Literature DB >> 29288581

Comparison of Different-Gauge Needles for Fine-Needle Aspiration Biopsy of Thyroid Nodules.

Lili Zhang1, Yujiang Liu1, Xiaoqu Tan1, Xi Liu1, Hong Zhang1, Linxue Qian1.   

Abstract

OBJECTIVES: To compare the adequacy of 23-, 25-, and 27-gauge needles in the fine-needle aspiration biopsy of thyroid nodules to develop guidelines for the collection of better specimens for cytologic diagnosis.
METHODS: This randomized prospective study included 156 consecutively enrolled patients with 156 nodules. Each nodule was aspirated with a needle of each size. The obtained specimens were analyzed independently by 2 cytopathologists, and adequacy rates were calculated.
RESULTS: In our investigation, there were no statistically significant differences among the adequacy rates achieved with 23-, 25-, and 27-gauge needles (88.5%, 90.4%, and 89.7%, respectively; P > .05). The adequacy rates achieved with all 3 needle sizes in hyperechoic nodules were higher than those in hypoechoic samples (P < .05). Finally, no differences in adequacy for the different needle sizes were observed according to nodule size (P > .05).
CONCLUSIONS: We conclude that fine-needle aspiration biopsy with a 27-gauge needle can aspirate an adequate specimen for cytopathologic diagnosis of thyroid nodules. The likelihood that inadequate materials will be obtained from hypoechoic nodules is higher than that for hyperechoic nodules.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  adequacy; fine-needle aspiration biopsy; thyroid nodule; thyroid/parathyroid

Mesh:

Year:  2017        PMID: 29288581     DOI: 10.1002/jum.14521

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  6 in total

1.  Determining whether surgeons perform thyroid fine-needle aspiration as well as radiologists: an analysis of the adequacy and efficiency of ultrasound-guided fine-needle aspiration performed by newly trained head and neck surgeons and radiologists.

Authors:  Jiaxin Wang; Yanli Zhu; Yuntao Song; Guohui Xu; Hao Yu; Tianxiao Wang; Bin Zhang
Journal:  Gland Surg       Date:  2020-06

2.  Apropos of quality for fine-needle aspiration cytology of thyroid nodules with 22-, 23-, 25-, even 27-gauge needles and indeterminate cytology in thyroidology: an aide memory.

Authors:  Ilker Sengul; Demet Sengul
Journal:  Rev Assoc Med Bras (1992)       Date:  2022-08       Impact factor: 1.712

3.  Needle types used in abdominal cross-sectional interventional radiology: a survey of the Society of Abdominal Radiology emerging technology commission.

Authors:  Benjamin Wildman-Tobriner; Lisa M Ho; Andrew W Bowman
Journal:  Abdom Radiol (NY)       Date:  2021-06-14

4.  Ultrasound-Guided Fine Needle Aspiration of Deep Thyroid Nodule: Is There a Correlation between the Nodule's Depth and Nondiagnostic Results?

Authors:  Majd Asakly; Raed Farhat; Nidal El Khatib; Ashraf Khater; Alaa Safia; Marwan Karam; Saqer Massoud; Taiser Bishara; Yaniv Avraham; Adi Sharabi-Nov; Shlomo Merchavy
Journal:  J Thyroid Res       Date:  2022-08-29

5.  Comparison of Ultrasound-Guided Fine-Needle Cytology Quality in Thyroid Nodules with 22-, 23-, and 25-Gauge Needles.

Authors:  YiJie Dong; LiLi Gao; Yang Sui; MinJing Mao; WeiWei Zhan; JianQiao Zhou
Journal:  Anal Cell Pathol (Amst)       Date:  2021-06-07       Impact factor: 2.916

6.  Ultrasound-Guided Fine-Needle Aspiration Versus Fine-Needle Capillary Sampling in Evaluation of Lymph Node Metastasis of Thyroid Cancer.

Authors:  Shujun Xia; Yilai Chen; Weiwei Zhan; Wei Zhou
Journal:  Front Oncol       Date:  2021-04-14       Impact factor: 6.244

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.