Evaluation of Several Electronic Glycemic Management Systems.

Narjes Alamri1, Jane Jeffrie Seley2.   

Abstract

Computerized insulin dosing software provides decision support in the form of pattern management identification, standardized dosing, and ease of use in both the inpatient and outpatient settings. The purpose of this analysis article is to review the features of all three electronic glycemic management systems available in the United States and to discuss the potential benefits of an automated insulin dosing system compared to a paper protocol or electronic order set. Four articles will be presented in this inpatient focused issue that examine the safety and efficacy of the Glytec® eGlycemic Management system in a variety of patient populations.

Entities:  

Keywords:  electronic glucose management system; glucose; inpatient; insulin

Mesh:

Substances:

Year:  2018        PMID: 29291649      PMCID: PMC5762001          DOI: 10.1177/1932296817751748

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  6 in total

1.  Comparison of Computer-Guided Versus Standard Insulin Infusion Regimens in Patients With Diabetic Ketoacidosis.

Authors:  Jagdeesh Ullal; Joseph A Aloi; David Reyes-Umpierrez; Francisco J Pasquel; Raymie McFarland; Marina Rabinovich; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2018-01

2.  Use of Decision Support Software to Titrate Multiple Daily Injections Yielded Sustained A1c Reductions After 1 Year.

Authors:  Bruce Bode; John G Clarke; Joseph Johnson
Journal:  J Diabetes Sci Technol       Date:  2017-12-17

3.  Risk of Hypoglycemia During Insulin Infusion Directed by Paper Protocol Versus Electronic Glycemic Management System in Critically Ill Patients at a Large Academic Medical Center.

Authors:  Marina Rabinovich; Jessica Grahl; Emily Durr; Rita Gayed; Katleen Chester; Raymie McFarland; Barbara McLean
Journal:  J Diabetes Sci Technol       Date:  2017-12-17

4.  Safely Converting an Entire Academic Medical Center From Sliding Scale to Basal Bolus Insulin via Implementation of the eGlycemic Management System.

Authors:  Rosalina Newsom; Christopher Patty; Emma Camarena; Regina Sawyer; Raymie McFarland; Thomas Gray; Melanie Mabrey
Journal:  J Diabetes Sci Technol       Date:  2017-12-13

5.  Comparison of an Electronic Glycemic Management System Versus Provider-Managed Subcutaneous Basal Bolus Insulin Therapy in the Hospital Setting.

Authors:  Joseph Aloi; Bruce W Bode; Jagdeesh Ullal; Paul Chidester; Raymie S McFarland; Amy E Bedingfield; Melanie Mabrey; Robby Booth; April Mumpower; Amisha Wallia
Journal:  J Diabetes Sci Technol       Date:  2016-09-25

6.  Standardized Glycemic Management with a Computerized Workflow and Decision Support System for Hospitalized Patients with Type 2 Diabetes on Different Wards.

Authors:  Katharina M Neubauer; Julia K Mader; Bernhard Höll; Felix Aberer; Klaus Donsa; Thomas Augustin; Lukas Schaupp; Stephan Spat; Peter Beck; Friedrich M Fruhwald; Christian Schnedl; Alexander R Rosenkranz; David B Lumenta; Lars-Peter Kamolz; Johannes Plank; Thomas R Pieber
Journal:  Diabetes Technol Ther       Date:  2015-06-05       Impact factor: 6.118

  6 in total
  4 in total

1.  Glucose Management Technologies for the Critically Ill.

Authors:  Pedro D Salinas; Carlos E Mendez
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

Review 2.  Subcutaneous Insulin Dosing Calculators for Inpatient Glucose Control.

Authors:  Jagdeesh Ullal; Joseph A Aloi
Journal:  Curr Diab Rep       Date:  2019-11-04       Impact factor: 4.810

3.  Insulin Infusion Computer Calculator Programmed Directly Into Electronic Health Record Medication Administration Record.

Authors:  Kristen Kulasa; Brittany Serences; Michael Nies; Robert El-Kareh; Kirk Kurashige; Kevin Box
Journal:  J Diabetes Sci Technol       Date:  2020-10-29

4.  Pathophysiologic Signature of Impending ICU Hypoglycemia in Bedside Monitoring and Electronic Health Record Data: Model Development and External Validation.

Authors:  William B Horton; Andrew J Barros; Robert T Andris; Matthew T Clark; J Randall Moorman
Journal:  Crit Care Med       Date:  2022-03-01       Impact factor: 7.598

  4 in total