Literature DB >> 29298259

The Accuracy of the Alpha Defensin Lateral Flow Device for Diagnosis of Periprosthetic Joint Infection: Comparison with a Gold Standard.

Thorsten Gehrke1, Christian Lausmann1, Mustafa Citak1, Tommaso Bonanzinga1, Lars Frommelt1, Akos Zahar1.   

Abstract

BACKGROUND: Alpha defensin is a new biomarker that has been shown to have a very high accuracy to rule out periprosthetic joint infection. Recently, a new rapid lateral flow version of the alpha defensin test was developed and introduced to detect high levels of alpha defensin in synovial fluid quickly and with ease. We conducted a single-center prospective clinical study to compare the results of the Synovasure Alpha Defensin Test with those of the Musculoskeletal Infection Society (MSIS) criteria, which are considered to be the gold standard for diagnosing periprosthetic joint infection.
METHODS: A total of 223 consecutive patients with pain after total hip arthroplasty or total knee arthroplasty were enrolled into the study. In all patients, blood C-reactive protein was measured and joint aspirations were performed. From the synovial fluid, a leukocyte cell count with granulocyte percentage, microbiology cultures, and leukocyte esterase tests were carried out according to the recommendation of the MSIS for diagnosing periprosthetic joint infection. Concurrently, the Synovasure Alpha Defensin Test with a lateral flow device was performed from the aspirate. In the final clinical and statistical evaluation, 191 subjects with 195 joint aspirations (96 hips and 99 knees) were included. According to the MSIS criteria, there were 119 joints with an aseptic revision and 76 joints with periprosthetic joint infection.
RESULTS: After statistical analysis, the overall sensitivity of the Synovasure Alpha Defensin Test was 92.1% (95% confidence interval [CI], 83.6% to 97.1%), the specificity was 100% (95% CI, 97.0% to 100%), the positive predictive value was 100% (95% CI, 94.9% to 100%), and the negative predictive value was 95.2% (95% CI, 89.9% to 98.2%). The overall accuracy of the Synovasure test was 96.9% (95% CI, 93.4% to 98.9%), 189 of 195 cases.
CONCLUSIONS: Our results suggest that the Synovasure periprosthetic joint infection test has a very high accuracy in diagnosing periprosthetic infections after total hip arthroplasty or total knee arthroplasty. Although the Synovasure Alpha Defensin Test does not provide information on the identity of the infectious pathogen, the test does have an important role in recognizing periprosthetic joint infection early and enables surgeons to start proper therapy without delay. LEVEL OF EVIDENCE: Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29298259     DOI: 10.2106/JBJS.16.01522

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

1.  Laboratory-based versus qualitative assessment of α-defensin in periprosthetic hip and knee infections: a systematic review and meta-analysis.

Authors:  Giovanni Balato; Vincenzo de Matteo; Tiziana Ascione; Sigismondo Luca Di Donato; Cristiano De Franco; Francesco Smeraglia; Andrea Baldini; Massimo Mariconda
Journal:  Arch Orthop Trauma Surg       Date:  2019-07-12       Impact factor: 3.067

2.  What Is the Diagnostic Accuracy of Alpha-Defensin and Leukocyte Esterase Test in Periprosthetic Shoulder Infection?

Authors:  Niklas Unter Ecker; Alina Koniker; Thorsten Gehrke; Jochen Salber; Akos Zahar; Moritz Hentschke; Mustafa Citak
Journal:  Clin Orthop Relat Res       Date:  2019-07       Impact factor: 4.176

Review 3.  New developments and future challenges in prevention, diagnosis, and treatment of prosthetic joint infection.

Authors:  Benjamin F Ricciardi; Gowrishankar Muthukrishnan; Elysia A Masters; Nathan Kaplan; John L Daiss; Edward M Schwarz
Journal:  J Orthop Res       Date:  2020-01-31       Impact factor: 3.494

4.  Does the Alpha Defensin ELISA Test Perform Better Than the Alpha Defensin Lateral Flow Test for PJI Diagnosis? A Systematic Review and Meta-analysis of Prospective Studies.

Authors:  Jesse W P Kuiper; Steven J Verberne; Stan J Vos; Pim W van Egmond
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

5.  Assessment of a Multiplex Serological Test for the Diagnosis of Prosthetic Joint Infection: a Prospective Multicentre Study.

Authors:  Pascale Bémer; Céline Bourigault; Anne Jolivet-Gougeon; Chloé Plouzeau-Jayle; Carole Lemarie; Rachel Chenouard; Anne-Sophie Valentin; Sandra Bourdon; Anne-Gaëlle Leroy; Stéphane Corvec
Journal:  J Bone Jt Infect       Date:  2020-03-30

6.  Preliminary evaluation of a rapid lateral flow calprotectin test for the diagnosis of prosthetic joint infection.

Authors:  Alexander J Trotter; Rachael Dean; Celia E Whitehouse; Jarle Mikalsen; Claire Hill; Roxanne Brunton-Sim; Gemma L Kay; Majeed Shakokani; Alexander Z E Durst; John Wain; Iain McNamara; Justin O'Grady
Journal:  Bone Joint Res       Date:  2020-06-08       Impact factor: 5.853

7.  Qualitative Alpha-defensin Versus The Main Available Tests For The Diagnosis Of Periprosthetic Joint Infection: Best Predictor Test?

Authors:  Giovanni Riccio; Luca Cavagnaro; Wassim Akkouche; Giuliana Carrega; Lamberto Felli; Giorgio Burastero
Journal:  J Bone Jt Infect       Date:  2018-07-27

8.  Brucella Periprosthetic Joint Infection Involving Bilateral Knees with Negative Synovial Fluid Alpha-Defensin.

Authors:  Abdullah Balkhair; Sultan Al Maskari; Shadin Ibrahim; Ibrahim Al Busaidi; Mohammed Al Amin; Hashim Ba Taher
Journal:  Case Rep Infect Dis       Date:  2019-07-14

Review 9.  Laboratory testing of extravascular body fluids: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Part II - Synovial fluid.

Authors:  Anja Jokic; Lara Milevoj Kopcinovic; Jelena Culej; Irena Kocijan; Marija Bozovic
Journal:  Biochem Med (Zagreb)       Date:  2020-08-05       Impact factor: 2.313

10.  A comparative study of intraoperative frozen section and alpha defensin lateral flow test in the diagnosis of periprosthetic joint infection.

Authors:  Irene K Sigmund; Johannes Holinka; Susanna Lang; Sandra Stenicka; Kevin Staats; Gerhard Hobusch; Bernd Kubista; Reinhard Windhager
Journal:  Acta Orthop       Date:  2019-01-23       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.