Literature DB >> 29290898

First-in-man implantation of the retrievable and repositionable VenusA-Plus valve.

Xian-Bao Liu1, Yu-Xin He1, Chun-Hui Liu1, Li-Han Wang1, Feng Gao1, Lei Yu1, Ai-Qiang Dong2, Min-Jian Kong2, Ji-Fang Chen1, Yong Xu3, Qi-Jing Zhou4, Min Yan3, Jian-An Wang1.   

Abstract

BACKGROUND: No retrievable and repositionable second generation transcatheter aortic valve is available in China. Here, we report the first-in-man implantation of the retrievable and repositionable VenusA-Plus valve.
METHODS: A 76-year-old patient with symptomatic severe aortic stenosis and high surgical risk (STS 13.8%) was recommended for transcatheter aortic valve replacement (TAVR) by heart valve team. Type 0 bicuspid aortic valve with asymmetric calcification was identified by dual source computed tomography, and the unfavorable anatomies increased the possibility of malposition and paravalvular leakage during TAVR. Therefore, we used the retrievable and repositionable VenusA-Plus valve for the patient.
RESULTS: Transfemoral TAVR was performed under local anesthesia with sedation, and a 26mm VenusA-Plus valve was successfully implanted. No transvalvular pressure gradient and trace paravalvular leakage were found.
CONCLUSION: The successful first-in-man implantation indicates the retrievable and repositionable VenusA-Plus valve is feasible in complicated TAVR cases such as bicuspid aortic valve.

Entities:  

Keywords:  Bicuspid aortic valve; Repositionable; Retrievable; Transcatheter aortic valve replacement; VenusA-Plus valve

Year:  2018        PMID: 29290898      PMCID: PMC5717379          DOI: 10.5847/wjem.j.1920-8642.2018.01.010

Source DB:  PubMed          Journal:  World J Emerg Med        ISSN: 1920-8642


  4 in total

1.  Morphological characteristics of severe aortic stenosis in China: imaging corelab observations from the first Chinese transcatheter aortic valve trial.

Authors:  Hasan Jilaihawi; Yongjian Wu; Yuejin Yang; Liang Xu; Mao Chen; Jianan Wang; Xiangqing Kong; Ruiyan Zhang; Moyang Wang; Bin Lv; Wei Wang; Bo Xu; Raj R Makkar; Horst Sievert; Runlin Gao
Journal:  Catheter Cardiovasc Interv       Date:  2015-02-19       Impact factor: 2.692

2.  Evaluation of the safety and efficacy of transcatheter aortic valve implantation in patients with a severe stenotic bicuspid aortic valve in a Chinese population.

Authors:  Xian-bao Liu; Ju-bo Jiang; Qi-jing Zhou; Zhao-xia Pu; Wei He; Ai-qiang Dong; Yan Feng; Jun Jiang; Yong Sun; Mei-xiang Xiang; Yu-xin He; You-qi Fan; Liang Dong; Jian-an Wang
Journal:  J Zhejiang Univ Sci B       Date:  2015-03       Impact factor: 3.066

3.  2017 ESC/EACTS Guidelines for the management of valvular heart disease.

Authors:  Helmut Baumgartner; Volkmar Falk; Jeroen J Bax; Michele De Bonis; Christian Hamm; Per Johan Holm; Bernard Iung; Patrizio Lancellotti; Emmanuel Lansac; Daniel Rodriguez Muñoz; Raphael Rosenhek; Johan Sjögren; Pilar Tornos Mas; Alec Vahanian; Thomas Walther; Olaf Wendler; Stephan Windecker; Jose Luis Zamorano
Journal:  Eur Heart J       Date:  2017-09-21       Impact factor: 29.983

4.  Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis.

Authors:  Sung-Han Yoon; Sabine Bleiziffer; Ole De Backer; Victoria Delgado; Takahide Arai; Johannes Ziegelmueller; Marco Barbanti; Rahul Sharma; Gidon Y Perlman; Omar K Khalique; Erik W Holy; Smriti Saraf; Florian Deuschl; Buntaro Fujita; Philipp Ruile; Franz-Josef Neumann; Gregor Pache; Masao Takahashi; Hidehiro Kaneko; Tobias Schmidt; Yohei Ohno; Niklas Schofer; William K F Kong; Edgar Tay; Daisuke Sugiyama; Hiroyuki Kawamori; Yoshio Maeno; Yigal Abramowitz; Tarun Chakravarty; Mamoo Nakamura; Shingo Kuwata; Gerald Yong; Hsien-Li Kao; Michael Lee; Hyo-Soo Kim; Thomas Modine; S Chiu Wong; Francesco Bedgoni; Luca Testa; Emmanuel Teiger; Christian Butter; Stephan M Ensminger; Ulrich Schaefer; Danny Dvir; Philipp Blanke; Jonathon Leipsic; Fabian Nietlispach; Mohamed Abdel-Wahab; Bernard Chevalier; Corrado Tamburino; David Hildick-Smith; Brian K Whisenant; Seung-Jung Park; Antonio Colombo; Azeem Latib; Susheel K Kodali; Jeroen J Bax; Lars Søndergaard; John G Webb; Thierry Lefèvre; Martin B Leon; Raj Makkar
Journal:  J Am Coll Cardiol       Date:  2017-03-18       Impact factor: 24.094

  4 in total
  3 in total

1.  Effect of Eccentric Calcification of an Aortic Valve on the Implant Depth of a Venus-A Prosthesis During Transcatheter Aortic Valve Replacement: A Retrospective Study.

Authors:  Lanlan Li; Yang Liu; Ping Jin; Jiayou Tang; Linhe Lu; Guangyu Zhu; Chennian Xu; Yanyan Ma; Jian Yang
Journal:  Front Physiol       Date:  2021-08-06       Impact factor: 4.566

2.  The first two cases of transcatheter mitral valve repair with ARTO system in Asia.

Authors:  Kai-da Ren; Zhao-Xia Pu; Lei Yu; Feng Gao; Li-Han Wang; Stella Ng; Ju-Bo Jiang; Hua-Jun Li; Yong Xu; Wei He; Min Yan; Xian-Bao Liu; Jian-An Wang
Journal:  World J Emerg Med       Date:  2020

3.  Anatomical Predictors of Valve Malposition During Self-Expandable Transcatheter Aortic Valve Replacement.

Authors:  Jie Li; Yinghao Sun; Shengneng Zheng; Guang Li; Haojian Dong; Ming Fu; Yujing Mo; Yi Li; Huadong Liu; Zhaoyan Xu; Liting Zhang; Yong Cao; Ruixin Fan; D Scott Lim; Jianfang Luo
Journal:  Front Cardiovasc Med       Date:  2021-07-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.