Literature DB >> 29268175

Background electrolytes and pH effects on selenate adsorption using iron-impregnated granular activated carbon and surface binding mechanisms.

Ning Zhang1, Daniel Dianchen Gang2, Louis McDonald3, Lian-Shin Lin4.   

Abstract

Iron-impregnated granular activated carbon (Fe-GAC) has been shown effective for selenite adsorptive removal from aqueous solutions, but similar effectiveness was not observed with selenate. This study examined the effects of background electrolytes and pH on selenate adsorption on to Fe-GAC, and surface bindings to elucidate the selenate adsorption mechanisms. The decrease magnitude of selenate adsorption capacity under three background electrolytes followed the order: LiCl > NaCl > KCl, as ionic strength increased from 0.01 to 0.1 M. Larger adsorption capacity differences among the three electrolytes were observed under the higher ionic strengths (0.05 and 0.1 M) than those under 0.01 M. Multiplet peak fittings of high resolution X-ray photoelectron spectra for O1s and Fe2p3/2 indicated the presence of iron (III) on adsorbent surface. pH variations during the adsorbent preparation within 3-8 in NaCl solutions did not cause appreciable changes in the iron redox state and composition. Raman spectra showed the formation of both monodentate and bidentate inner sphere complexes under pHs <7 and a mixture of outer sphere and inner sphere complexes at pH 8. These results explained the lower selenate adsorption under alkaline conditions. Mechanisms for monodentate and bidentate formations and a stable six-member ring structure were proposed. Two strategies were recommended for modifying Fe-GAC preparation procedure to enhance the selenate adsorption: (1) mixed-metal oxide coatings to increase the point of zero charge (pHzpc); and (2) ferrous iron coating to initially reduce selenate followed by selenite adsorption.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Adsorption mechanisms; Electrolytes; Raman; Selenate adsorption; X-ray photoelectron analysis

Mesh:

Substances:

Year:  2017        PMID: 29268175     DOI: 10.1016/j.chemosphere.2017.11.161

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  1 in total

1.  Enhanced Selenate Removal in Aqueous Phase by Copper-Coated Activated Carbon.

Authors:  Xinhai Zhao; Aiqing Zhang; Jianhong Zhang; Qipeng Wang; Xuquan Huang; Yonghong Wu; Cilai Tang
Journal:  Materials (Basel)       Date:  2020-01-19       Impact factor: 3.623

  1 in total