Double-Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging.

Moein Mozaffarzadeh1, Masume Sadeghi1, Ali Mahloojifar2, Mahdi Orooji1.   

Abstract

In ultrasound (US) imaging, delay and sum (DAS) is the most common beamformer, but it leads to low-quality images. Delay multiply and sum (DMAS) was introduced to address this problem. However, the reconstructed images using DMAS still suffer from the level of side lobes and low noise suppression. Here, a novel beamforming algorithm is introduced based on expansion of the DMAS formula. We found that there is a DAS algebra inside the expansion, and we proposed use of the DMAS instead of the DAS algebra. The introduced method, namely double-stage DMAS (DS-DMAS), is evaluated numerically and experimentally. The quantitative results indicate that DS-DMAS results in an approximately 25% lower level of side lobes compared with DMAS. Moreover, the introduced method leads to 23%, 22% and 43% improvement in signal-to-noise ratio, full width at half-maximum and contrast ratio, respectively, compared with the DMAS beamformer.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Keywords:  Beamforming; Contrast improvement; Delay multiply and sum; Linear-array imaging; Resolution enhancement; Ultrasound medical imaging

Mesh:

Year:  2017        PMID: 29276138     DOI: 10.1016/j.ultrasmedbio.2017.10.020

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  7 in total

1.  Minimum variance beamforming combined with covariance matrix-based adaptive weighting for medical ultrasound imaging.

Authors:  Yuanguo Wang; Yadan Wang; Mingzhou Liu; Zhengfeng Lan; Chichao Zheng; Hu Peng
Journal:  Biomed Eng Online       Date:  2022-06-18       Impact factor: 3.903

2.  Image improvement in linear-array photoacoustic imaging using high resolution coherence factor weighting technique.

Authors:  Moein Mozaffarzadeh; Bahador Makkiabadi; Maryam Basij; Mohammad Mehrmohammadi
Journal:  BMC Biomed Eng       Date:  2019-04-05

3.  Enhanced contrast acoustic-resolution photoacoustic microscopy using double-stage delay-multiply-and-sum beamformer for vasculature imaging.

Authors:  Moein Mozaffarzadeh; Mehdi H H Varnosfaderani; Arunima Sharma; Manojit Pramanik; Nico de Jong; Martin D Verweij
Journal:  J Biophotonics       Date:  2019-08-07       Impact factor: 3.207

4.  Optimally-weighted non-linear beamformer for conventional focused beam ultrasound imaging systems.

Authors:  Anudeep Vayyeti; Arun K Thittai
Journal:  Sci Rep       Date:  2021-11-03       Impact factor: 4.379

Review 5.  Achieving depth-independent lateral resolution in AR-PAM using the synthetic-aperture focusing technique.

Authors:  Rongkang Gao; Qiang Xue; Yaguang Ren; Hai Zhang; Liang Song; Chengbo Liu
Journal:  Photoacoustics       Date:  2021-12-24

6.  The double-stage delay-multiply-and-sum image reconstruction method improves imaging quality in a LED-based photoacoustic array scanner.

Authors:  Moein Mozaffarzadeh; Ali Hariri; Colman Moore; Jesse V Jokerst
Journal:  Photoacoustics       Date:  2018-09-18

7.  Microwave Breast Imaging Using Compressed Sensing Approach of Iteratively Corrected Delay Multiply and Sum Beamforming.

Authors:  Mohammad Tariqul Islam; Md Tarikul Islam; Md Samsuzzaman; Salehin Kibria; Muhammad E H Chowdhury
Journal:  Diagnostics (Basel)       Date:  2021-03-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.