| Literature DB >> 29279626 |
K Jayaprakash1, K Harish Kumar Shetty2, A Nityananda Shetty3, Bantarahalli Thopegowda Nandish1.
Abstract
AIM: The aim of this study was to quantitatively estimate the concentration of ion release from recasted base metal alloys in various pH conditions using atomic absorption spectroscopy (AAS).Entities:
Keywords: Artificial saliva; cobalt-chromium; ion release; nickel-chromium; recycling; saline solution
Year: 2017 PMID: 29279626 PMCID: PMC5706323 DOI: 10.4103/0972-0707.218304
Source DB: PubMed Journal: J Conserv Dent ISSN: 0972-0707
Composition and weight percentage of four commercially available casting alloys used in the study
Quantities of ion released from cobalt-chromium Wirobond C alloy in artificial saliva at pH 2.3
Quantities of ion released from nickel-chromium Wirolloy in 0.9% saline solution at pH 7.3
Quantities of ion released from cobalt-chromium Wirobond C alloy in artificial saliva at pH 6.7
Quantities of ion released from cobalt-chromium Wirobond C alloy in 0.9% saline solution at pH 7.3
Quantities of ion released from nickel-chromium Wirolloy in artificial saliva at pH 2.3
Quantities of ion released from nickel-chromium Wirolloy in artificial saliva at pH 6.7