Literature DB >> 29289433

Comparison between Several Ultrasound Hand Joint Scores and Conventional Radiography in Diagnosing Hand Osteoarthritis.

Priyanka Sivakumaran1, Sidra Hussain1, Coziana Ciurtin2.   

Abstract

This is the first study to investigate the usefulness of a standardized ultrasound (US) examination protocol in diagnosing hand osteoarthritis (OA). We conducted a cross-sectional study including 62 patients, ultimately diagnosed with hand OA based on imaging evidence of osteoarthritic changes with the particular distribution required for fulfilment of American College of Radiology diagnosis criteria. We compared a 32-joint US score (wrists, metacarpophalangeal [MCP], proximal interphalangeal [PIP] or distal interphalangeal [DIP] and carpometacarpal [CMC]-1 joints), with smaller, predefined joint scores, assessing 22 joints (wrists, MCPs and PIPs or PIPs, DIPs and CMC-1), 10 joints (MCP 2-3, PIP 2-3 and CMC-1 or PIP 2-3, DIP 2-3 and CMC-1) and 6 joints (DIP 2-3, CMC-1), respectively. The US findings were correlated with radiographic scores for erosions and osteophytes. Radiographic osteophyte scores correlated well with all the US scores mentioned earlier (R = 0.381 to 0.645, p < 0.05), despite low sensitivity for detection of osteophytes (43.5%) and erosions (28.9%), compared with the 32 joint US score. Both 10 joint US protocols (assessing MCP 2-3, PIP 2-3 and CMC-1 or PIP 2-3, DIP 2-3 and CMC-1 joints) performed better than conventional radiography, by identifying osteophytes in an additional 25.6% and 23.9% of patients, respectively. The conclusion of this study is that the US examination of 10 preselected hand joints is more sensitive than conventional radiography in diagnosing hand OA in patients who do not fulfill American College of Radiology clinical criteria, a finding likely to have practical implications for facilitating diagnosis of hand OA.
Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Conventional radiography; Hand osteoarthritis; Power doppler; Ultrasound

Mesh:

Year:  2017        PMID: 29289433     DOI: 10.1016/j.ultrasmedbio.2017.11.009

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

Review 1.  Turning the Page in Osteoarthritis Assessment with the Use of Ultrasound.

Authors:  Amanda E Nelson
Journal:  Curr Rheumatol Rep       Date:  2020-08-26       Impact factor: 4.592

2.  Reliability of detection of ultrasound and MRI features of hand osteoarthritis: a systematic review and meta-analysis.

Authors:  Abasiama D Obotiba; Subhashisa Swain; Jaspreet Kaur; Michael Doherty; Weiya Zhang; Abhishek Abhishek
Journal:  Rheumatology (Oxford)       Date:  2022-02-02       Impact factor: 7.580

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.