Guang-Zhong Yang
Journal:  J Biomed Opt       Date:  2019-06       Impact factor: 3.170

3.  Portable Medical Suction and Aspirator Devices: Are the Design and Performance Standards Relevant?

Authors:  Saketh R Peri; Forhad Akhter; Robert A De Lorenzo; R Lyle Hood
Journal:  Sensors (Basel)       Date:  2022-03-25       Impact factor: 3.576

4.  Free Myocutaneous Flap Assessment in a Rat Model: Verification of a Wireless Bioelectrical Impedance Assessment (BIA) System for Vascular Compromise Following Microsurgery.

Authors:  Yao-Kuang Huang; Min Yi Wong; Chi-Rung Wu; Yung-Ze Cheng; Bor-Shyh Lin
Journal:  J Pers Med       Date:  2021-05-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.