Literature DB >> 29283177

Comparison of postoperative ultrasound criteria to predict unassisted use of arteriovenous fistulas for hemodialysis.

Timmy Lee1,2, Missy Magill3, Steven K Burke3, Andrew T Blair3, Michelle L Robbin4, Michael Allon1.   

Abstract

INTRODUCTION: Arteriovenous fistulas (AVF) frequently fail to mature. Postoperative ultrasounds provide objective measurements to predict unassisted AVF use for hemodialysis (unassisted use) and guide interventions to salvage nonmaturing AVFs. The optimal ultrasound criteria to assess AVF maturation are uncertain. We analyzed data from a multicenter, randomized, controlled, clinical trial to compare 2 published ultrasound maturation criteria used to predict unassisted AVF use for hemodialysis.
METHODS: We retrospectively analyzed prospective data on 105 patients undergoing new AVF creation, who underwent standardized postoperative ultrasounds at 6 and 12 weeks to measure AVF diameter and blood flow. Unassisted AVF use was defined as successful cannulation for ≥90 days without requiring prior surgical or percutaneous interventions. Two ultrasound criteria were assessed: (i) National Kidney Foundation (NKF) Kidney Disease Outcome Quality Initiative criteria: AVF outflow vein lumen diameter ≥6 mm and blood flow ≥600 mL/min; and (ii) University of Alabama at Birmingham (UAB) criteria: AVF outflow vein lumen diameter ≥4 mm and blood flow ≥500 mL/min. Performance characteristics were calculated for both criteria.
RESULTS: Compared to the NKF criteria, the UAB criteria had a higher sensitivity (89 vs.68%), but a lower specificity (42 vs. 70%) for unassisted AVF use. For radiocephalic AVFs, the UAB criteria had higher sensitivity (86 vs. 46%) and lower specificity (58 vs. 83%). For brachiocephalic AVFs, both UAB and NKF had high sensitivity (90 and 80%) but low specificity (21 and 53%), respectively.
CONCLUSIONS: Using the UAB ultrasound criteria would minimize unnecessary early interventions in AVFs likely to mature without an intervention, but would delay interventions in AVFs that are unlikely to mature. The UAB criteria may be preferred in patients receiving a radiocephalic AVF.

Entities:  

Keywords:  Arteriovenous fistula; Hemodialysis; Ultrasound

Mesh:

Year:  2018        PMID: 29283177     DOI: 10.5301/jva.5000818

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  3 in total

1.  Postoperative Ultrasound, Unassisted Maturation, and Subsequent Primary Patency of Arteriovenous Fistulas.

Authors:  Crystal A Farrington; Michelle L Robbin; Timmy Lee; Jill Barker-Finkel; Michael Allon
Journal:  Clin J Am Soc Nephrol       Date:  2018-08-23       Impact factor: 8.237

2.  Early Predictors of Arteriovenous Fistula Maturation: A Novel Perspective on an Enduring Problem.

Authors:  Crystal A Farrington; Michelle L Robbin; Timmy Lee; Jill Barker-Finkel; Michael Allon
Journal:  J Am Soc Nephrol       Date:  2020-05-18       Impact factor: 10.121

3.  Ultrasound evaluation of percutaneously created arteriovenous fistulae between radial artery and perforating vein at the elbow.

Authors:  Gilbert Franco; Alexandros Mallios; Pierre Bourquelot; William Jennings; Benoit Boura
Journal:  J Vasc Access       Date:  2020-01-10       Impact factor: 2.283

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.