Literature DB >> 2929405

Regional distribution of lung perfusion and ventilation in patients with chronic congestive heart failure and its relationship to cardiopulmonary hemodynamics.

Z Mohsenifar1, D K Amin, P K Shah.   

Abstract

To study the relationship between the distribution of pulmonary blood flow, pulmonary ventilation, and pulmonary capillary wedge pressure, we studied six patients with chronic congestive heart failure (CHF) (New York Heart Association classes II and III) at rest and during exercise. We used krypton 81m (81mKr) and technetium 99m (99mTc) to assess lung ventilation and perfusion at rest and during exercise. Hemodynamic measurements were obtained with a balloon floatation thermodilution catheter. At rest, the upper lung zones of patients with CHF received significantly higher proportions of the blood flow compared with previously published data in normal volunteers. During exercise, however, the fractional perfusion to apices did not change, which suggests that apical flow redistribution is already maximized at rest. Measured pulmonary capillary wedge pressure failed to correlate with the upper zone or the ratio of upper-to-lower zone perfusion counts. Our findings suggest that upper zone flow redistribution may be associated with high, normal, or low capillary wedge pressure and therefore does not correlate with the pulmonary capillary wedge pressure in patients with chronic CHF.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2929405     DOI: 10.1016/0002-8703(89)90628-5

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  6 in total

Review 1.  Origin of symptoms in chronic heart failure.

Authors:  A L Clark
Journal:  Heart       Date:  2005-09-13       Impact factor: 5.994

2.  Impaired matching of perfusion and ventilation in heart failure detected by 133xenon.

Authors:  N P Lewis; A P Banning; J P Cooper; A S Sundar; P E Facey; W D Evans; A H Henderson
Journal:  Basic Res Cardiol       Date:  1996       Impact factor: 17.165

3.  Reduction of mismatch of global ventilation and perfusion on exercise is related to exercise capacity in chronic heart failure.

Authors:  N G Uren; S W Davies; J E Agnew; A G Irwin; S L Jordan; A J Hilson; D P Lipkin
Journal:  Br Heart J       Date:  1993-09

4.  Pattern of ventilation during exercise in chronic heart failure.

Authors:  K K A Witte; S D R Thackray; N P Nikitin; J G F Cleland; A L Clark
Journal:  Heart       Date:  2003-06       Impact factor: 5.994

5.  Static lung compliance in chronic heart failure: relation with dyspnoea and exercise capacity.

Authors:  S A Evans; L Watson; A J Cowley; I D Johnston; W J Kinnear
Journal:  Thorax       Date:  1995-03       Impact factor: 9.139

6.  Exercise ventilation after balloon dilatation of the mitral valve.

Authors:  A P Banning; N P Lewis; J S Elborn; R J Hall
Journal:  Br Heart J       Date:  1995-10
  6 in total