Literature DB >> 29284096

Real-time Light Transmittance Monitoring for Determining Polymerization Completeness of Conventional and Bulk Fill Dental Composites.

M Par, I Repusic, H Skenderovic, E Klaric Sever, D Marovic, Z Tarle.   

Abstract

OBJECTIVES: To monitor the real-time changes in light transmittance during composite curing and to use transmittance data to determine the curing times required for a complete polymerization.
METHODS: Three conventional and three bulk fill composites were cured with two light-emitting diode curing units at layer thicknesses of 2 mm and 4 mm. The real-time light transmittance data were collected by a UV-Vis spectrometer in the wavelength range of 350-550 nm, plotted against time (t) and fitted to an exponential function f(t), whose first derivative ΔT(t) = df(t)/dt represented the rate of transmittance change. As the changing transmittance reflects structural changes that occur during polymerization, ΔT(t) > 0 was considered to indicate an ongoing polymerization, whereas ΔT(t) values approaching zero suggested a complete polymerization. This principle was used to determine times required for a complete polymerization (tcomplete) for each material/thickness/curing unit combination.
RESULTS: Light transmittance was significantly influenced by the material type, sample thickness, and curing unit, amounting to 2.9%-27.0% for the bulk fill and 0.7%-16.7% for the conventional composites. The values of tcomplete amounted to 15.3-23.3 seconds for the bulk fill composites at 2 mm, 20.2-33.3 seconds for the conventional composites at 2 mm, 26.9-42.1 seconds for the bulk fill composites at 4 mm, and 40.1-59.8 seconds for the conventional composites at 4 mm. Additionally, an exponential relationship was discovered between the light transmittance and tcomplete.
CONCLUSIONS: Some of the tcomplete values considerably exceeded the curing times recommended by the manufacturers.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29284096     DOI: 10.2341/17-041-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Temperature changes and hardness of resin-based composites light-cured with laser diode or light-emitting diode curing lights.

Authors:  Cristiane Maucoski; Richard Bengt Price; Cesar Augusto Galvão Arrais
Journal:  Odontology       Date:  2022-10-03       Impact factor: 2.885

2.  On the inaccuracies of dental radiometers.

Authors:  Adrian C Shortall; Mohammed A Hadis; William M Palin
Journal:  PLoS One       Date:  2021-01-29       Impact factor: 3.240

3.  Aging-Dependent Changes in Mechanical Properties of the New Generation of Bulk-Fill Composites.

Authors:  Danijela Marovic; Matej Par; Matea Macan; Nikolina Klarić; Iva Plazonić; Zrinka Tarle
Journal:  Materials (Basel)       Date:  2022-01-25       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.