Literature DB >> 29278354

Long-term clinical outcomes of a crystalline sirolimus-eluting coronary stent with a fully bioabsorbable polymer coating: five-year outcomes from the DESSOLVE I and II trials.

William Wijns1, Mathias Vrolix, Stefan Verheye, Danny Schoors, Ton Slagboom, Marcel Gosselink, Edouard Benit, David Kandzari, Dennis Donohoe, John A Ormiston.   

Abstract

AIMS: The aim of this study was to evaluate the five-year clinical results of a sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for sustained drug delivery during and after rapid polymer dissolution. METHODS AND
RESULTS: The five-year results from the DESSOLVE I and II trials including major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at five-year follow-up are reported. In DESSOLVE I, 10.3% of patients receiving the MiStent SES (3/29) had a MACE event up to five years without TLF. In DESSOLVE II, 15.1% of patients in the MiStent group (18/119) had a five-year MACE event compared to 22.0% of patients in the Endeavor group (p=0.295). TLF was 9.2% in the MiStent group and 8.5% in the Endeavor group (p=1.00). TVF was 10.1% for MiStent versus 15.3% for Endeavor (p=0.331). Up to five-year follow-up, the MiStent SES has continued to demonstrate low rates of TLR across DESSOLVE I (0.0%) and DESSOLVE II (3.4%). No ST was reported with the MiStent up to five years in the DESSOLVE I trial. In DESSOLVE II, definite or probable ST was 0.0% with MiStent and 1.7% with Endeavor up to five years.
CONCLUSIONS: The MiStent SES demonstrated long-term safety and effectiveness with low rates of five-year MACE, TLF, and TVF across these two clinical trials.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29278354     DOI: 10.4244/EIJ-D-17-00230

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  4 in total

1.  Defining drug and target protein distributions after stent-based drug release: Durable versus deployable coatings.

Authors:  Abraham R Tzafriri; Fernando Garcia-Polite; Xiaojian Li; John Keating; Josep-Maria Balaguer; Brett Zani; Lynn Bailey; Peter Markham; Timothy C Kiorpes; Wenda Carlyle; Elazer R Edelman
Journal:  J Control Release       Date:  2018-02-05       Impact factor: 9.776

2.  Development of Multifunctional Commercial Pure Titanium-Polyethylene Glycol Drug-Eluting Substrates with Enhanced Optical and Antithrombotic Properties.

Authors:  Monalisha Mohanta; A Thirugnanam
Journal:  Cardiovasc Eng Technol       Date:  2022-06-14       Impact factor: 2.495

3.  Long-term follow-up after ultrathin vs. conventional 2nd-generation drug-eluting stents: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Mahesh V Madhavan; James P Howard; Azim Naqvi; Ori Ben-Yehuda; Bjorn Redfors; Megha Prasad; Bahira Shahim; Martin B Leon; Sripal Bangalore; Gregg W Stone; Yousif Ahmad
Journal:  Eur Heart J       Date:  2021-07-15       Impact factor: 29.983

4.  Clinical Outcomes of World's Thinnest (50 μmr) Strut Biodegradable Polymer Coated Everolimus-Eluting Coronary Stent System in Real-World Patients.

Authors:  Suresh V Patted; Anmol Suresh Patted; Prakash Kumar Turiya; Ashok S Thakkar
Journal:  Cardiol Res       Date:  2018-12-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.