Literature DB >> 29275031

The Diagnostic Accuracy of Fractional Exhaled Nitric Oxide Testing in Asthma: A Systematic Review and Meta-analyses.

Zhen Wang1, Paolo T Pianosi2, Karina A Keogh3, Feras Zaiem4, Mouaz Alsawas4, Fares Alahdab4, Jehad Almasri4, Khaled Mohammed4, Laura Larrea-Mantilla4, Wigdan Farah4, Lubna Daraz4, Patricia Barrionuevo4, Allison S Morrow4, Larry J Prokop5, Mohammad Hassan Murad6.   

Abstract

OBJECTIVE: To evaluate the diagnostic accuracy of fractional exhaled nitric oxide (FeNO) measurement in individuals with suspected asthma.
METHODS: We searched MEDLINE, EMBASE, PsycINFO, Cochrane databases, and SciVerse Scopus from the databases' inception through April 4, 2017, for studies that enrolled patients aged 5 years and older with suspected asthma and evaluated FeNO diagnostic accuracy. Independent reviewers selected studies and extracted data. We used the symmetric hierarchical summary receiver operating characteristic models to estimate test performance.
RESULTS: We included 43 studies with a total of 13,747 patients. In adults, using FeNO cutoffs of less than 20, 20 to 29, 30 to 39, and 40 or more parts per billion, FeNO testing had sensitivities of 0.80, 0.69, 0.53, and 0.41, respectively, and specificities of 0.64, 0.78, 0.85, and 0.93, respectively. In children, using FeNO cutoffs of less than 20 and 20 to 29 parts per billion, FeNO testing had sensitivities of 0.78 and 0.61, respectively, and specificities of 0.79 and 0.89, respectively. Depending on the FeNO cutoff, the posttest odds of having asthma with a positive FeNO test result increased by 2.80- to 7.00-fold. Diagnostic accuracy was modestly better in corticosteroid-naive asthmatics, children, and nonsmokers than in the overall population.
CONCLUSION: Fractional exhaled nitric oxide measurement has moderate accuracy to diagnose asthma in individuals aged 5 years and older. Test performance may be modestly better in corticosteroid-naive asthmatics, children, and nonsmokers than in the general population with suspected asthma. TRIAL REGISTRATION: International Prospective Register of Systematic Reviews (PROSPERO) Identifier: CRD42016047887.
Copyright © 2017 Mayo Foundation for Medical Education and Research. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29275031     DOI: 10.1016/j.mayocp.2017.11.012

Source DB:  PubMed          Journal:  Mayo Clin Proc        ISSN: 0025-6196            Impact factor:   7.616


  8 in total

1.  Ability of Exhaled Nitric Oxide to Discriminate for Airflow Obstruction Among Frequent Exacerbators of Clinically Diagnosed Asthma.

Authors:  Leena Jalota; D Richard Allison; Vinisha Prajapati; Jose J Vempilly; Vipul V Jain
Journal:  Lung       Date:  2018-06-18       Impact factor: 2.584

Review 2.  What is New in the Management of Childhood Asthma?

Authors:  Atul Gupta; Gayathri Bhat; Paolo Pianosi
Journal:  Indian J Pediatr       Date:  2018-06-09       Impact factor: 1.967

Review 3.  Clinical utility of exhaled nitric oxide fraction in the management of asthma and COPD.

Authors:  Steve W Turner; Anne B Chang; Ian A Yang
Journal:  Breathe (Sheff)       Date:  2019-12

4.  Clinical Features of Chronic Obstructive Pulmonary Disease with High Fractional Exhaled Nitric Oxide.

Authors:  Seong Ahn; Tae-Ok Kim; Jinsun Chang; Hong-Joon Shin; Yong-Soo Kwon; Sung-Chul Lim; Yu-Il Kim
Journal:  Tuberc Respir Dis (Seoul)       Date:  2020-06-18

5.  Nitric oxide in occurrence, progress and therapy of lung Cancer: a systemic review and meta-analysis.

Authors:  Hongbin Zhou; Jiuke Li; Zhewen Chen; Ying Chen; Sa Ye
Journal:  BMC Cancer       Date:  2021-06-08       Impact factor: 4.430

6.  Pneumomediastinum, Tracheal Diverticulum, and Probable Asthma: Coincidence or Possible Association? A Case Report.

Authors:  Ivan Cherrez-Ojeda; Miguel Felix; Emanuel Vanegas; Valeria L Mata
Journal:  Am J Case Rep       Date:  2018-10-25

7.  Performance of fractional exhaled nitric oxide in predicting response to inhaled corticosteroids in chronic cough: a meta-analysis.

Authors:  Pasquale Ambrosino; Mariasofia Accardo; Marco Mosella; Antimo Papa; Salvatore Fuschillo; Giorgio Alfredo Spedicato; Andrea Motta; Mauro Maniscalco
Journal:  Ann Med       Date:  2021-12       Impact factor: 4.709

8.  Diagnostic possibility of the combination of exhaled nitric oxide and blood eosinophil count for eosinophilic asthma.

Authors:  Jiang-Hua Li; Rui Han; Yu-Bo Wang; Min Cheng; Heng-Yi Chen; Wen-Hui Lei; Li Li; Chen Gao; Na-Na Zhao; Nai-Fu Nie; Zhong-Yan Li; Guo-Qing Yin; Shuai Huang; Yong He
Journal:  BMC Pulm Med       Date:  2021-08-09       Impact factor: 3.317

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.