Literature DB >> 2929300

Early loss of fixation of femoral neck fractures. Comparison of three devices in 244 cases.

T Husby1, A Alho, L Nordsletten, W Bugge.   

Abstract

In successive series of displaced subcapital femoral neck fractures in the elderly, we operated on 75 cases with three Gouffon screws, 94 with three Mecron screws, and 75 with two von Bahr screws. Redisplacement within 3 months occurred in 20 Gouffon cases, 11 Mecron cases, and 12 von Bahr cases. Poor reduction contributed to the failures in all the groups. Although the reduction results in the three groups were similar, the Mecron group had better fixation and better social recovery than the Gouffon group. We concluded that, in addition to good reduction of the fracture, solid screws also contributed to the stability of the bone-implant construct.

Entities:  

Mesh:

Year:  1989        PMID: 2929300     DOI: 10.3109/17453678909150097

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  Undisplaced femoral neck fracture in the elderly.

Authors:  F Y Chiu; W H Lo
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

2.  Implant/bone constructs in femoral neck osteotomy. An autopsy study.

Authors:  J G Benterud; A Alho; A Höiseth
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

3.  Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study.

Authors:  Yunfeng Tang; Zhen Zhang; Limin Wang; Wei Xiong; Qian Fang; Guanglin Wang
Journal:  J Orthop Surg Res       Date:  2021-08-16       Impact factor: 2.359

4.  Biomechanics and indications for application of the method of BDSF. Answer to manuscript draft number AOTS-D- 17-00378, Letter to the Editor concerning ''Femoral neck fracture osteosynthesis by the biplane double-supported screw fixation method (BDSF) reduces the risk of fixation failure: clinical outcomes in 207 patients'' by Filipov O, Sommer C, et al. (2017) Arch Orthop Trauma Surg. Apr 8. [Epub ahead of print].

Authors:  Orlin Filipov; Karl Stoffel; Boyko Gueorguiev; Christoph Sommer
Journal:  Arch Orthop Trauma Surg       Date:  2017-06-30       Impact factor: 3.067

5.  Femoral neck fracture osteosynthesis by the biplane double-supported screw fixation method (BDSF) reduces the risk of fixation failure: clinical outcomes in 207 patients.

Authors:  Orlin Filipov; Karl Stoffel; Boyko Gueorguiev; Christoph Sommer
Journal:  Arch Orthop Trauma Surg       Date:  2017-04-08       Impact factor: 3.067

6.  Improved control over implant anchorage under the use of the femoral neck system for fixation of femoral neck fractures: a technical note.

Authors:  Yonghan Cha; Ji-Ung Song; Jun-Il Yoo; Ki Hoon Park; Jung-Taek Kim; Chan Ho Park; Won-Sik Choy
Journal:  BMC Musculoskelet Disord       Date:  2021-07-13       Impact factor: 2.362

7.  Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients.

Authors:  Bhava Rj Satish; Atmakuri V Ranganadham; Karruppasamy Ramalingam; Sujit Kumar Tripathy
Journal:  Indian J Orthop       Date:  2013-03       Impact factor: 1.251

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.